Maciej Grymuza, Agnieszka Katarzyńska-Szymańska, Lidia Chmielewska-Michalak, Michał Waśniewski, Romuald Ochotny, Maciej Lesiak, Przemysław Mitkowski
{"title":"心脏再同步治疗植入并发症:全新植入与升级换代。","authors":"Maciej Grymuza, Agnieszka Katarzyńska-Szymańska, Lidia Chmielewska-Michalak, Michał Waśniewski, Romuald Ochotny, Maciej Lesiak, Przemysław Mitkowski","doi":"10.5603/CJ.a2022.0057","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cardiac resynchronization therapy (CRT) is a well-established treatment of patients with advanced heart failure and electrical dyssynchrony. Implantation of those devices is in some cases associated with intervention on a formerly implanted system. The aim of this analysis was to compare the rate and type of complications of de novo implants and upgrades to CRT-D.</p><p><strong>Methods: </strong>Retrospective data were collected from medical records, including 326 patients treated with CRT-D between 2015 and 2020. The following data were analyzed: procedure data including complications, demographics, co-morbidities, pharmacotherapy, and laboratory tests. The primary endpoint of the study was all-cause mortality.</p><p><strong>Results: </strong>A total of 326 procedure were included, of which 53% (n = 172) were de novo implants and 47% (n = 154) were upgrades. The groups did not differ in the incidence of complications: in the de novo group: 25.5% (n = 44); in the upgrade group: 30.5% (n = 47), p = 0.78. The incidence of complications was also similar in respect of the following: early (p = 0.98) and late (p = 0.45), infectious (p = 0.38) and non-infectious (p = 0.82), surgical (p = 0.38) and device or lead related (p = 0.6). The most common complication in the upgrade group was pocket hematoma (n = 9, 5.8%) and in the de novo group pneumothorax (n = 8, 4.7%).</p><p><strong>Conclusions: </strong>Upgrade procedures of are not associated with a higher percentage of complications than de novo implantations of CRT-D. Previously implanted cardiac implantable electronic device should not limit the implantation of CRT-Ds.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":" ","pages":"621-627"},"PeriodicalIF":4.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11374333/pdf/","citationCount":"0","resultStr":"{\"title\":\"Complications of cardiac resynchronization therapy implantation: De novo implants versus upgrades.\",\"authors\":\"Maciej Grymuza, Agnieszka Katarzyńska-Szymańska, Lidia Chmielewska-Michalak, Michał Waśniewski, Romuald Ochotny, Maciej Lesiak, Przemysław Mitkowski\",\"doi\":\"10.5603/CJ.a2022.0057\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Cardiac resynchronization therapy (CRT) is a well-established treatment of patients with advanced heart failure and electrical dyssynchrony. Implantation of those devices is in some cases associated with intervention on a formerly implanted system. The aim of this analysis was to compare the rate and type of complications of de novo implants and upgrades to CRT-D.</p><p><strong>Methods: </strong>Retrospective data were collected from medical records, including 326 patients treated with CRT-D between 2015 and 2020. The following data were analyzed: procedure data including complications, demographics, co-morbidities, pharmacotherapy, and laboratory tests. The primary endpoint of the study was all-cause mortality.</p><p><strong>Results: </strong>A total of 326 procedure were included, of which 53% (n = 172) were de novo implants and 47% (n = 154) were upgrades. The groups did not differ in the incidence of complications: in the de novo group: 25.5% (n = 44); in the upgrade group: 30.5% (n = 47), p = 0.78. The incidence of complications was also similar in respect of the following: early (p = 0.98) and late (p = 0.45), infectious (p = 0.38) and non-infectious (p = 0.82), surgical (p = 0.38) and device or lead related (p = 0.6). The most common complication in the upgrade group was pocket hematoma (n = 9, 5.8%) and in the de novo group pneumothorax (n = 8, 4.7%).</p><p><strong>Conclusions: </strong>Upgrade procedures of are not associated with a higher percentage of complications than de novo implantations of CRT-D. Previously implanted cardiac implantable electronic device should not limit the implantation of CRT-Ds.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":\" \",\"pages\":\"621-627\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11374333/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5603/CJ.a2022.0057\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/6/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5603/CJ.a2022.0057","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/6/28 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

背景:心脏再同步化疗法(CRT)是治疗晚期心力衰竭和心电不同步患者的一种行之有效的方法。在某些情况下,植入这些设备与对以前植入的系统进行干预有关。本分析旨在比较重新植入和升级为 CRT-D 的并发症发生率和类型:从医疗记录中收集了回顾性数据,其中包括 2015 年至 2020 年间接受 CRT-D 治疗的 326 名患者。分析了以下数据:包括并发症在内的手术数据、人口统计学、并发症、药物治疗和实验室检查。研究的主要终点是全因死亡率:共纳入326例手术,其中53%(n = 172)为新植入,47%(n = 154)为升级。两组的并发症发生率没有差异:新植入组:25.5%(n = 44);升级组:30.5%(n = 47):30.5%(n = 47),P = 0.78。以下方面的并发症发生率也相似:早期(p = 0.98)和晚期(p = 0.45)、感染性(p = 0.38)和非感染性(p = 0.82)、手术(p = 0.38)以及与设备或导联相关(p = 0.6)。升级组最常见的并发症是袋血肿(n = 9,5.8%),新生组最常见的并发症是气胸(n = 8,4.7%):结论:与从头植入 CRT-D 相比,升级手术的并发症发生率并不高。先前植入的心脏植入式电子设备不应限制 CRT-D 的植入。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Complications of cardiac resynchronization therapy implantation: De novo implants versus upgrades.

Background: Cardiac resynchronization therapy (CRT) is a well-established treatment of patients with advanced heart failure and electrical dyssynchrony. Implantation of those devices is in some cases associated with intervention on a formerly implanted system. The aim of this analysis was to compare the rate and type of complications of de novo implants and upgrades to CRT-D.

Methods: Retrospective data were collected from medical records, including 326 patients treated with CRT-D between 2015 and 2020. The following data were analyzed: procedure data including complications, demographics, co-morbidities, pharmacotherapy, and laboratory tests. The primary endpoint of the study was all-cause mortality.

Results: A total of 326 procedure were included, of which 53% (n = 172) were de novo implants and 47% (n = 154) were upgrades. The groups did not differ in the incidence of complications: in the de novo group: 25.5% (n = 44); in the upgrade group: 30.5% (n = 47), p = 0.78. The incidence of complications was also similar in respect of the following: early (p = 0.98) and late (p = 0.45), infectious (p = 0.38) and non-infectious (p = 0.82), surgical (p = 0.38) and device or lead related (p = 0.6). The most common complication in the upgrade group was pocket hematoma (n = 9, 5.8%) and in the de novo group pneumothorax (n = 8, 4.7%).

Conclusions: Upgrade procedures of are not associated with a higher percentage of complications than de novo implantations of CRT-D. Previously implanted cardiac implantable electronic device should not limit the implantation of CRT-Ds.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信