人体测量可以用来指示参与者特定的大腿标记物的位置,从而最小化髋关节中心估计的误差吗?

IF 1.1 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Journal of Applied Biomechanics Pub Date : 2022-07-13 Print Date: 2022-08-01 DOI:10.1123/jab.2022-0042
Jessa M Buchman-Pearle, Stacey M Acker
{"title":"人体测量可以用来指示参与者特定的大腿标记物的位置,从而最小化髋关节中心估计的误差吗?","authors":"Jessa M Buchman-Pearle,&nbsp;Stacey M Acker","doi":"10.1123/jab.2022-0042","DOIUrl":null,"url":null,"abstract":"<p><p>Specific participant characteristics may be leveraged to dictate marker placements which reduce soft tissue artifact; however, a better understanding of the relationships between participant characteristics and soft tissue artifact are first required. The purpose of this study was to assess the accuracy in which measures of whole-body and thigh anthropometry could predict mislocation error of the hip joint center, tracked using skin-mounted marker clusters. Fifty participants completed squatting and kneeling, while pelvis and lower limb motion were recorded. The effect of soft tissue artifact was estimated from 6 rigid thigh marker clusters by evaluating their ability to track the position of the hip joint center most like the pelvis cluster. Eighteen backward stepwise linear regressions were performed using 10 anthropometric measures as independent variables and the mean of the peak difference between the thigh and pelvis cluster-tracked hip joint centers. Fourteen models significantly predicted error with low to moderate fit (R = .38-.67), explaining 14% to 45% of variation. Partial correlations indicated that soft tissue artifact may increase with soft tissue volume and be altered by local soft tissue composition. However, it is not recommended that marker placement be adjusted based on anthropometry alone.</p>","PeriodicalId":54883,"journal":{"name":"Journal of Applied Biomechanics","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2022-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Can Anthropometry be Used to Dictate Participant-Specific Thigh Marker Placements Which Minimize Error in Hip Joint Center Estimation?\",\"authors\":\"Jessa M Buchman-Pearle,&nbsp;Stacey M Acker\",\"doi\":\"10.1123/jab.2022-0042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Specific participant characteristics may be leveraged to dictate marker placements which reduce soft tissue artifact; however, a better understanding of the relationships between participant characteristics and soft tissue artifact are first required. The purpose of this study was to assess the accuracy in which measures of whole-body and thigh anthropometry could predict mislocation error of the hip joint center, tracked using skin-mounted marker clusters. Fifty participants completed squatting and kneeling, while pelvis and lower limb motion were recorded. The effect of soft tissue artifact was estimated from 6 rigid thigh marker clusters by evaluating their ability to track the position of the hip joint center most like the pelvis cluster. Eighteen backward stepwise linear regressions were performed using 10 anthropometric measures as independent variables and the mean of the peak difference between the thigh and pelvis cluster-tracked hip joint centers. Fourteen models significantly predicted error with low to moderate fit (R = .38-.67), explaining 14% to 45% of variation. Partial correlations indicated that soft tissue artifact may increase with soft tissue volume and be altered by local soft tissue composition. However, it is not recommended that marker placement be adjusted based on anthropometry alone.</p>\",\"PeriodicalId\":54883,\"journal\":{\"name\":\"Journal of Applied Biomechanics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2022-07-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Biomechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1123/jab.2022-0042\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/8/1 0:00:00\",\"PubModel\":\"Print\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1123/jab.2022-0042","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/1 0:00:00","PubModel":"Print","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

可以利用特定的参与者特征来指示减少软组织伪影的标记位置;然而,首先需要更好地理解参与者特征与软组织伪影之间的关系。本研究的目的是评估全身和大腿人体测量测量的准确性,利用皮肤上的标记簇进行跟踪,预测髋关节中心的错位误差。50名参与者完成了下蹲和跪,同时记录了骨盆和下肢的运动。软组织伪影的影响是通过评估6个刚性大腿标记簇跟踪髋关节中心位置的能力来估计的,最像骨盆簇。采用10项人体测量指标作为自变量和大腿和骨盆之间的峰值差均值进行18次逐步回归。14个模型显著预测了低至中等拟合误差(R = 0.38 - 0.67),解释了14%至45%的变异。部分相关表明,软组织伪影可能随着软组织体积的增加而增加,并受局部软组织组成的改变。然而,不建议仅根据人体测量来调整标记物的位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Can Anthropometry be Used to Dictate Participant-Specific Thigh Marker Placements Which Minimize Error in Hip Joint Center Estimation?

Specific participant characteristics may be leveraged to dictate marker placements which reduce soft tissue artifact; however, a better understanding of the relationships between participant characteristics and soft tissue artifact are first required. The purpose of this study was to assess the accuracy in which measures of whole-body and thigh anthropometry could predict mislocation error of the hip joint center, tracked using skin-mounted marker clusters. Fifty participants completed squatting and kneeling, while pelvis and lower limb motion were recorded. The effect of soft tissue artifact was estimated from 6 rigid thigh marker clusters by evaluating their ability to track the position of the hip joint center most like the pelvis cluster. Eighteen backward stepwise linear regressions were performed using 10 anthropometric measures as independent variables and the mean of the peak difference between the thigh and pelvis cluster-tracked hip joint centers. Fourteen models significantly predicted error with low to moderate fit (R = .38-.67), explaining 14% to 45% of variation. Partial correlations indicated that soft tissue artifact may increase with soft tissue volume and be altered by local soft tissue composition. However, it is not recommended that marker placement be adjusted based on anthropometry alone.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Applied Biomechanics
Journal of Applied Biomechanics 医学-工程:生物医学
CiteScore
2.00
自引率
0.00%
发文量
47
审稿时长
6-12 weeks
期刊介绍: The mission of the Journal of Applied Biomechanics (JAB) is to disseminate the highest quality peer-reviewed studies that utilize biomechanical strategies to advance the study of human movement. Areas of interest include clinical biomechanics, gait and posture mechanics, musculoskeletal and neuromuscular biomechanics, sport mechanics, and biomechanical modeling. Studies of sport performance that explicitly generalize to broader activities, contribute substantially to fundamental understanding of human motion, or are in a sport that enjoys wide participation, are welcome. Also within the scope of JAB are studies using biomechanical strategies to investigate the structure, control, function, and state (health and disease) of animals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信