Kafui C Kouassi, Améyo M Dorkenoo, Komivi Gbada, Yaovi-Gameli Afanyibo, Minogblon Têko, Adjane Koura
{"title":"多哥国家基本临床化学测试能力测试试点方案。","authors":"Kafui C Kouassi, Améyo M Dorkenoo, Komivi Gbada, Yaovi-Gameli Afanyibo, Minogblon Têko, Adjane Koura","doi":"10.4102/ajlm.v11i1.1565","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>A national proficiency test (PT) programme is not currently implemented in most low-income countries. However, participation in such PT programmes assists improves test performance and result accuracy.</p><p><strong>Objective: </strong>This study assessed how well 11 government hospital laboratories performed 18 basic clinical chemistry tests and identified areas needing improvement.</p><p><strong>Methods: </strong>A cross-sectional study was carried out by the Division of Laboratories of the Ministry of Health of Togo from 01 July 2016 to 31 December 2016. The test performance was evaluated using panels provided by One World Accuracy, Canada (Vancouver). The Clinical Laboratory Improvement Amendments criteria were used in evaluating the laboratories, and their success rates were compared with the World Health Organization Regional Office for Africa's target of 80%.</p><p><strong>Results: </strong>The overall rate of acceptable results at the laboratories was over 80% for glucose, alanine aminotransferase, aspartate aminotransferase, gamma-glutamyltransferase, alkaline phosphatase and triglycerides tests. The laboratories using fully automated spectrophotometers had an acceptable results rate of 89% (<i>p</i> = 0.001). The overall performance of the laboratories by cycles varied from 71% to 82%.</p><p><strong>Conclusion: </strong>This national PT programme identified the tests, which laboratories must improve their performance (urea, creatinine, uric acid, bilirubin, cholesterol, total protein, calcium, magnesium, phosphorus). It demonstrated the need for the use of routine appropriate internal quality control in all laboratories. The proficiency test programme should be extended to all clinical laboratories and target all biology disciplines.</p>","PeriodicalId":45412,"journal":{"name":"African Journal of Laboratory Medicine","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2022-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9257935/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Togo national proficiency test pilot programme for basic clinical chemistry tests.\",\"authors\":\"Kafui C Kouassi, Améyo M Dorkenoo, Komivi Gbada, Yaovi-Gameli Afanyibo, Minogblon Têko, Adjane Koura\",\"doi\":\"10.4102/ajlm.v11i1.1565\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>A national proficiency test (PT) programme is not currently implemented in most low-income countries. However, participation in such PT programmes assists improves test performance and result accuracy.</p><p><strong>Objective: </strong>This study assessed how well 11 government hospital laboratories performed 18 basic clinical chemistry tests and identified areas needing improvement.</p><p><strong>Methods: </strong>A cross-sectional study was carried out by the Division of Laboratories of the Ministry of Health of Togo from 01 July 2016 to 31 December 2016. The test performance was evaluated using panels provided by One World Accuracy, Canada (Vancouver). The Clinical Laboratory Improvement Amendments criteria were used in evaluating the laboratories, and their success rates were compared with the World Health Organization Regional Office for Africa's target of 80%.</p><p><strong>Results: </strong>The overall rate of acceptable results at the laboratories was over 80% for glucose, alanine aminotransferase, aspartate aminotransferase, gamma-glutamyltransferase, alkaline phosphatase and triglycerides tests. The laboratories using fully automated spectrophotometers had an acceptable results rate of 89% (<i>p</i> = 0.001). The overall performance of the laboratories by cycles varied from 71% to 82%.</p><p><strong>Conclusion: </strong>This national PT programme identified the tests, which laboratories must improve their performance (urea, creatinine, uric acid, bilirubin, cholesterol, total protein, calcium, magnesium, phosphorus). It demonstrated the need for the use of routine appropriate internal quality control in all laboratories. The proficiency test programme should be extended to all clinical laboratories and target all biology disciplines.</p>\",\"PeriodicalId\":45412,\"journal\":{\"name\":\"African Journal of Laboratory Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2022-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9257935/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"African Journal of Laboratory Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4102/ajlm.v11i1.1565\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4102/ajlm.v11i1.1565","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
The Togo national proficiency test pilot programme for basic clinical chemistry tests.
Background: A national proficiency test (PT) programme is not currently implemented in most low-income countries. However, participation in such PT programmes assists improves test performance and result accuracy.
Objective: This study assessed how well 11 government hospital laboratories performed 18 basic clinical chemistry tests and identified areas needing improvement.
Methods: A cross-sectional study was carried out by the Division of Laboratories of the Ministry of Health of Togo from 01 July 2016 to 31 December 2016. The test performance was evaluated using panels provided by One World Accuracy, Canada (Vancouver). The Clinical Laboratory Improvement Amendments criteria were used in evaluating the laboratories, and their success rates were compared with the World Health Organization Regional Office for Africa's target of 80%.
Results: The overall rate of acceptable results at the laboratories was over 80% for glucose, alanine aminotransferase, aspartate aminotransferase, gamma-glutamyltransferase, alkaline phosphatase and triglycerides tests. The laboratories using fully automated spectrophotometers had an acceptable results rate of 89% (p = 0.001). The overall performance of the laboratories by cycles varied from 71% to 82%.
Conclusion: This national PT programme identified the tests, which laboratories must improve their performance (urea, creatinine, uric acid, bilirubin, cholesterol, total protein, calcium, magnesium, phosphorus). It demonstrated the need for the use of routine appropriate internal quality control in all laboratories. The proficiency test programme should be extended to all clinical laboratories and target all biology disciplines.
期刊介绍:
The African Journal of Laboratory Medicine, the official journal of ASLM, focuses on the role of the laboratory and its professionals in the clinical and public healthcare sectors,and is specifically based on an African frame of reference. Emphasis is on all aspects that promote and contribute to the laboratory medicine practices of Africa. This includes, amongst others: laboratories, biomedical scientists and clinicians, medical community, public health officials and policy makers, laboratory systems and policies (translation of laboratory knowledge, practices and technologies in clinical care), interfaces of laboratory with medical science, laboratory-based epidemiology, laboratory investigations, evidence-based effectiveness in real world (actual) settings.