{"title":"使用软性日用一次性镜片治疗散光超过16小时的佩戴体验评估。","authors":"Jennifer Swingle Fogt, Kimberly Patton","doi":"10.2147/OPTO.S387740","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The purpose of this study was to assess the wear experience of participants while wearing a toric daily disposable contact lens with water surface technology over long days of lens wear.</p><p><strong>Methods: </strong>Existing soft toric contact lens wearers were fit with the daily disposable study lenses. Participants assessed their initial comfort, vision, and satisfaction with the lenses by visual analog scale (VAS) survey. After a successful 1-week follow-up visit, participants were scheduled for 5 survey days, in which surveys were deployed to their smartphones for immediate assessments of comfort and quality of vision on a 1-10 scale at 10, 12, 14, and 16 hours of lens wear on 5 subsequent weeknights. The final study visit assessed visual acuity, and overall lens wear experience surveys were completed with VAS surveys. The overall median and interquartile (IQR) range of all surveys were calculated.</p><p><strong>Results: </strong>Thirty bilateral toric lens wearers completed the study. Median (IQR) initial impression VAS scores were 97(12) for quality of vision, 100(9) for comfort, and 96(10) for satisfaction. Median evening surveys resulted in comfort scores of 10(1) at 10 hours, 9(2) at 12 hours, 9(2) at 14 hours, and 8(2) at 16 hours of wear. Median evening surveys resulted in quality of vision scores of 10(1) at 10 hours, 10(2) at 12 hours, 9(2) at 14 hours, and 9(3) at 16 hours of wear. VAS scores for overall experience were 97(9) for comfort, 95(13) for vision, and 8(31) for dryness. End-of-day VAS scores were 93(21) for comfort, 90(15) for vision, and 21(38) for dryness. Mean (±standard deviation) OU LogMAR visual acuity with the study lenses was -0.19(0.06).</p><p><strong>Conclusion: </strong>Surveys of wear experience resulted in high scores for comfort and vision over the course of a long day of wear with the daily disposable study lenses in this population of patients with astigmatism.</p>","PeriodicalId":43701,"journal":{"name":"Clinical Optometry","volume":" ","pages":"207-214"},"PeriodicalIF":1.8000,"publicationDate":"2022-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/9d/cf/opto-14-207.PMC9624167.pdf","citationCount":"1","resultStr":"{\"title\":\"Evaluation of Wear Experience with Soft Daily Disposable Lenses for Astigmatism over 16 Hours of Wear.\",\"authors\":\"Jennifer Swingle Fogt, Kimberly Patton\",\"doi\":\"10.2147/OPTO.S387740\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The purpose of this study was to assess the wear experience of participants while wearing a toric daily disposable contact lens with water surface technology over long days of lens wear.</p><p><strong>Methods: </strong>Existing soft toric contact lens wearers were fit with the daily disposable study lenses. Participants assessed their initial comfort, vision, and satisfaction with the lenses by visual analog scale (VAS) survey. After a successful 1-week follow-up visit, participants were scheduled for 5 survey days, in which surveys were deployed to their smartphones for immediate assessments of comfort and quality of vision on a 1-10 scale at 10, 12, 14, and 16 hours of lens wear on 5 subsequent weeknights. The final study visit assessed visual acuity, and overall lens wear experience surveys were completed with VAS surveys. The overall median and interquartile (IQR) range of all surveys were calculated.</p><p><strong>Results: </strong>Thirty bilateral toric lens wearers completed the study. Median (IQR) initial impression VAS scores were 97(12) for quality of vision, 100(9) for comfort, and 96(10) for satisfaction. Median evening surveys resulted in comfort scores of 10(1) at 10 hours, 9(2) at 12 hours, 9(2) at 14 hours, and 8(2) at 16 hours of wear. Median evening surveys resulted in quality of vision scores of 10(1) at 10 hours, 10(2) at 12 hours, 9(2) at 14 hours, and 9(3) at 16 hours of wear. VAS scores for overall experience were 97(9) for comfort, 95(13) for vision, and 8(31) for dryness. End-of-day VAS scores were 93(21) for comfort, 90(15) for vision, and 21(38) for dryness. Mean (±standard deviation) OU LogMAR visual acuity with the study lenses was -0.19(0.06).</p><p><strong>Conclusion: </strong>Surveys of wear experience resulted in high scores for comfort and vision over the course of a long day of wear with the daily disposable study lenses in this population of patients with astigmatism.</p>\",\"PeriodicalId\":43701,\"journal\":{\"name\":\"Clinical Optometry\",\"volume\":\" \",\"pages\":\"207-214\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2022-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/9d/cf/opto-14-207.PMC9624167.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Optometry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/OPTO.S387740\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Optometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTO.S387740","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Evaluation of Wear Experience with Soft Daily Disposable Lenses for Astigmatism over 16 Hours of Wear.
Objective: The purpose of this study was to assess the wear experience of participants while wearing a toric daily disposable contact lens with water surface technology over long days of lens wear.
Methods: Existing soft toric contact lens wearers were fit with the daily disposable study lenses. Participants assessed their initial comfort, vision, and satisfaction with the lenses by visual analog scale (VAS) survey. After a successful 1-week follow-up visit, participants were scheduled for 5 survey days, in which surveys were deployed to their smartphones for immediate assessments of comfort and quality of vision on a 1-10 scale at 10, 12, 14, and 16 hours of lens wear on 5 subsequent weeknights. The final study visit assessed visual acuity, and overall lens wear experience surveys were completed with VAS surveys. The overall median and interquartile (IQR) range of all surveys were calculated.
Results: Thirty bilateral toric lens wearers completed the study. Median (IQR) initial impression VAS scores were 97(12) for quality of vision, 100(9) for comfort, and 96(10) for satisfaction. Median evening surveys resulted in comfort scores of 10(1) at 10 hours, 9(2) at 12 hours, 9(2) at 14 hours, and 8(2) at 16 hours of wear. Median evening surveys resulted in quality of vision scores of 10(1) at 10 hours, 10(2) at 12 hours, 9(2) at 14 hours, and 9(3) at 16 hours of wear. VAS scores for overall experience were 97(9) for comfort, 95(13) for vision, and 8(31) for dryness. End-of-day VAS scores were 93(21) for comfort, 90(15) for vision, and 21(38) for dryness. Mean (±standard deviation) OU LogMAR visual acuity with the study lenses was -0.19(0.06).
Conclusion: Surveys of wear experience resulted in high scores for comfort and vision over the course of a long day of wear with the daily disposable study lenses in this population of patients with astigmatism.
期刊介绍:
Clinical Optometry is an international, peer-reviewed, open access journal focusing on clinical optometry. All aspects of patient care are addressed within the journal as well as the practice of optometry including economic and business analyses. Basic and clinical research papers are published that cover all aspects of optics, refraction and its application to the theory and practice of optometry. Specific topics covered in the journal include: Theoretical and applied optics, Delivery of patient care in optometry practice, Refraction and correction of errors, Screening and preventative aspects of eye disease, Extended clinical roles for optometrists including shared care and provision of medications, Teaching and training optometrists, International aspects of optometry, Business practice, Patient adherence, quality of life, satisfaction, Health economic evaluations.