液相色谱-串联质谱法测定血清中睾酮。

U Turpeinen, S Linko, O Itkonen, E Hämäläinen
{"title":"液相色谱-串联质谱法测定血清中睾酮。","authors":"U Turpeinen,&nbsp;S Linko,&nbsp;O Itkonen,&nbsp;E Hämäläinen","doi":"10.1080/00365510701496496","DOIUrl":null,"url":null,"abstract":"<p><p>Commercial direct immunoassays for serum testosterone sometimes result in inaccuracies in samples from women and children, leading to misdiagnosis and inappropriate treatment. The diagnosis of male hypogonadism also requires an accurate testosterone assay method. We therefore developed a sensitive and specific stable-isotope dilution liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for serum testosterone at the concentrations encountered in women and children. Testosterone was extracted with ether-ethyl acetate from 250 microL or 500 microL of serum. Instrumental analysis was performed on an API 2000 tandem mass spectrometer in the multiple-reaction monitoring (MRM) mode after separation on a reversed-phase column. The MRM transitions (m/z) were 289/97 for testosterone and 291/99 for d(2) testosterone. The calibration curves exhibited consistent linearity and repeatability in the range 0.2-100 nmol/L. Interassay CVs were 4.2-7.6 % at mean concentrations of testosterone of 3.3-45 nmol/L. Total measurement uncertainty (U, k = 2) was 12.9 % and 13.4 % at testosterone levels of 2.0 nmol/L and 20 nmol/L, respectively. The limit of detection was 0.05 nmol/L (signal-to-noise ratio = 3) and the overall method recovery of testosterone was 95 %. Correlation (r) with our in-house extraction RIA was 0.98 and with a commercial RIA 0.92. Reference intervals for adult males and females in age groups 18-30, 31-50, 51-70 and over 70 years were established. Sensitivity and specificity of the LC-MS/MS method offer advantages over immunoassay and make it suitable for use as a high-throughput assay in routine clinical laboratories. The high equipment costs are balanced by higher throughput together with shorter chromatographic run times.</p>","PeriodicalId":501634,"journal":{"name":"Scandinavian Journal of Clinical and Laboratory Investigation","volume":" ","pages":"50-7"},"PeriodicalIF":0.0000,"publicationDate":"2008-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00365510701496496","citationCount":"71","resultStr":"{\"title\":\"Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry.\",\"authors\":\"U Turpeinen,&nbsp;S Linko,&nbsp;O Itkonen,&nbsp;E Hämäläinen\",\"doi\":\"10.1080/00365510701496496\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Commercial direct immunoassays for serum testosterone sometimes result in inaccuracies in samples from women and children, leading to misdiagnosis and inappropriate treatment. The diagnosis of male hypogonadism also requires an accurate testosterone assay method. We therefore developed a sensitive and specific stable-isotope dilution liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for serum testosterone at the concentrations encountered in women and children. Testosterone was extracted with ether-ethyl acetate from 250 microL or 500 microL of serum. Instrumental analysis was performed on an API 2000 tandem mass spectrometer in the multiple-reaction monitoring (MRM) mode after separation on a reversed-phase column. The MRM transitions (m/z) were 289/97 for testosterone and 291/99 for d(2) testosterone. The calibration curves exhibited consistent linearity and repeatability in the range 0.2-100 nmol/L. Interassay CVs were 4.2-7.6 % at mean concentrations of testosterone of 3.3-45 nmol/L. Total measurement uncertainty (U, k = 2) was 12.9 % and 13.4 % at testosterone levels of 2.0 nmol/L and 20 nmol/L, respectively. The limit of detection was 0.05 nmol/L (signal-to-noise ratio = 3) and the overall method recovery of testosterone was 95 %. Correlation (r) with our in-house extraction RIA was 0.98 and with a commercial RIA 0.92. Reference intervals for adult males and females in age groups 18-30, 31-50, 51-70 and over 70 years were established. Sensitivity and specificity of the LC-MS/MS method offer advantages over immunoassay and make it suitable for use as a high-throughput assay in routine clinical laboratories. The high equipment costs are balanced by higher throughput together with shorter chromatographic run times.</p>\",\"PeriodicalId\":501634,\"journal\":{\"name\":\"Scandinavian Journal of Clinical and Laboratory Investigation\",\"volume\":\" \",\"pages\":\"50-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/00365510701496496\",\"citationCount\":\"71\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian Journal of Clinical and Laboratory Investigation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/00365510701496496\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2007/6/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical and Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365510701496496","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2007/6/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 71

摘要

商业性的血清睾酮直接免疫测定法有时会导致妇女和儿童样本的不准确,从而导致误诊和不当治疗。男性性腺功能减退症的诊断也需要精确的睾酮测定方法。因此,我们开发了一种灵敏、特异的稳定同位素稀释液相色谱-串联质谱(LC-MS/MS)方法,用于检测妇女和儿童血清睾酮浓度。用乙酸乙酯从250微升或500微升的血清中提取睾酮。反相柱分离后,在API 2000串联质谱仪上进行多反应监测(MRM)模式的仪器分析。睾酮和d(2)睾酮的MRM转换(m/z)分别为289/97和291/99。标定曲线在0.2 ~ 100 nmol/L范围内线性一致,重复性好。睾酮平均浓度为3.3-45 nmol/L时,试验间CVs为4.2- 7.6%。在睾酮水平为2.0 nmol/L和20 nmol/L时,总测量不确定度(U, k = 2)分别为12.9%和13.4%。检测限为0.05 nmol/L(信噪比为3),睾酮的总回收率为95%。与我们的内部提取RIA的相关性(r)为0.98,与商业RIA的相关性(r)为0.92。建立了18-30岁、31-50岁、51-70岁和70岁以上成年男女的参考区间。LC-MS/MS方法的灵敏度和特异性优于免疫分析法,使其适合作为常规临床实验室的高通量测定方法。高通量和较短的色谱运行时间平衡了高设备成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry.

Commercial direct immunoassays for serum testosterone sometimes result in inaccuracies in samples from women and children, leading to misdiagnosis and inappropriate treatment. The diagnosis of male hypogonadism also requires an accurate testosterone assay method. We therefore developed a sensitive and specific stable-isotope dilution liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for serum testosterone at the concentrations encountered in women and children. Testosterone was extracted with ether-ethyl acetate from 250 microL or 500 microL of serum. Instrumental analysis was performed on an API 2000 tandem mass spectrometer in the multiple-reaction monitoring (MRM) mode after separation on a reversed-phase column. The MRM transitions (m/z) were 289/97 for testosterone and 291/99 for d(2) testosterone. The calibration curves exhibited consistent linearity and repeatability in the range 0.2-100 nmol/L. Interassay CVs were 4.2-7.6 % at mean concentrations of testosterone of 3.3-45 nmol/L. Total measurement uncertainty (U, k = 2) was 12.9 % and 13.4 % at testosterone levels of 2.0 nmol/L and 20 nmol/L, respectively. The limit of detection was 0.05 nmol/L (signal-to-noise ratio = 3) and the overall method recovery of testosterone was 95 %. Correlation (r) with our in-house extraction RIA was 0.98 and with a commercial RIA 0.92. Reference intervals for adult males and females in age groups 18-30, 31-50, 51-70 and over 70 years were established. Sensitivity and specificity of the LC-MS/MS method offer advantages over immunoassay and make it suitable for use as a high-throughput assay in routine clinical laboratories. The high equipment costs are balanced by higher throughput together with shorter chromatographic run times.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信