Xiaoying He, Qin He, Minjie Yuan, Zhi Fang, Kai Zhang, Tiepei Zhu, Wei Han
{"title":"形态学特征的评价:飞秒lasik皮瓣与SMILE帽,以及对角膜高阶像差的影响。","authors":"Xiaoying He, Qin He, Minjie Yuan, Zhi Fang, Kai Zhang, Tiepei Zhu, Wei Han","doi":"10.1007/s00417-022-05841-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study is to evaluate morphological features of corneal flap/cap and the correlations with corneal higher-order aberrations (HOAs) changes after femtosecond laser in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE).</p><p><strong>Methods: </strong>This was a retrospective study. Pre- and postoperative (1 and 3 months) corneal HOAs were assessed with Pentacam HR. The corneal flap/cap thickness at 32 points (± 1.5 mm, ± 2 mm, ± 2.5 mm, and ± 3 mm from the corneal vertex on meridian 0°/45°/90°/135°) were measured using anterior segment optical coherence tomography at 3 months postoperatively. Morphological features of corneal flap/cap including predictability (P), uniformity (U), and symmetry (S) were calculated and used for correlation analysis with corneal HOAs changes.</p><p><strong>Results: </strong>Eighty-six eyes (44 patients) and ninety-six eyes (50 patients) were involved in FS-LASIK and SMILE groups, respectively. Significant thicker corneal flap/cap than the predicted was observed at each measuring point and meridian in both groups (difference > 2.225 μm, the within-subject standard deviation over 6-mm optical zone). There was no statistically significant difference in predictability of corneal flap/cap thickness, while U<sub>6 mm</sub> (P < .0001), U<sub>0</sub> (P < .001), U<sub>45</sub> (P = .002), U<sub>90</sub> (P < .0001), U<sub>135</sub> (P = .004), S<sub>6 mm</sub> (P < .0001), S<sub>0</sub> (P < .001), and S<sub>90</sub> (P < .0001) over 6 mm zone were less in SMILE than in FS-LASIK. The changes of corneal tHOAs, Z (3, - 1), Z (3, 1), and SA were significantly correlated with morphological features of corneal flap/cap.</p><p><strong>Conclusion: </strong>Both FS-LASIK and SMILE had good predictability in flap or cap thickness, while the uniformity and symmetry of SMILE cap were better than FS-LASIK flap. The quality of flap/cap was closely associated with the changes of corneal HOAs.</p>","PeriodicalId":520634,"journal":{"name":"Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie","volume":" ","pages":"3993-4003"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of morphological features: femtosecond-LASIK flap vs. SMILE cap, and the effects on corneal higher-order aberrations.\",\"authors\":\"Xiaoying He, Qin He, Minjie Yuan, Zhi Fang, Kai Zhang, Tiepei Zhu, Wei Han\",\"doi\":\"10.1007/s00417-022-05841-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this study is to evaluate morphological features of corneal flap/cap and the correlations with corneal higher-order aberrations (HOAs) changes after femtosecond laser in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE).</p><p><strong>Methods: </strong>This was a retrospective study. Pre- and postoperative (1 and 3 months) corneal HOAs were assessed with Pentacam HR. The corneal flap/cap thickness at 32 points (± 1.5 mm, ± 2 mm, ± 2.5 mm, and ± 3 mm from the corneal vertex on meridian 0°/45°/90°/135°) were measured using anterior segment optical coherence tomography at 3 months postoperatively. Morphological features of corneal flap/cap including predictability (P), uniformity (U), and symmetry (S) were calculated and used for correlation analysis with corneal HOAs changes.</p><p><strong>Results: </strong>Eighty-six eyes (44 patients) and ninety-six eyes (50 patients) were involved in FS-LASIK and SMILE groups, respectively. Significant thicker corneal flap/cap than the predicted was observed at each measuring point and meridian in both groups (difference > 2.225 μm, the within-subject standard deviation over 6-mm optical zone). There was no statistically significant difference in predictability of corneal flap/cap thickness, while U<sub>6 mm</sub> (P < .0001), U<sub>0</sub> (P < .001), U<sub>45</sub> (P = .002), U<sub>90</sub> (P < .0001), U<sub>135</sub> (P = .004), S<sub>6 mm</sub> (P < .0001), S<sub>0</sub> (P < .001), and S<sub>90</sub> (P < .0001) over 6 mm zone were less in SMILE than in FS-LASIK. The changes of corneal tHOAs, Z (3, - 1), Z (3, 1), and SA were significantly correlated with morphological features of corneal flap/cap.</p><p><strong>Conclusion: </strong>Both FS-LASIK and SMILE had good predictability in flap or cap thickness, while the uniformity and symmetry of SMILE cap were better than FS-LASIK flap. The quality of flap/cap was closely associated with the changes of corneal HOAs.</p>\",\"PeriodicalId\":520634,\"journal\":{\"name\":\"Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie\",\"volume\":\" \",\"pages\":\"3993-4003\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00417-022-05841-0\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/9/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00417-022-05841-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/9/27 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of morphological features: femtosecond-LASIK flap vs. SMILE cap, and the effects on corneal higher-order aberrations.
Purpose: The aim of this study is to evaluate morphological features of corneal flap/cap and the correlations with corneal higher-order aberrations (HOAs) changes after femtosecond laser in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE).
Methods: This was a retrospective study. Pre- and postoperative (1 and 3 months) corneal HOAs were assessed with Pentacam HR. The corneal flap/cap thickness at 32 points (± 1.5 mm, ± 2 mm, ± 2.5 mm, and ± 3 mm from the corneal vertex on meridian 0°/45°/90°/135°) were measured using anterior segment optical coherence tomography at 3 months postoperatively. Morphological features of corneal flap/cap including predictability (P), uniformity (U), and symmetry (S) were calculated and used for correlation analysis with corneal HOAs changes.
Results: Eighty-six eyes (44 patients) and ninety-six eyes (50 patients) were involved in FS-LASIK and SMILE groups, respectively. Significant thicker corneal flap/cap than the predicted was observed at each measuring point and meridian in both groups (difference > 2.225 μm, the within-subject standard deviation over 6-mm optical zone). There was no statistically significant difference in predictability of corneal flap/cap thickness, while U6 mm (P < .0001), U0 (P < .001), U45 (P = .002), U90 (P < .0001), U135 (P = .004), S6 mm (P < .0001), S0 (P < .001), and S90 (P < .0001) over 6 mm zone were less in SMILE than in FS-LASIK. The changes of corneal tHOAs, Z (3, - 1), Z (3, 1), and SA were significantly correlated with morphological features of corneal flap/cap.
Conclusion: Both FS-LASIK and SMILE had good predictability in flap or cap thickness, while the uniformity and symmetry of SMILE cap were better than FS-LASIK flap. The quality of flap/cap was closely associated with the changes of corneal HOAs.