Kate Hunter, Niamh Gavin, Colin McQuade, Brendan Hogan, John Feeney
{"title":"99mTc-sestamibi显像中显示甲状旁腺瘤的SPECT/CT最佳时机。","authors":"Kate Hunter, Niamh Gavin, Colin McQuade, Brendan Hogan, John Feeney","doi":"10.5603/NMR.a2022.0020","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate preoperative localisation of the parathyroid adenoma is essential to achieve a minimally invasive parathyroidectomy. The purpose of this study was to validate and improve our single-isotope dual-phase parathyroid imaging protocol utilising 99mTechnetium-Sestamibi ([99mTc]MIBI). There has been no accepted gold standard evidence-based protocol regarding timing of single-photon emission computed tomography/computed tomography (SPECT/CT) acquisition in parathyroid imaging with resultant variation between centres. We sought to determine the optimum timing of SPECT/CT post administration of [99mTc]MIBI in the identification of parathyroid adenomas. We aimed to evaluate the efficacy of early and late SPECT/CT and to establish whether SPECT/CT demonstrates increased sensitivity over planar imaging.</p><p><strong>Material and methods: </strong>A sample of 36 patients with primary hyperparathyroidism underwent planar and SPECT/CT acquisition 15 minutes (early) and two hours (late) post [99mTc]MIBI administration. Two radionuclide radiologists reviewed the images and Fisher's exact Chi-squared statistic was used to evaluate the diagnostic performances of early versus late SPECT/CT acquisition and SPECT/CT versus planar imaging.</p><p><strong>Results: </strong>Twenty-one likely parathyroid adenomas were identified with a statistically superior diagnosis rate in the late SPECT/CT acquisition compared with both early SPECT/CT and planar imaging (p < 0.05). All adenomas diagnosed on early SPECT/CT acquisition were also identified on late SPECT/CT images.</p><p><strong>Conclusions: </strong>Single late phase SPECT/CT is significantly superior to early SPECT/CT in the identification of parathyroid adenomas. Late SPECT/CT improves diagnostic accuracy over planar acquisition. Imaging protocols should be revised to include late SPECT/CT acquisition. Early SPECT/CT acquisition can be eliminated from scan protocols with associated implications regarding reduced scan time and increased patient throughput.</p>","PeriodicalId":44718,"journal":{"name":"NUCLEAR MEDICINE REVIEW","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Optimal timing of SPECT/CT to demonstrate parathyroid adenomas in 99mTc-sestamibi scintigraphy.\",\"authors\":\"Kate Hunter, Niamh Gavin, Colin McQuade, Brendan Hogan, John Feeney\",\"doi\":\"10.5603/NMR.a2022.0020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Accurate preoperative localisation of the parathyroid adenoma is essential to achieve a minimally invasive parathyroidectomy. The purpose of this study was to validate and improve our single-isotope dual-phase parathyroid imaging protocol utilising 99mTechnetium-Sestamibi ([99mTc]MIBI). There has been no accepted gold standard evidence-based protocol regarding timing of single-photon emission computed tomography/computed tomography (SPECT/CT) acquisition in parathyroid imaging with resultant variation between centres. We sought to determine the optimum timing of SPECT/CT post administration of [99mTc]MIBI in the identification of parathyroid adenomas. We aimed to evaluate the efficacy of early and late SPECT/CT and to establish whether SPECT/CT demonstrates increased sensitivity over planar imaging.</p><p><strong>Material and methods: </strong>A sample of 36 patients with primary hyperparathyroidism underwent planar and SPECT/CT acquisition 15 minutes (early) and two hours (late) post [99mTc]MIBI administration. Two radionuclide radiologists reviewed the images and Fisher's exact Chi-squared statistic was used to evaluate the diagnostic performances of early versus late SPECT/CT acquisition and SPECT/CT versus planar imaging.</p><p><strong>Results: </strong>Twenty-one likely parathyroid adenomas were identified with a statistically superior diagnosis rate in the late SPECT/CT acquisition compared with both early SPECT/CT and planar imaging (p < 0.05). All adenomas diagnosed on early SPECT/CT acquisition were also identified on late SPECT/CT images.</p><p><strong>Conclusions: </strong>Single late phase SPECT/CT is significantly superior to early SPECT/CT in the identification of parathyroid adenomas. Late SPECT/CT improves diagnostic accuracy over planar acquisition. Imaging protocols should be revised to include late SPECT/CT acquisition. Early SPECT/CT acquisition can be eliminated from scan protocols with associated implications regarding reduced scan time and increased patient throughput.</p>\",\"PeriodicalId\":44718,\"journal\":{\"name\":\"NUCLEAR MEDICINE REVIEW\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"NUCLEAR MEDICINE REVIEW\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5603/NMR.a2022.0020\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"NUCLEAR MEDICINE REVIEW","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5603/NMR.a2022.0020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Optimal timing of SPECT/CT to demonstrate parathyroid adenomas in 99mTc-sestamibi scintigraphy.
Background: Accurate preoperative localisation of the parathyroid adenoma is essential to achieve a minimally invasive parathyroidectomy. The purpose of this study was to validate and improve our single-isotope dual-phase parathyroid imaging protocol utilising 99mTechnetium-Sestamibi ([99mTc]MIBI). There has been no accepted gold standard evidence-based protocol regarding timing of single-photon emission computed tomography/computed tomography (SPECT/CT) acquisition in parathyroid imaging with resultant variation between centres. We sought to determine the optimum timing of SPECT/CT post administration of [99mTc]MIBI in the identification of parathyroid adenomas. We aimed to evaluate the efficacy of early and late SPECT/CT and to establish whether SPECT/CT demonstrates increased sensitivity over planar imaging.
Material and methods: A sample of 36 patients with primary hyperparathyroidism underwent planar and SPECT/CT acquisition 15 minutes (early) and two hours (late) post [99mTc]MIBI administration. Two radionuclide radiologists reviewed the images and Fisher's exact Chi-squared statistic was used to evaluate the diagnostic performances of early versus late SPECT/CT acquisition and SPECT/CT versus planar imaging.
Results: Twenty-one likely parathyroid adenomas were identified with a statistically superior diagnosis rate in the late SPECT/CT acquisition compared with both early SPECT/CT and planar imaging (p < 0.05). All adenomas diagnosed on early SPECT/CT acquisition were also identified on late SPECT/CT images.
Conclusions: Single late phase SPECT/CT is significantly superior to early SPECT/CT in the identification of parathyroid adenomas. Late SPECT/CT improves diagnostic accuracy over planar acquisition. Imaging protocols should be revised to include late SPECT/CT acquisition. Early SPECT/CT acquisition can be eliminated from scan protocols with associated implications regarding reduced scan time and increased patient throughput.
期刊介绍:
Written in English, NMR is a biannual international periodical of scientific and educational profile. It is a journal of Bulgarian, Czech, Hungarian, Macedonian, Polish, Romanian, Russian, Slovak, Ukrainian and Yugoslav Societies of Nuclear Medicine. The periodical focuses on all nuclear medicine topics (diagnostics as well as therapy), and presents original experimental scientific papers, reviews, case studies, letters also news about symposia and congresses. NMR is indexed at Index Copernicus (7.41), Scopus, EMBASE, Index Medicus/Medline, Ministry of Education 2007 (4 pts.).