Halo-V组合线圈经颅磁刺激脑组织感应场分析。

IF 1.7 Q4 NEUROSCIENCES
Neurology Research International Pub Date : 2022-07-14 eCollection Date: 2022-01-01 DOI:10.1155/2022/7424564
Khaleda Akhter Sathi, Md Kamal Hosain, Md Azad Hossain
{"title":"Halo-V组合线圈经颅磁刺激脑组织感应场分析。","authors":"Khaleda Akhter Sathi,&nbsp;Md Kamal Hosain,&nbsp;Md Azad Hossain","doi":"10.1155/2022/7424564","DOIUrl":null,"url":null,"abstract":"<p><p>As a noninvasive neuromodulation technique, transcranial magnetic stimulation (TMS) has already exhibited a great impact in clinical application and scientific research. This study presents a finite element method-based simulation of the Halo-V assembly (HVA) coil placed on the five-shell spherical human head model to examine the distributions of induced electric and magnetic fields. The performance of the designed HVA coil is evaluated by comparing the simulation results with the commercially available Halo-FO8 (HFA) assembly coil and standard single coils including the Halo and V coils. The simulation results indicate that the HVA coil shows an improved focality in terms of electric field distribution than the other single and assembly stimulation coils. Additionally, the effects of a magnetic shield plate and magnetic core on the designed HVA coil are investigated. Results indicate that the magnetic shield plate and magnetic core are proficient in further improving the stimulation focality. Therefore, the HVA TMS coil results in a safe and effective stimulation with enhanced focality of the target region as compared to the existing assembly coil.</p>","PeriodicalId":19124,"journal":{"name":"Neurology Research International","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2022-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9303497/pdf/","citationCount":"3","resultStr":"{\"title\":\"Analysis of Induced Field in the Brain Tissue by Transcranial Magnetic Stimulation Using Halo-V Assembly Coil.\",\"authors\":\"Khaleda Akhter Sathi,&nbsp;Md Kamal Hosain,&nbsp;Md Azad Hossain\",\"doi\":\"10.1155/2022/7424564\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>As a noninvasive neuromodulation technique, transcranial magnetic stimulation (TMS) has already exhibited a great impact in clinical application and scientific research. This study presents a finite element method-based simulation of the Halo-V assembly (HVA) coil placed on the five-shell spherical human head model to examine the distributions of induced electric and magnetic fields. The performance of the designed HVA coil is evaluated by comparing the simulation results with the commercially available Halo-FO8 (HFA) assembly coil and standard single coils including the Halo and V coils. The simulation results indicate that the HVA coil shows an improved focality in terms of electric field distribution than the other single and assembly stimulation coils. Additionally, the effects of a magnetic shield plate and magnetic core on the designed HVA coil are investigated. Results indicate that the magnetic shield plate and magnetic core are proficient in further improving the stimulation focality. Therefore, the HVA TMS coil results in a safe and effective stimulation with enhanced focality of the target region as compared to the existing assembly coil.</p>\",\"PeriodicalId\":19124,\"journal\":{\"name\":\"Neurology Research International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2022-07-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9303497/pdf/\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Neurology Research International\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2022/7424564\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurology Research International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2022/7424564","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 3

摘要

经颅磁刺激(transcranial magnetic stimulation, TMS)作为一种无创神经调节技术,已经在临床应用和科学研究中显示出巨大的影响。本文提出了一种基于有限元法的仿真方法,将Halo-V组件(HVA)线圈放置在五壳球形人体头部模型上,以研究感应电场和磁场的分布。通过将仿真结果与市售的Halo- fo8 (HFA)组件线圈和包括Halo和V线圈在内的标准单线圈进行比较,对所设计的HVA线圈的性能进行了评估。仿真结果表明,高压伏安线圈在电场分布上的聚焦性优于其他单线圈和组合线圈。此外,还研究了磁屏蔽板和磁芯对设计的高压高压线圈的影响。结果表明,磁屏蔽板和磁芯能够有效地进一步提高刺激的聚焦性。因此,与现有的装配线圈相比,HVA TMS线圈可以实现安全有效的刺激,并增强了目标区域的聚焦。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Analysis of Induced Field in the Brain Tissue by Transcranial Magnetic Stimulation Using Halo-V Assembly Coil.

Analysis of Induced Field in the Brain Tissue by Transcranial Magnetic Stimulation Using Halo-V Assembly Coil.

Analysis of Induced Field in the Brain Tissue by Transcranial Magnetic Stimulation Using Halo-V Assembly Coil.

Analysis of Induced Field in the Brain Tissue by Transcranial Magnetic Stimulation Using Halo-V Assembly Coil.

As a noninvasive neuromodulation technique, transcranial magnetic stimulation (TMS) has already exhibited a great impact in clinical application and scientific research. This study presents a finite element method-based simulation of the Halo-V assembly (HVA) coil placed on the five-shell spherical human head model to examine the distributions of induced electric and magnetic fields. The performance of the designed HVA coil is evaluated by comparing the simulation results with the commercially available Halo-FO8 (HFA) assembly coil and standard single coils including the Halo and V coils. The simulation results indicate that the HVA coil shows an improved focality in terms of electric field distribution than the other single and assembly stimulation coils. Additionally, the effects of a magnetic shield plate and magnetic core on the designed HVA coil are investigated. Results indicate that the magnetic shield plate and magnetic core are proficient in further improving the stimulation focality. Therefore, the HVA TMS coil results in a safe and effective stimulation with enhanced focality of the target region as compared to the existing assembly coil.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
0.00%
发文量
10
审稿时长
17 weeks
期刊介绍: Neurology Research International is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies focusing on diseases of the nervous system, as well as normal neurological functioning. The journal will consider basic, translational, and clinical research, including animal models and clinical trials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信