ST Genesia分析仪的评价。

IF 0.4 4区 医学 Q4 MEDICAL LABORATORY TECHNOLOGY
Nancy Modi Omasombo, Anne Demulder, Laurence Rozen
{"title":"ST Genesia分析仪的评价。","authors":"Nancy Modi Omasombo,&nbsp;Anne Demulder,&nbsp;Laurence Rozen","doi":"10.1684/abc.2022.1723","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Numerous studies have shown that thrombin generation test (TG) allows a better evaluation of the hemorrhagic and the thrombotic risks. The ST Genesia® is a benchtop, fully automated TG device. However, standardization of the technique and establishment of usual values are essential for its implementation in the routine laboratory.</p><p><strong>Objectives: </strong>We evaluated the fully automated TG analyzer ST Genesia ® and we aimed to determine usual values with special attention to the pediatric population.</p><p><strong>Methods: </strong>Two ST Genesia® reagents were evaluated (BleedscreenTM and ThromboscreenTM). Precision, stability, practicability and usual values according to age were established as well as the impact of freezing samples. The comparison between calibrated automated thrombogram (CAT) method and ST Genesia® was performed. TG parameters (ETP, peak, velocity, lag time, time to peak) were analyzed on both instruments. All the results were normalized toward a reference plasma.</p><p><strong>Results: </strong>Coefficient of variation associated with the repeatability and reproducibility of the QC norm low, and norm were less than 5% with both Thromboscreen and Bleedscreen reagents. We did not observe any statistical difference between results obtained on fresh or frozen samples. Usual values according to age and sex were established with special attention to the pediatric population.</p><p><strong>Conclusion: </strong>This technique provides a fully automated system, a strict control of temperature and the use of a reference plasma to obtain normalized results. This study is a prerequisite to future use of ST Genesia® in clinical application.</p>","PeriodicalId":7892,"journal":{"name":"Annales de biologie clinique","volume":"80 2","pages":"148-155"},"PeriodicalIF":0.4000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the analyzer ST Genesia.\",\"authors\":\"Nancy Modi Omasombo,&nbsp;Anne Demulder,&nbsp;Laurence Rozen\",\"doi\":\"10.1684/abc.2022.1723\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Numerous studies have shown that thrombin generation test (TG) allows a better evaluation of the hemorrhagic and the thrombotic risks. The ST Genesia® is a benchtop, fully automated TG device. However, standardization of the technique and establishment of usual values are essential for its implementation in the routine laboratory.</p><p><strong>Objectives: </strong>We evaluated the fully automated TG analyzer ST Genesia ® and we aimed to determine usual values with special attention to the pediatric population.</p><p><strong>Methods: </strong>Two ST Genesia® reagents were evaluated (BleedscreenTM and ThromboscreenTM). Precision, stability, practicability and usual values according to age were established as well as the impact of freezing samples. The comparison between calibrated automated thrombogram (CAT) method and ST Genesia® was performed. TG parameters (ETP, peak, velocity, lag time, time to peak) were analyzed on both instruments. All the results were normalized toward a reference plasma.</p><p><strong>Results: </strong>Coefficient of variation associated with the repeatability and reproducibility of the QC norm low, and norm were less than 5% with both Thromboscreen and Bleedscreen reagents. We did not observe any statistical difference between results obtained on fresh or frozen samples. Usual values according to age and sex were established with special attention to the pediatric population.</p><p><strong>Conclusion: </strong>This technique provides a fully automated system, a strict control of temperature and the use of a reference plasma to obtain normalized results. This study is a prerequisite to future use of ST Genesia® in clinical application.</p>\",\"PeriodicalId\":7892,\"journal\":{\"name\":\"Annales de biologie clinique\",\"volume\":\"80 2\",\"pages\":\"148-155\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2022-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annales de biologie clinique\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1684/abc.2022.1723\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annales de biologie clinique","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1684/abc.2022.1723","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:大量研究表明凝血酶生成试验(TG)可以更好地评估出血性和血栓形成的风险。ST Genesia®是一种台式全自动TG设备。然而,技术的标准化和标准值的建立是在常规实验室实施的必要条件。目的:我们评估了全自动TG分析仪ST Genesia®,我们的目的是确定通常的值,特别注意儿科人群。方法:对两种ST genia®试剂(出血筛查和血栓筛查)进行评估。建立了精密度、稳定性、实用性和按年龄划分的常用值以及样品冻结的影响。对校准后的自动血栓造影(CAT)方法和ST Genesia®进行比较。在两种仪器上分析TG参数(ETP、峰值、速度、滞后时间、到达峰值时间)。所有结果都归一化到参考等离子体。结果:与QC标准的重复性和再现性相关的变异系数较低,血栓筛查和出血筛查试剂的标准均小于5%。我们没有观察到在新鲜或冷冻样品上获得的结果有统计学差异。根据年龄和性别建立了通常的数值,并特别注意儿科人口。结论:该技术提供了一个完全自动化的系统,严格控制温度,并使用参考等离子体获得标准化的结果。这项研究是ST Genesia®未来临床应用的先决条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the analyzer ST Genesia.

Background: Numerous studies have shown that thrombin generation test (TG) allows a better evaluation of the hemorrhagic and the thrombotic risks. The ST Genesia® is a benchtop, fully automated TG device. However, standardization of the technique and establishment of usual values are essential for its implementation in the routine laboratory.

Objectives: We evaluated the fully automated TG analyzer ST Genesia ® and we aimed to determine usual values with special attention to the pediatric population.

Methods: Two ST Genesia® reagents were evaluated (BleedscreenTM and ThromboscreenTM). Precision, stability, practicability and usual values according to age were established as well as the impact of freezing samples. The comparison between calibrated automated thrombogram (CAT) method and ST Genesia® was performed. TG parameters (ETP, peak, velocity, lag time, time to peak) were analyzed on both instruments. All the results were normalized toward a reference plasma.

Results: Coefficient of variation associated with the repeatability and reproducibility of the QC norm low, and norm were less than 5% with both Thromboscreen and Bleedscreen reagents. We did not observe any statistical difference between results obtained on fresh or frozen samples. Usual values according to age and sex were established with special attention to the pediatric population.

Conclusion: This technique provides a fully automated system, a strict control of temperature and the use of a reference plasma to obtain normalized results. This study is a prerequisite to future use of ST Genesia® in clinical application.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Annales de biologie clinique
Annales de biologie clinique 医学-医学:研究与实验
CiteScore
0.80
自引率
20.00%
发文量
53
审稿时长
6-12 weeks
期刊介绍: Multidisciplinary information with direct relevance to everyday practice Annales de Biologie Clinique, the official journal of the French Society of Clinical Biology (SFBC), supports biologists in areas including continuing education, laboratory accreditation and technique validation. With original articles, abstracts and accounts of everyday practice, the journal provides details of advances in knowledge, techniques and equipment, as well as a forum for discussion open to the entire community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信