{"title":"Säntis闪电研究设施:前十年的总结及未来展望。","authors":"Farhad Rachidi, Marcos Rubinstein","doi":"10.1007/s00502-022-01031-2","DOIUrl":null,"url":null,"abstract":"<p><p>The Säntis Tower was instrumented in May 2010 to measure currents of lightning discharges striking the structure. Since then, the system has been recurrently updated and expanded. Presently, data associated with lightning striking the tower are collected at six different sites. The facility is equipped with a current measurement system, three electric field stations, an electrostatic field mill, two x‑ray sensors, a high-speed camera, and four slow cameras. This paper presents the latest measurement configuration at the facility. Other temporarily loaned instruments are also briefly described. Furthermore, examples of some of the data that have been gathered and analyzed are given, and an outlook as well as future plans for the facility are presented.</p>","PeriodicalId":93547,"journal":{"name":"Elektrotechnik und Informationstechnik : E & I","volume":"139 3","pages":"379-394"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9196207/pdf/","citationCount":"3","resultStr":"{\"title\":\"Säntis lightning research facility: a summary of the first ten years and future outlook.\",\"authors\":\"Farhad Rachidi, Marcos Rubinstein\",\"doi\":\"10.1007/s00502-022-01031-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The Säntis Tower was instrumented in May 2010 to measure currents of lightning discharges striking the structure. Since then, the system has been recurrently updated and expanded. Presently, data associated with lightning striking the tower are collected at six different sites. The facility is equipped with a current measurement system, three electric field stations, an electrostatic field mill, two x‑ray sensors, a high-speed camera, and four slow cameras. This paper presents the latest measurement configuration at the facility. Other temporarily loaned instruments are also briefly described. Furthermore, examples of some of the data that have been gathered and analyzed are given, and an outlook as well as future plans for the facility are presented.</p>\",\"PeriodicalId\":93547,\"journal\":{\"name\":\"Elektrotechnik und Informationstechnik : E & I\",\"volume\":\"139 3\",\"pages\":\"379-394\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9196207/pdf/\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Elektrotechnik und Informationstechnik : E & I\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s00502-022-01031-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/4/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Elektrotechnik und Informationstechnik : E & I","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s00502-022-01031-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/4/22 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
Säntis lightning research facility: a summary of the first ten years and future outlook.
The Säntis Tower was instrumented in May 2010 to measure currents of lightning discharges striking the structure. Since then, the system has been recurrently updated and expanded. Presently, data associated with lightning striking the tower are collected at six different sites. The facility is equipped with a current measurement system, three electric field stations, an electrostatic field mill, two x‑ray sensors, a high-speed camera, and four slow cameras. This paper presents the latest measurement configuration at the facility. Other temporarily loaned instruments are also briefly described. Furthermore, examples of some of the data that have been gathered and analyzed are given, and an outlook as well as future plans for the facility are presented.