南非约翰内斯堡学术流式细胞术实验室对固定面板多色ClearLLab 10C的评估。

IF 1 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
African Journal of Laboratory Medicine Pub Date : 2022-07-15 eCollection Date: 2022-01-01 DOI:10.4102/ajlm.v11i1.1458
Deborah K Glencross, Leanne Swart, Melanie Pretorius, Denise Lawrie
{"title":"南非约翰内斯堡学术流式细胞术实验室对固定面板多色ClearLLab 10C的评估。","authors":"Deborah K Glencross,&nbsp;Leanne Swart,&nbsp;Melanie Pretorius,&nbsp;Denise Lawrie","doi":"10.4102/ajlm.v11i1.1458","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Flow cytometric immunophenotyping is well established for the diagnosis of haematological neoplasms. New commercially available systems offer fixed, pre-aliquoted multi-parameter analysis to simplify sample preparation and standardise data analysis.</p><p><strong>Objective: </strong>The Beckman Coulter (BC) ClearLLab™ 10C (4-tube) system was evaluated against an existing laboratory developed test (LDT).</p><p><strong>Methods: </strong>Peripheral blood and bone marrow aspirates (<i>n</i> = 101), tested between August 2019 and November 2019 at an academic pathology laboratory in Johannesburg, South Africa, were analysed. Following daily instrument quality control, samples were prepared for LDT (using > 20 2-4-colour in-house panels and an extensive liquid monoclonal reagent repertoire) or ClearLLab 10C, and respectively analysed using in-house protocols on a Becton Dickinson FACSCalibur, or manufacturer-directed protocols on a BC Navios. Becton Dickinson Paint-a-Gate or BC Kaluza C software facilitated data interpretation. Diagnostic accuracy (concordance) was established by calculating sensitivity and specificity outcomes.</p><p><strong>Results: </strong>Excellent agreement (clinical diagnostic concordance) with 100% specificity and sensitivity was established between LDT and ClearLLab 10C in 67 patients with a haematological neoplasm and 34 participants with no haematological disease. Similar acceptable diagnostic concordance (97%) was noted when comparing ClearLLab 10C to clinicopathological outcomes. Additionally, the ClearLLab 10C panels, analysed with Kaluza C software, enabled simultaneous discrimination of disease and concurrent background myeloid and lymphoid haematological populations, including assessing stages of maturation or sub-populations.</p><p><strong>Conclusion: </strong>ClearLLab 10C panels provide excellent agreement to existing LDTs and may reliably be used for immunophenotyping of haematological neoplasms, simplifying and standardising sample preparation and data acquisition.</p>","PeriodicalId":45412,"journal":{"name":"African Journal of Laboratory Medicine","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2022-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9350555/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of fixed-panel, multicolour ClearLLab 10C at an academic flow cytometry laboratory in Johannesburg, South Africa.\",\"authors\":\"Deborah K Glencross,&nbsp;Leanne Swart,&nbsp;Melanie Pretorius,&nbsp;Denise Lawrie\",\"doi\":\"10.4102/ajlm.v11i1.1458\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Flow cytometric immunophenotyping is well established for the diagnosis of haematological neoplasms. New commercially available systems offer fixed, pre-aliquoted multi-parameter analysis to simplify sample preparation and standardise data analysis.</p><p><strong>Objective: </strong>The Beckman Coulter (BC) ClearLLab™ 10C (4-tube) system was evaluated against an existing laboratory developed test (LDT).</p><p><strong>Methods: </strong>Peripheral blood and bone marrow aspirates (<i>n</i> = 101), tested between August 2019 and November 2019 at an academic pathology laboratory in Johannesburg, South Africa, were analysed. Following daily instrument quality control, samples were prepared for LDT (using > 20 2-4-colour in-house panels and an extensive liquid monoclonal reagent repertoire) or ClearLLab 10C, and respectively analysed using in-house protocols on a Becton Dickinson FACSCalibur, or manufacturer-directed protocols on a BC Navios. Becton Dickinson Paint-a-Gate or BC Kaluza C software facilitated data interpretation. Diagnostic accuracy (concordance) was established by calculating sensitivity and specificity outcomes.</p><p><strong>Results: </strong>Excellent agreement (clinical diagnostic concordance) with 100% specificity and sensitivity was established between LDT and ClearLLab 10C in 67 patients with a haematological neoplasm and 34 participants with no haematological disease. Similar acceptable diagnostic concordance (97%) was noted when comparing ClearLLab 10C to clinicopathological outcomes. Additionally, the ClearLLab 10C panels, analysed with Kaluza C software, enabled simultaneous discrimination of disease and concurrent background myeloid and lymphoid haematological populations, including assessing stages of maturation or sub-populations.</p><p><strong>Conclusion: </strong>ClearLLab 10C panels provide excellent agreement to existing LDTs and may reliably be used for immunophenotyping of haematological neoplasms, simplifying and standardising sample preparation and data acquisition.</p>\",\"PeriodicalId\":45412,\"journal\":{\"name\":\"African Journal of Laboratory Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2022-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9350555/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"African Journal of Laboratory Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4102/ajlm.v11i1.1458\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4102/ajlm.v11i1.1458","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:流式细胞术免疫分型在血液学肿瘤的诊断中得到了很好的应用。新的商用系统提供固定的,预报价的多参数分析,以简化样品制备和标准化数据分析。目的:对Beckman Coulter (BC) ClearLLab™10C(4管)系统与现有实验室开发的测试(LDT)进行评估。方法:分析2019年8月至2019年11月在南非约翰内斯堡的一个学术病理实验室检测的外周血和骨髓抽吸物(n = 101)。在日常仪器质量控制之后,将样品准备用于LDT(使用> 20个2-4色内部面板和广泛的液体单克隆试剂库)或ClearLLab 10C,并分别使用内部协议在Becton Dickinson FACSCalibur上进行分析,或在BC Navios上使用制造商指导协议进行分析。Becton Dickinson Paint-a-Gate或BC Kaluza C软件有助于数据解释。通过计算敏感性和特异性结果来确定诊断准确性(一致性)。结果:在67例血液学肿瘤患者和34例无血液学疾病的参与者中,LDT和ClearLLab 10C之间建立了100%特异性和敏感性的极好一致性(临床诊断一致性)。在比较ClearLLab 10C与临床病理结果时,发现了类似的可接受的诊断一致性(97%)。此外,使用Kaluza C软件分析ClearLLab 10C面板,可以同时区分疾病和并发背景骨髓和淋巴血液学群体,包括评估成熟阶段或亚群体。结论:ClearLLab 10C面板与现有的ldt具有良好的一致性,可可靠地用于血液学肿瘤的免疫分型,简化和标准化样品制备和数据采集。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Evaluation of fixed-panel, multicolour ClearLLab 10C at an academic flow cytometry laboratory in Johannesburg, South Africa.

Evaluation of fixed-panel, multicolour ClearLLab 10C at an academic flow cytometry laboratory in Johannesburg, South Africa.

Evaluation of fixed-panel, multicolour ClearLLab 10C at an academic flow cytometry laboratory in Johannesburg, South Africa.

Evaluation of fixed-panel, multicolour ClearLLab 10C at an academic flow cytometry laboratory in Johannesburg, South Africa.

Background: Flow cytometric immunophenotyping is well established for the diagnosis of haematological neoplasms. New commercially available systems offer fixed, pre-aliquoted multi-parameter analysis to simplify sample preparation and standardise data analysis.

Objective: The Beckman Coulter (BC) ClearLLab™ 10C (4-tube) system was evaluated against an existing laboratory developed test (LDT).

Methods: Peripheral blood and bone marrow aspirates (n = 101), tested between August 2019 and November 2019 at an academic pathology laboratory in Johannesburg, South Africa, were analysed. Following daily instrument quality control, samples were prepared for LDT (using > 20 2-4-colour in-house panels and an extensive liquid monoclonal reagent repertoire) or ClearLLab 10C, and respectively analysed using in-house protocols on a Becton Dickinson FACSCalibur, or manufacturer-directed protocols on a BC Navios. Becton Dickinson Paint-a-Gate or BC Kaluza C software facilitated data interpretation. Diagnostic accuracy (concordance) was established by calculating sensitivity and specificity outcomes.

Results: Excellent agreement (clinical diagnostic concordance) with 100% specificity and sensitivity was established between LDT and ClearLLab 10C in 67 patients with a haematological neoplasm and 34 participants with no haematological disease. Similar acceptable diagnostic concordance (97%) was noted when comparing ClearLLab 10C to clinicopathological outcomes. Additionally, the ClearLLab 10C panels, analysed with Kaluza C software, enabled simultaneous discrimination of disease and concurrent background myeloid and lymphoid haematological populations, including assessing stages of maturation or sub-populations.

Conclusion: ClearLLab 10C panels provide excellent agreement to existing LDTs and may reliably be used for immunophenotyping of haematological neoplasms, simplifying and standardising sample preparation and data acquisition.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
African Journal of Laboratory Medicine
African Journal of Laboratory Medicine MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.70
自引率
9.10%
发文量
53
审稿时长
12 weeks
期刊介绍: The African Journal of Laboratory Medicine, the official journal of ASLM, focuses on the role of the laboratory and its professionals in the clinical and public healthcare sectors,and is specifically based on an African frame of reference. Emphasis is on all aspects that promote and contribute to the laboratory medicine practices of Africa. This includes, amongst others: laboratories, biomedical scientists and clinicians, medical community, public health officials and policy makers, laboratory systems and policies (translation of laboratory knowledge, practices and technologies in clinical care), interfaces of laboratory with medical science, laboratory-based epidemiology, laboratory investigations, evidence-based effectiveness in real world (actual) settings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信