Claudio Bonizzoni, Maksut Maksutoglu, Alberto Ghirri, Johan van Tol, Bulat Rameev, Marco Affronte
{"title":"亚纳升BDPA有机自由基自旋综与YBCO逆模拟谐振腔的耦合","authors":"Claudio Bonizzoni, Maksut Maksutoglu, Alberto Ghirri, Johan van Tol, Bulat Rameev, Marco Affronte","doi":"10.1007/s00723-022-01505-8","DOIUrl":null,"url":null,"abstract":"<div><p>We report the development and test of planar microwave Inverse Anapole Resonators (IARs) made of superconducting Yttrium Barium Copper Oxide (YBCO) for electron spin resonance spectroscopy on small samples. We first characterize our resonators in zero field and then by carrying out transmission spectroscopy on a diluted <span>\\(\\alpha ,\\gamma \\)</span>-bisdiphenylene-<span>\\(\\beta \\)</span>-phenylally (BDPA) organic radical spin ensemble in an applied magnetic field. These IARs allow us to carry out electron spin resonance spectroscopy both in continuous-wave and pulsed-wave mode, and to estimate the spin memory time of BDPA. The comparison with the results obtained for the same sample on typical linear coplanar resonators shows an improvement by <span>\\(\\approx 2\\text { - up to}\\,3\\)</span> – orders of magnitude in spin sensitivity, with effective sensing volumes below 1 nanoliter. The best sensitivity we achieved is <span>\\(S\\approx \\,10^{7}\\,\\text {spin}/\\sqrt{\\mathrm{Hz}}\\)</span> in the pulsed-wave regime. These results compare well with similar experiments reported in the literature.</p></div>","PeriodicalId":469,"journal":{"name":"Applied Magnetic Resonance","volume":"54 1","pages":"143 - 164"},"PeriodicalIF":1.1000,"publicationDate":"2022-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Coupling Sub-nanoliter BDPA Organic Radical Spin Ensembles with YBCO Inverse Anapole Resonators\",\"authors\":\"Claudio Bonizzoni, Maksut Maksutoglu, Alberto Ghirri, Johan van Tol, Bulat Rameev, Marco Affronte\",\"doi\":\"10.1007/s00723-022-01505-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>We report the development and test of planar microwave Inverse Anapole Resonators (IARs) made of superconducting Yttrium Barium Copper Oxide (YBCO) for electron spin resonance spectroscopy on small samples. We first characterize our resonators in zero field and then by carrying out transmission spectroscopy on a diluted <span>\\\\(\\\\alpha ,\\\\gamma \\\\)</span>-bisdiphenylene-<span>\\\\(\\\\beta \\\\)</span>-phenylally (BDPA) organic radical spin ensemble in an applied magnetic field. These IARs allow us to carry out electron spin resonance spectroscopy both in continuous-wave and pulsed-wave mode, and to estimate the spin memory time of BDPA. The comparison with the results obtained for the same sample on typical linear coplanar resonators shows an improvement by <span>\\\\(\\\\approx 2\\\\text { - up to}\\\\,3\\\\)</span> – orders of magnitude in spin sensitivity, with effective sensing volumes below 1 nanoliter. The best sensitivity we achieved is <span>\\\\(S\\\\approx \\\\,10^{7}\\\\,\\\\text {spin}/\\\\sqrt{\\\\mathrm{Hz}}\\\\)</span> in the pulsed-wave regime. These results compare well with similar experiments reported in the literature.</p></div>\",\"PeriodicalId\":469,\"journal\":{\"name\":\"Applied Magnetic Resonance\",\"volume\":\"54 1\",\"pages\":\"143 - 164\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2022-11-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Magnetic Resonance\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00723-022-01505-8\",\"RegionNum\":4,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSICS, ATOMIC, MOLECULAR & CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Magnetic Resonance","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s00723-022-01505-8","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, ATOMIC, MOLECULAR & CHEMICAL","Score":null,"Total":0}
We report the development and test of planar microwave Inverse Anapole Resonators (IARs) made of superconducting Yttrium Barium Copper Oxide (YBCO) for electron spin resonance spectroscopy on small samples. We first characterize our resonators in zero field and then by carrying out transmission spectroscopy on a diluted \(\alpha ,\gamma \)-bisdiphenylene-\(\beta \)-phenylally (BDPA) organic radical spin ensemble in an applied magnetic field. These IARs allow us to carry out electron spin resonance spectroscopy both in continuous-wave and pulsed-wave mode, and to estimate the spin memory time of BDPA. The comparison with the results obtained for the same sample on typical linear coplanar resonators shows an improvement by \(\approx 2\text { - up to}\,3\) – orders of magnitude in spin sensitivity, with effective sensing volumes below 1 nanoliter. The best sensitivity we achieved is \(S\approx \,10^{7}\,\text {spin}/\sqrt{\mathrm{Hz}}\) in the pulsed-wave regime. These results compare well with similar experiments reported in the literature.
期刊介绍:
Applied Magnetic Resonance provides an international forum for the application of magnetic resonance in physics, chemistry, biology, medicine, geochemistry, ecology, engineering, and related fields.
The contents include articles with a strong emphasis on new applications, and on new experimental methods. Additional features include book reviews and Letters to the Editor.