Rahul K Mukherjee, Manav Sohal, Nesan Shanmugam, Simon Pearse, Fadi Jouhra
{"title":"借助起搏和除颤器成功识别和区分房性和室性心律失常。","authors":"Rahul K Mukherjee, Manav Sohal, Nesan Shanmugam, Simon Pearse, Fadi Jouhra","doi":"10.15420/aer.2021.54","DOIUrl":null,"url":null,"abstract":"<p><p>The presence of supraventricular tachycardia is the leading cause of inappropriate shock in ICD recipients, and it can be a significant cause of morbidity, psychological distress and worsened clinical outcome. Modern pacing and ICD systems offer a number of discriminators that are integrated into algorithms to differentiate sustained ventricular tachycardia from supraventricular tachycardia. These algorithms can be adapted and optimised for each individual patient to ensure that only those arrhythmias that need treatment through the use of an ICD, are actually treated. This review summarises the single- and dual-chamber discriminators that can be used in the detection and classification of tachyarrhythmias.</p>","PeriodicalId":8412,"journal":{"name":"Arrhythmia & Electrophysiology Review","volume":" ","pages":"235-240"},"PeriodicalIF":2.6000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/82/fb/aer-10-235.PMC8785083.pdf","citationCount":"1","resultStr":"{\"title\":\"Successful Identification of and Discrimination Between Atrial and Ventricular Arrhythmia with the Aid of Pacing and Defibrillator Devices.\",\"authors\":\"Rahul K Mukherjee, Manav Sohal, Nesan Shanmugam, Simon Pearse, Fadi Jouhra\",\"doi\":\"10.15420/aer.2021.54\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The presence of supraventricular tachycardia is the leading cause of inappropriate shock in ICD recipients, and it can be a significant cause of morbidity, psychological distress and worsened clinical outcome. Modern pacing and ICD systems offer a number of discriminators that are integrated into algorithms to differentiate sustained ventricular tachycardia from supraventricular tachycardia. These algorithms can be adapted and optimised for each individual patient to ensure that only those arrhythmias that need treatment through the use of an ICD, are actually treated. This review summarises the single- and dual-chamber discriminators that can be used in the detection and classification of tachyarrhythmias.</p>\",\"PeriodicalId\":8412,\"journal\":{\"name\":\"Arrhythmia & Electrophysiology Review\",\"volume\":\" \",\"pages\":\"235-240\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2021-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/82/fb/aer-10-235.PMC8785083.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arrhythmia & Electrophysiology Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15420/aer.2021.54\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arrhythmia & Electrophysiology Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15420/aer.2021.54","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Successful Identification of and Discrimination Between Atrial and Ventricular Arrhythmia with the Aid of Pacing and Defibrillator Devices.
The presence of supraventricular tachycardia is the leading cause of inappropriate shock in ICD recipients, and it can be a significant cause of morbidity, psychological distress and worsened clinical outcome. Modern pacing and ICD systems offer a number of discriminators that are integrated into algorithms to differentiate sustained ventricular tachycardia from supraventricular tachycardia. These algorithms can be adapted and optimised for each individual patient to ensure that only those arrhythmias that need treatment through the use of an ICD, are actually treated. This review summarises the single- and dual-chamber discriminators that can be used in the detection and classification of tachyarrhythmias.