对假体过敏。

Visnja Milavec-Puretić
{"title":"对假体过敏。","authors":"Visnja Milavec-Puretić","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This paper describes a study of hypersensitivity and tissue reaction to loosened metal implants in 40 patients who underwent repeated hip arthroplasty. Metal sensitivity was tested using a standard cutaneous patch test. Nine patients were positive for chromium, nickel, cobalt, metal rust, endoprosthesis scrapings or combinations of these allergens. Patients with positive or negative patch test did not differ in terms of their age, sex, primary diagnosis, number of endoprosthesis revisions, length of implant function, presence of other metal parts around the implant, circulating immunocomplexes, and histological appearance of the tissue around the implant. In conclusion, stainless steel endoprostheses are safe for revised hip arthroplasty, and hypersensitivity to metals probably does not play a significant role in the loosening of endoprosthesis.</p>","PeriodicalId":520565,"journal":{"name":"Arhiv za higijenu rada i toksikologiju","volume":" ","pages":"193-6"},"PeriodicalIF":0.0000,"publicationDate":"2004-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Allergy to endoprostheses.\",\"authors\":\"Visnja Milavec-Puretić\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper describes a study of hypersensitivity and tissue reaction to loosened metal implants in 40 patients who underwent repeated hip arthroplasty. Metal sensitivity was tested using a standard cutaneous patch test. Nine patients were positive for chromium, nickel, cobalt, metal rust, endoprosthesis scrapings or combinations of these allergens. Patients with positive or negative patch test did not differ in terms of their age, sex, primary diagnosis, number of endoprosthesis revisions, length of implant function, presence of other metal parts around the implant, circulating immunocomplexes, and histological appearance of the tissue around the implant. In conclusion, stainless steel endoprostheses are safe for revised hip arthroplasty, and hypersensitivity to metals probably does not play a significant role in the loosening of endoprosthesis.</p>\",\"PeriodicalId\":520565,\"journal\":{\"name\":\"Arhiv za higijenu rada i toksikologiju\",\"volume\":\" \",\"pages\":\"193-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arhiv za higijenu rada i toksikologiju\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arhiv za higijenu rada i toksikologiju","FirstCategoryId":"3","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文描述了40例重复髋关节置换术患者对松动金属植入物的过敏和组织反应的研究。使用标准皮肤贴片试验测试金属敏感性。9例患者对铬、镍、钴、金属锈、假体刮伤或这些过敏原的组合呈阳性。贴片试验阳性或阴性的患者在年龄、性别、初次诊断、假体修复次数、假体功能长度、假体周围其他金属部件的存在、循环免疫复合物和假体周围组织的组织学外观方面没有差异。综上所述,不锈钢假体用于改良髋关节置换术是安全的,对金属的过敏可能不是假体松动的主要原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Allergy to endoprostheses.

This paper describes a study of hypersensitivity and tissue reaction to loosened metal implants in 40 patients who underwent repeated hip arthroplasty. Metal sensitivity was tested using a standard cutaneous patch test. Nine patients were positive for chromium, nickel, cobalt, metal rust, endoprosthesis scrapings or combinations of these allergens. Patients with positive or negative patch test did not differ in terms of their age, sex, primary diagnosis, number of endoprosthesis revisions, length of implant function, presence of other metal parts around the implant, circulating immunocomplexes, and histological appearance of the tissue around the implant. In conclusion, stainless steel endoprostheses are safe for revised hip arthroplasty, and hypersensitivity to metals probably does not play a significant role in the loosening of endoprosthesis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信