{"title":"人体测量可以用来指示参与者特定的大腿标记物的位置,从而最小化髋关节中心估计的误差吗?","authors":"Jessa M Buchman-Pearle, Stacey M Acker","doi":"10.1123/jab.2022-0042","DOIUrl":null,"url":null,"abstract":"<p><p>Specific participant characteristics may be leveraged to dictate marker placements which reduce soft tissue artifact; however, a better understanding of the relationships between participant characteristics and soft tissue artifact are first required. The purpose of this study was to assess the accuracy in which measures of whole-body and thigh anthropometry could predict mislocation error of the hip joint center, tracked using skin-mounted marker clusters. Fifty participants completed squatting and kneeling, while pelvis and lower limb motion were recorded. The effect of soft tissue artifact was estimated from 6 rigid thigh marker clusters by evaluating their ability to track the position of the hip joint center most like the pelvis cluster. Eighteen backward stepwise linear regressions were performed using 10 anthropometric measures as independent variables and the mean of the peak difference between the thigh and pelvis cluster-tracked hip joint centers. Fourteen models significantly predicted error with low to moderate fit (R = .38-.67), explaining 14% to 45% of variation. Partial correlations indicated that soft tissue artifact may increase with soft tissue volume and be altered by local soft tissue composition. However, it is not recommended that marker placement be adjusted based on anthropometry alone.</p>","PeriodicalId":54883,"journal":{"name":"Journal of Applied Biomechanics","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2022-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Can Anthropometry be Used to Dictate Participant-Specific Thigh Marker Placements Which Minimize Error in Hip Joint Center Estimation?\",\"authors\":\"Jessa M Buchman-Pearle, Stacey M Acker\",\"doi\":\"10.1123/jab.2022-0042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Specific participant characteristics may be leveraged to dictate marker placements which reduce soft tissue artifact; however, a better understanding of the relationships between participant characteristics and soft tissue artifact are first required. The purpose of this study was to assess the accuracy in which measures of whole-body and thigh anthropometry could predict mislocation error of the hip joint center, tracked using skin-mounted marker clusters. Fifty participants completed squatting and kneeling, while pelvis and lower limb motion were recorded. The effect of soft tissue artifact was estimated from 6 rigid thigh marker clusters by evaluating their ability to track the position of the hip joint center most like the pelvis cluster. Eighteen backward stepwise linear regressions were performed using 10 anthropometric measures as independent variables and the mean of the peak difference between the thigh and pelvis cluster-tracked hip joint centers. Fourteen models significantly predicted error with low to moderate fit (R = .38-.67), explaining 14% to 45% of variation. Partial correlations indicated that soft tissue artifact may increase with soft tissue volume and be altered by local soft tissue composition. However, it is not recommended that marker placement be adjusted based on anthropometry alone.</p>\",\"PeriodicalId\":54883,\"journal\":{\"name\":\"Journal of Applied Biomechanics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2022-07-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Biomechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1123/jab.2022-0042\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/8/1 0:00:00\",\"PubModel\":\"Print\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1123/jab.2022-0042","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/1 0:00:00","PubModel":"Print","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Can Anthropometry be Used to Dictate Participant-Specific Thigh Marker Placements Which Minimize Error in Hip Joint Center Estimation?
Specific participant characteristics may be leveraged to dictate marker placements which reduce soft tissue artifact; however, a better understanding of the relationships between participant characteristics and soft tissue artifact are first required. The purpose of this study was to assess the accuracy in which measures of whole-body and thigh anthropometry could predict mislocation error of the hip joint center, tracked using skin-mounted marker clusters. Fifty participants completed squatting and kneeling, while pelvis and lower limb motion were recorded. The effect of soft tissue artifact was estimated from 6 rigid thigh marker clusters by evaluating their ability to track the position of the hip joint center most like the pelvis cluster. Eighteen backward stepwise linear regressions were performed using 10 anthropometric measures as independent variables and the mean of the peak difference between the thigh and pelvis cluster-tracked hip joint centers. Fourteen models significantly predicted error with low to moderate fit (R = .38-.67), explaining 14% to 45% of variation. Partial correlations indicated that soft tissue artifact may increase with soft tissue volume and be altered by local soft tissue composition. However, it is not recommended that marker placement be adjusted based on anthropometry alone.
期刊介绍:
The mission of the Journal of Applied Biomechanics (JAB) is to disseminate the highest quality peer-reviewed studies that utilize biomechanical strategies to advance the study of human movement. Areas of interest include clinical biomechanics, gait and posture mechanics, musculoskeletal and neuromuscular biomechanics, sport mechanics, and biomechanical modeling. Studies of sport performance that explicitly generalize to broader activities, contribute substantially to fundamental understanding of human motion, or are in a sport that enjoys wide participation, are welcome. Also within the scope of JAB are studies using biomechanical strategies to investigate the structure, control, function, and state (health and disease) of animals.