优化相关的超分辨率和原子力显微镜用于研究细胞骨架。

IF 2.4 3区 化学 Q3 CHEMISTRY, ANALYTICAL
Riley B Hargreaves, Ashley M Rozario, Thomas M McCoy, Shane P Meaney, Alison M Funston, Rico F Tabor, Donna R Whelan, Toby D M Bell
{"title":"优化相关的超分辨率和原子力显微镜用于研究细胞骨架。","authors":"Riley B Hargreaves,&nbsp;Ashley M Rozario,&nbsp;Thomas M McCoy,&nbsp;Shane P Meaney,&nbsp;Alison M Funston,&nbsp;Rico F Tabor,&nbsp;Donna R Whelan,&nbsp;Toby D M Bell","doi":"10.1088/2050-6120/ac8526","DOIUrl":null,"url":null,"abstract":"<p><p>Correlative imaging methods can provide greater information for investigations of cellular ultra-structure, with separate analysis methods complementing each other's strengths and covering for deficiencies. Here we present a method for correlative applications of super resolution and atomic force microscopies, optimising the sample preparation for correlative imaging of the cellular cytoskeleton in COS-7 cells. This optimisation determined the order of permeabilisation and fixation, the concentration of Triton X-100 surfactant used and time required for sufficient removal of the cellular membrane while maintaining the microtubule network. Correlative SMLM/AFM imaging revealed the different information that can be obtained through each microscopy. The widths of microtubules and microtubule clusters were determined from both AFM height measurements and Gaussian fitting of SMLM intensity cross sections, these were then compared to determine the orientation of microtubules within larger microtubule bundles. The ordering of microtubules at intersections was determined from the AFM height profiles as each microtubule crosses the other. The combination of both microtubule diameter measurements enabled greater information on their structure to be found than either measurement could individually.</p>","PeriodicalId":18596,"journal":{"name":"Methods and Applications in Fluorescence","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2022-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Optimising correlative super resolution and atomic force microscopies for investigating the cellular cytoskeleton.\",\"authors\":\"Riley B Hargreaves,&nbsp;Ashley M Rozario,&nbsp;Thomas M McCoy,&nbsp;Shane P Meaney,&nbsp;Alison M Funston,&nbsp;Rico F Tabor,&nbsp;Donna R Whelan,&nbsp;Toby D M Bell\",\"doi\":\"10.1088/2050-6120/ac8526\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Correlative imaging methods can provide greater information for investigations of cellular ultra-structure, with separate analysis methods complementing each other's strengths and covering for deficiencies. Here we present a method for correlative applications of super resolution and atomic force microscopies, optimising the sample preparation for correlative imaging of the cellular cytoskeleton in COS-7 cells. This optimisation determined the order of permeabilisation and fixation, the concentration of Triton X-100 surfactant used and time required for sufficient removal of the cellular membrane while maintaining the microtubule network. Correlative SMLM/AFM imaging revealed the different information that can be obtained through each microscopy. The widths of microtubules and microtubule clusters were determined from both AFM height measurements and Gaussian fitting of SMLM intensity cross sections, these were then compared to determine the orientation of microtubules within larger microtubule bundles. The ordering of microtubules at intersections was determined from the AFM height profiles as each microtubule crosses the other. The combination of both microtubule diameter measurements enabled greater information on their structure to be found than either measurement could individually.</p>\",\"PeriodicalId\":18596,\"journal\":{\"name\":\"Methods and Applications in Fluorescence\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2022-08-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Methods and Applications in Fluorescence\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1088/2050-6120/ac8526\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Methods and Applications in Fluorescence","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1088/2050-6120/ac8526","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 1

摘要

相关的成像方法可以为细胞超微结构的研究提供更多的信息,不同的分析方法可以互补,弥补不足。本文提出了一种超分辨率和原子力显微镜相关应用的方法,优化了COS-7细胞骨架相关成像的样品制备方法。这种优化决定了渗透和固定的顺序、使用的Triton X-100表面活性剂的浓度以及在保持微管网络的同时充分去除细胞膜所需的时间。相关的SMLM/AFM成像显示了通过每种显微镜可以获得的不同信息。通过AFM高度测量和SMLM强度截面的高斯拟合确定微管和微管簇的宽度,然后将这些数据进行比较,以确定较大微管束内微管的方向。当每个微管穿过另一个微管时,从AFM高度剖面确定交叉处微管的顺序。两种微管直径测量的结合比单独测量可以发现更多的结构信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimising correlative super resolution and atomic force microscopies for investigating the cellular cytoskeleton.

Correlative imaging methods can provide greater information for investigations of cellular ultra-structure, with separate analysis methods complementing each other's strengths and covering for deficiencies. Here we present a method for correlative applications of super resolution and atomic force microscopies, optimising the sample preparation for correlative imaging of the cellular cytoskeleton in COS-7 cells. This optimisation determined the order of permeabilisation and fixation, the concentration of Triton X-100 surfactant used and time required for sufficient removal of the cellular membrane while maintaining the microtubule network. Correlative SMLM/AFM imaging revealed the different information that can be obtained through each microscopy. The widths of microtubules and microtubule clusters were determined from both AFM height measurements and Gaussian fitting of SMLM intensity cross sections, these were then compared to determine the orientation of microtubules within larger microtubule bundles. The ordering of microtubules at intersections was determined from the AFM height profiles as each microtubule crosses the other. The combination of both microtubule diameter measurements enabled greater information on their structure to be found than either measurement could individually.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Methods and Applications in Fluorescence
Methods and Applications in Fluorescence CHEMISTRY, ANALYTICALCHEMISTRY, PHYSICAL&n-CHEMISTRY, PHYSICAL
CiteScore
6.20
自引率
3.10%
发文量
60
期刊介绍: Methods and Applications in Fluorescence focuses on new developments in fluorescence spectroscopy, imaging, microscopy, fluorescent probes, labels and (nano)materials. It will feature both methods and advanced (bio)applications and accepts original research articles, reviews and technical notes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信