Andrea Magrelli, Paolo Scannavini, Daniela D'Angelo, Chiara Maria Latini, Silvia Felli, Marco Di Nitto, Giuseppina Russo, Chiara Mastroianni, Giovanni Navalesi, Giuseppe Casale
{"title":"埃德蒙顿功能评估工具-2 (EFAT2-I)意大利语版的文化适应和测试。","authors":"Andrea Magrelli, Paolo Scannavini, Daniela D'Angelo, Chiara Maria Latini, Silvia Felli, Marco Di Nitto, Giuseppina Russo, Chiara Mastroianni, Giovanni Navalesi, Giuseppe Casale","doi":"10.1177/08258597211059304","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Physiotherapy in Palliative Care (PC) is effective in the management of a series of respiratory, circulatory and motor symptoms, and often has a positive impact on the patient's mood. The Edmonton Functional Assessment Tool (EFAT) is the only existing validated tool specifically designed for functional assessment in PC, and its use has been recommended in clinical practice. To date, no Italian version of the tool has been validated. The aim of this study was to translate, cross-culturally adapt, and evaluate the psychometric properties of the Italian version of the EFAT2.</p><p><strong>Method: </strong>After receiving formal permission from the author, Beaton guidelines for cross-cultural adaptation were followed, namely: (1) forward translation; (2) a multidisciplinary focus group (including 4 physiotherapists, 1 physician, 3 nurses, 1 occupational therapist, 1 psychologist) to assess semantic, idiomatic, experiential, and conceptual equivalence; (3) backward translation. The Content Validity Index (CVI) was used to assess content validity of the tool. Construct and concurrent validity were also evaluated. To evaluate the reliability of the EFAT2-I, reliability was measured using Cronbach alfa, item-total correlation, and Cohen's Kappa.</p><p><strong>Results: </strong>119 patients admitted to a Palliative Care Unit (Italy) agreed to participate in the study. The EFAT2-I mean score was 11.3, ranging from 0 to 30. Very good CVI scores were achieved, both in terms of single item validity (I-CVI) and of whole scale validity (S-CVI). Positive results were obtained from construct, concurrent validity assessment and measures of reliability.</p><p><strong>Discussion: </strong>The EFAT2-I showed good psychometric properties and can be used as a rehabilitation assessment tool in palliative care settings. The validation of the Italian version will allow comparison of different centres and palliative care facilities on national and international levels.</p>","PeriodicalId":51096,"journal":{"name":"Journal of Palliative Care","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cultural Adaptation and Testing of the Italian Version of the Edmonton Functional Assessment Tool-2 (EFAT2-I).\",\"authors\":\"Andrea Magrelli, Paolo Scannavini, Daniela D'Angelo, Chiara Maria Latini, Silvia Felli, Marco Di Nitto, Giuseppina Russo, Chiara Mastroianni, Giovanni Navalesi, Giuseppe Casale\",\"doi\":\"10.1177/08258597211059304\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Physiotherapy in Palliative Care (PC) is effective in the management of a series of respiratory, circulatory and motor symptoms, and often has a positive impact on the patient's mood. The Edmonton Functional Assessment Tool (EFAT) is the only existing validated tool specifically designed for functional assessment in PC, and its use has been recommended in clinical practice. To date, no Italian version of the tool has been validated. The aim of this study was to translate, cross-culturally adapt, and evaluate the psychometric properties of the Italian version of the EFAT2.</p><p><strong>Method: </strong>After receiving formal permission from the author, Beaton guidelines for cross-cultural adaptation were followed, namely: (1) forward translation; (2) a multidisciplinary focus group (including 4 physiotherapists, 1 physician, 3 nurses, 1 occupational therapist, 1 psychologist) to assess semantic, idiomatic, experiential, and conceptual equivalence; (3) backward translation. The Content Validity Index (CVI) was used to assess content validity of the tool. Construct and concurrent validity were also evaluated. To evaluate the reliability of the EFAT2-I, reliability was measured using Cronbach alfa, item-total correlation, and Cohen's Kappa.</p><p><strong>Results: </strong>119 patients admitted to a Palliative Care Unit (Italy) agreed to participate in the study. The EFAT2-I mean score was 11.3, ranging from 0 to 30. Very good CVI scores were achieved, both in terms of single item validity (I-CVI) and of whole scale validity (S-CVI). Positive results were obtained from construct, concurrent validity assessment and measures of reliability.</p><p><strong>Discussion: </strong>The EFAT2-I showed good psychometric properties and can be used as a rehabilitation assessment tool in palliative care settings. The validation of the Italian version will allow comparison of different centres and palliative care facilities on national and international levels.</p>\",\"PeriodicalId\":51096,\"journal\":{\"name\":\"Journal of Palliative Care\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Palliative Care\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/08258597211059304\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/12/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"HEALTH CARE SCIENCES & SERVICES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Palliative Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/08258597211059304","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/12/30 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0
摘要
背景:姑息治疗中的物理治疗(physical otherapy in Palliative Care, PC)对一系列呼吸、循环和运动症状的治疗是有效的,并且常常对患者的情绪产生积极的影响。埃德蒙顿功能评估工具(Edmonton Functional Assessment Tool, EFAT)是目前唯一经过验证的专门用于PC功能评估的工具,并已被推荐用于临床实践。到目前为止,该工具的意大利语版本尚未得到验证。本研究的目的是翻译、跨文化适应和评估意大利语版EFAT2的心理测量特性。方法:在获得作者的正式许可后,遵循Beaton的跨文化改编准则,即:(1)前向翻译;(2)多学科焦点小组(包括4名物理治疗师、1名内科医生、3名护士、1名职业治疗师、1名心理学家)评估语义、习惯用语、经验和概念等效性;(3)倒译。使用内容效度指数(CVI)来评估工具的内容效度。并对构念效度和并发效度进行了评估。为了评估EFAT2-I的信度,采用Cronbach alpha、项目-总相关和Cohen’s Kappa来测量信度。结果:入住姑息治疗病房(意大利)的119名患者同意参加研究。EFAT2-I平均得分为11.3,范围从0到30。在单项效度(I-CVI)和整体效度(S-CVI)方面均取得了非常好的CVI分数。从构念、并发效度评估和信度测量三个方面都得到了积极的结果。讨论:EFAT2-I显示出良好的心理测量特性,可作为姑息治疗环境中的康复评估工具。意大利版本的验证将允许在国家和国际层面上比较不同的中心和姑息治疗设施。
Cultural Adaptation and Testing of the Italian Version of the Edmonton Functional Assessment Tool-2 (EFAT2-I).
Background: Physiotherapy in Palliative Care (PC) is effective in the management of a series of respiratory, circulatory and motor symptoms, and often has a positive impact on the patient's mood. The Edmonton Functional Assessment Tool (EFAT) is the only existing validated tool specifically designed for functional assessment in PC, and its use has been recommended in clinical practice. To date, no Italian version of the tool has been validated. The aim of this study was to translate, cross-culturally adapt, and evaluate the psychometric properties of the Italian version of the EFAT2.
Method: After receiving formal permission from the author, Beaton guidelines for cross-cultural adaptation were followed, namely: (1) forward translation; (2) a multidisciplinary focus group (including 4 physiotherapists, 1 physician, 3 nurses, 1 occupational therapist, 1 psychologist) to assess semantic, idiomatic, experiential, and conceptual equivalence; (3) backward translation. The Content Validity Index (CVI) was used to assess content validity of the tool. Construct and concurrent validity were also evaluated. To evaluate the reliability of the EFAT2-I, reliability was measured using Cronbach alfa, item-total correlation, and Cohen's Kappa.
Results: 119 patients admitted to a Palliative Care Unit (Italy) agreed to participate in the study. The EFAT2-I mean score was 11.3, ranging from 0 to 30. Very good CVI scores were achieved, both in terms of single item validity (I-CVI) and of whole scale validity (S-CVI). Positive results were obtained from construct, concurrent validity assessment and measures of reliability.
Discussion: The EFAT2-I showed good psychometric properties and can be used as a rehabilitation assessment tool in palliative care settings. The validation of the Italian version will allow comparison of different centres and palliative care facilities on national and international levels.
期刊介绍:
The Journal of Palliative Care is a quarterly, peer-reviewed, international and interdisciplinary forum for practical, critical thought on palliative care and palliative medicine. JPC publishes high-quality original research, opinion papers/commentaries, narrative and humanities works, case reports/case series, and reports on international activities and comparative palliative care.