一种新型气管内管吸痰系统的评价。

0 CRITICAL CARE MEDICINE
Canadian Journal of Respiratory Therapy Pub Date : 2021-10-12 eCollection Date: 2021-01-01 DOI:10.29390/cjrt-2021-026
John D Davies, Yuh Chin Huang, Neil R MacIntyre
{"title":"一种新型气管内管吸痰系统的评价。","authors":"John D Davies,&nbsp;Yuh Chin Huang,&nbsp;Neil R MacIntyre","doi":"10.29390/cjrt-2021-026","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Accumulation of secretions in an endotracheal tube can increase the resistance to flow resulting in an increased patient work of breathing when the patient is interacting with the ventilator. Retained secretions can also serve as an infection risk. Standard suction catheters are limited in their ability to keep the lumen of the endotracheal tube clear. A novel closed-suction catheter has been introduced that incorporates a balloon at its distal end that, when inflated, physically scrapes secretions out of the endotracheal tube (CleanSweep catheter (CSC), Teleflex, Morrisville NC). We hypothesized that the CSC would be more efficient at removing secretions from inside the endotracheal tube than a standard suction catheter (SSC).</p><p><strong>Methods: </strong>We performed a bench study examining resistive pressures across different sizes of endotracheal tubes when cleaned by the CSC as compared with an SSC. This study was followed by a prospective crossover study again comparing the CSC with an SSC in intubated intensive care unit patients receiving mechanical ventilation and requiring frequent suctioning.</p><p><strong>Results: </strong>For the bench study the CSC was significantly better in reducing airway resistive pressures (<i>P</i> < 0.001). In the prospective crossover study the CSC over 2 h also removed significantly more secretions than the SSC (<i>P</i> < 0.05).</p><p><strong>Conclusion: </strong>Both our bench and crossover clinical study demonstrated improved clearance of secretions with the CSC vs an SSC. Further research is needed to ascertain the clinical outcome benefits of enhanced secretion removal.</p>","PeriodicalId":39373,"journal":{"name":"Canadian Journal of Respiratory Therapy","volume":"57 ","pages":"138-142"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d5/0e/cjrt-2021-026.PMC8509580.pdf","citationCount":"0","resultStr":"{\"title\":\"Evaluation of a novel endotracheal tube suctioning system incorporating an inflatable sweeper.\",\"authors\":\"John D Davies,&nbsp;Yuh Chin Huang,&nbsp;Neil R MacIntyre\",\"doi\":\"10.29390/cjrt-2021-026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Accumulation of secretions in an endotracheal tube can increase the resistance to flow resulting in an increased patient work of breathing when the patient is interacting with the ventilator. Retained secretions can also serve as an infection risk. Standard suction catheters are limited in their ability to keep the lumen of the endotracheal tube clear. A novel closed-suction catheter has been introduced that incorporates a balloon at its distal end that, when inflated, physically scrapes secretions out of the endotracheal tube (CleanSweep catheter (CSC), Teleflex, Morrisville NC). We hypothesized that the CSC would be more efficient at removing secretions from inside the endotracheal tube than a standard suction catheter (SSC).</p><p><strong>Methods: </strong>We performed a bench study examining resistive pressures across different sizes of endotracheal tubes when cleaned by the CSC as compared with an SSC. This study was followed by a prospective crossover study again comparing the CSC with an SSC in intubated intensive care unit patients receiving mechanical ventilation and requiring frequent suctioning.</p><p><strong>Results: </strong>For the bench study the CSC was significantly better in reducing airway resistive pressures (<i>P</i> < 0.001). In the prospective crossover study the CSC over 2 h also removed significantly more secretions than the SSC (<i>P</i> < 0.05).</p><p><strong>Conclusion: </strong>Both our bench and crossover clinical study demonstrated improved clearance of secretions with the CSC vs an SSC. Further research is needed to ascertain the clinical outcome benefits of enhanced secretion removal.</p>\",\"PeriodicalId\":39373,\"journal\":{\"name\":\"Canadian Journal of Respiratory Therapy\",\"volume\":\"57 \",\"pages\":\"138-142\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d5/0e/cjrt-2021-026.PMC8509580.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian Journal of Respiratory Therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29390/cjrt-2021-026\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"0\",\"JCRName\":\"CRITICAL CARE MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Journal of Respiratory Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29390/cjrt-2021-026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"0","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

简介:当患者与呼吸机相互作用时,气管内管中分泌物的积累会增加流动阻力,从而增加患者的呼吸功。残留的分泌物也有感染的风险。标准的吸引导管在保持气管内管腔清洁的能力上是有限的。一种新型的闭式吸引导管,在其远端包含一个气球,当充气时,物理刮除气管内管中的分泌物(清扫导管(CSC), Teleflex, Morrisville NC)。我们假设CSC在清除气管内导管内的分泌物方面比标准吸痰导管(SSC)更有效。方法:我们进行了一项台架研究,检查了不同尺寸的气管内管在CSC和SSC清洁时的阻力压力。在这项研究之后,又进行了一项前瞻性交叉研究,再次比较了在接受机械通气并需要频繁吸痰的插管重症监护病房患者中CSC和SSC。结果:在试验台研究中,CSC在降低气道阻力压方面有明显的优势(P < 0.001)。在前瞻性交叉研究中,CSC在2小时内清除的分泌物也明显多于SSC (P < 0.05)。结论:我们的实验和交叉临床研究都表明CSC与SSC相比可以改善分泌物的清除。需要进一步的研究来确定增强分泌物清除的临床结果益处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Evaluation of a novel endotracheal tube suctioning system incorporating an inflatable sweeper.

Evaluation of a novel endotracheal tube suctioning system incorporating an inflatable sweeper.

Introduction: Accumulation of secretions in an endotracheal tube can increase the resistance to flow resulting in an increased patient work of breathing when the patient is interacting with the ventilator. Retained secretions can also serve as an infection risk. Standard suction catheters are limited in their ability to keep the lumen of the endotracheal tube clear. A novel closed-suction catheter has been introduced that incorporates a balloon at its distal end that, when inflated, physically scrapes secretions out of the endotracheal tube (CleanSweep catheter (CSC), Teleflex, Morrisville NC). We hypothesized that the CSC would be more efficient at removing secretions from inside the endotracheal tube than a standard suction catheter (SSC).

Methods: We performed a bench study examining resistive pressures across different sizes of endotracheal tubes when cleaned by the CSC as compared with an SSC. This study was followed by a prospective crossover study again comparing the CSC with an SSC in intubated intensive care unit patients receiving mechanical ventilation and requiring frequent suctioning.

Results: For the bench study the CSC was significantly better in reducing airway resistive pressures (P < 0.001). In the prospective crossover study the CSC over 2 h also removed significantly more secretions than the SSC (P < 0.05).

Conclusion: Both our bench and crossover clinical study demonstrated improved clearance of secretions with the CSC vs an SSC. Further research is needed to ascertain the clinical outcome benefits of enhanced secretion removal.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Canadian Journal of Respiratory Therapy
Canadian Journal of Respiratory Therapy Health Professions-Health Professions (miscellaneous)
CiteScore
2.00
自引率
0.00%
发文量
34
期刊介绍: The CJRT is published four times a year and represents the interests of respiratory therapists nationally and internationally. The CJRT has been redesigned to act as an educational dissemination tool. The CJRT encourages submission of original articles, papers, commentaries, case studies, literature reviews and directed reading papers. Submissions can be sent to Rita Hansen.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信