利用implant Studio和MGUIDE对3d打印手术模板植入牙体的准确性进行研究。一项观察性研究。

IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Ioannis Fotopoulos, Theodoros Lillis, Eliza Panagiotidou, Ioannis Kapagiannidis, Ioannis Nazaroglou, Nikolaos Dabarakis
{"title":"利用implant Studio和MGUIDE对3d打印手术模板植入牙体的准确性进行研究。一项观察性研究。","authors":"Ioannis Fotopoulos,&nbsp;Theodoros Lillis,&nbsp;Eliza Panagiotidou,&nbsp;Ioannis Kapagiannidis,&nbsp;Ioannis Nazaroglou,&nbsp;Nikolaos Dabarakis","doi":"10.3290/j.ijcd.b2599735","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The purpose of the present study was to report early surgical template-related and postoperative complications of computer-guided implant placement and to evaluate its accuracy.</p><p><strong>Materials and methods: </strong>Data were collected retrospectively from records of patients who had undergone computer-guided implant surgery between 2016 and 2018. Incidence of early surgical template-related and postoperative complications was recorded. Accuracy of implant placement was evaluated by comparing the data from postoperative CBCT records with that from the preoperative virtual implant planning by using appropriate image registration software. Depth, coronal, apical, and angular deviations were measured.</p><p><strong>Results: </strong>A final number of 27 partially edentulous patients who received 52 implants with 31 static surgical templates were included in the study. All implants had been inserted in a fully guided manner using a flapless technique and following a one-stage approach. All implants were reported to have been successfully osseointegrated. Except for one template fracture, no other complication was recorded. The mean depth deviation was 0.57 ± 0.4 mm (95% CI 0.48 to 0.71 mm), the mean coronal deviation was 0.89 ± 0.7 mm (95% CI 0.73 to 1.07 mm), the mean apical deviation was 1.4 ± 1 mm (95% CI 1.16 to 1.71 mm), and the mean angular deviation was 2.74 ± 1.8 degrees (95% CI 2.29 to 3.26 degrees).</p><p><strong>Conclusion: </strong>The use of static surgical templates for fully guided implant placement demonstrated acceptable clinical performance. However, there are some factors affecting accuracy that should be considered during implant planning and surgery for further improvement of the technique. (Int J Comput Dent 2022;25(3):249-256; doi: 10.3290/j.ijcd.b2599735).</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"25 3","pages":"249-256"},"PeriodicalIF":1.8000,"publicationDate":"2022-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Accuracy of dental implant placement with 3D-printed surgical templates by using Implant Studio and MGUIDE. An observational study.\",\"authors\":\"Ioannis Fotopoulos,&nbsp;Theodoros Lillis,&nbsp;Eliza Panagiotidou,&nbsp;Ioannis Kapagiannidis,&nbsp;Ioannis Nazaroglou,&nbsp;Nikolaos Dabarakis\",\"doi\":\"10.3290/j.ijcd.b2599735\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>The purpose of the present study was to report early surgical template-related and postoperative complications of computer-guided implant placement and to evaluate its accuracy.</p><p><strong>Materials and methods: </strong>Data were collected retrospectively from records of patients who had undergone computer-guided implant surgery between 2016 and 2018. Incidence of early surgical template-related and postoperative complications was recorded. Accuracy of implant placement was evaluated by comparing the data from postoperative CBCT records with that from the preoperative virtual implant planning by using appropriate image registration software. Depth, coronal, apical, and angular deviations were measured.</p><p><strong>Results: </strong>A final number of 27 partially edentulous patients who received 52 implants with 31 static surgical templates were included in the study. All implants had been inserted in a fully guided manner using a flapless technique and following a one-stage approach. All implants were reported to have been successfully osseointegrated. Except for one template fracture, no other complication was recorded. The mean depth deviation was 0.57 ± 0.4 mm (95% CI 0.48 to 0.71 mm), the mean coronal deviation was 0.89 ± 0.7 mm (95% CI 0.73 to 1.07 mm), the mean apical deviation was 1.4 ± 1 mm (95% CI 1.16 to 1.71 mm), and the mean angular deviation was 2.74 ± 1.8 degrees (95% CI 2.29 to 3.26 degrees).</p><p><strong>Conclusion: </strong>The use of static surgical templates for fully guided implant placement demonstrated acceptable clinical performance. However, there are some factors affecting accuracy that should be considered during implant planning and surgery for further improvement of the technique. (Int J Comput Dent 2022;25(3):249-256; doi: 10.3290/j.ijcd.b2599735).</p>\",\"PeriodicalId\":48666,\"journal\":{\"name\":\"International Journal of Computerized Dentistry\",\"volume\":\"25 3\",\"pages\":\"249-256\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2022-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Computerized Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.ijcd.b2599735\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computerized Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.ijcd.b2599735","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

目的:本研究的目的是报告早期手术模板相关并发症和计算机引导植入物的术后并发症,并评估其准确性。材料与方法:回顾性收集2016 - 2018年行计算机引导种植体手术患者的资料。记录早期手术模板相关并发症及术后并发症的发生率。通过使用合适的图像配准软件,将术后CBCT记录的数据与术前虚拟种植计划的数据进行比较,评估种植体放置的准确性。测量深度、冠状、根尖和角度偏差。结果:27例部分无牙患者接受了52颗种植体和31个静态手术模板,最终纳入研究。所有植入物均采用无瓣技术和一期入路在完全引导下插入。据报道,所有种植体均成功骨整合。除1例模板骨折外,未见其他并发症。平均深度偏差为0.57±0.4 mm (95% CI 0.48 ~ 0.71 mm),平均冠状偏差为0.89±0.7 mm (95% CI 0.73 ~ 1.07 mm),平均根尖偏差为1.4±1 mm (95% CI 1.16 ~ 1.71 mm),平均角度偏差为2.74±1.8°(95% CI 2.29 ~ 3.26°)。结论:使用静态手术模板进行完全引导种植体置入具有良好的临床效果。然而,有一些影响准确性的因素,在种植计划和手术中应该考虑,以进一步提高技术。[J] .计算机工程学报;2009;25(3):249-256;doi: 10.3290 / j.ijcd.b2599735)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of dental implant placement with 3D-printed surgical templates by using Implant Studio and MGUIDE. An observational study.

Aim: The purpose of the present study was to report early surgical template-related and postoperative complications of computer-guided implant placement and to evaluate its accuracy.

Materials and methods: Data were collected retrospectively from records of patients who had undergone computer-guided implant surgery between 2016 and 2018. Incidence of early surgical template-related and postoperative complications was recorded. Accuracy of implant placement was evaluated by comparing the data from postoperative CBCT records with that from the preoperative virtual implant planning by using appropriate image registration software. Depth, coronal, apical, and angular deviations were measured.

Results: A final number of 27 partially edentulous patients who received 52 implants with 31 static surgical templates were included in the study. All implants had been inserted in a fully guided manner using a flapless technique and following a one-stage approach. All implants were reported to have been successfully osseointegrated. Except for one template fracture, no other complication was recorded. The mean depth deviation was 0.57 ± 0.4 mm (95% CI 0.48 to 0.71 mm), the mean coronal deviation was 0.89 ± 0.7 mm (95% CI 0.73 to 1.07 mm), the mean apical deviation was 1.4 ± 1 mm (95% CI 1.16 to 1.71 mm), and the mean angular deviation was 2.74 ± 1.8 degrees (95% CI 2.29 to 3.26 degrees).

Conclusion: The use of static surgical templates for fully guided implant placement demonstrated acceptable clinical performance. However, there are some factors affecting accuracy that should be considered during implant planning and surgery for further improvement of the technique. (Int J Comput Dent 2022;25(3):249-256; doi: 10.3290/j.ijcd.b2599735).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Computerized Dentistry
International Journal of Computerized Dentistry Dentistry-Dentistry (miscellaneous)
CiteScore
2.90
自引率
0.00%
发文量
49
期刊介绍: This journal explores the myriad innovations in the emerging field of computerized dentistry and how to integrate them into clinical practice. The bulk of the journal is devoted to the science of computer-assisted dentistry, with research articles and clinical reports on all aspects of computer-based diagnostic and therapeutic applications, with special emphasis placed on CAD/CAM and image-processing systems. Articles also address the use of computer-based communication to support patient care, assess the quality of care, and enhance clinical decision making. The journal is presented in a bilingual format, with each issue offering three types of articles: science-based, application-based, and national society reports.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信