天冬酰胺酶诱导的假性低钠血症,儿科患者病例驱动的工作策略。

IF 1.6 4区 医学 Q2 Medicine
Acta Clinica Belgica Pub Date : 2022-10-01 Epub Date: 2021-10-19 DOI:10.1080/17843286.2021.1992583
A Evenepoel, P Herroelen, K Lanckmans, J van der Werff Ten Bosch, M Martin, I Weets, A van Dalem
{"title":"天冬酰胺酶诱导的假性低钠血症,儿科患者病例驱动的工作策略。","authors":"A Evenepoel,&nbsp;P Herroelen,&nbsp;K Lanckmans,&nbsp;J van der Werff Ten Bosch,&nbsp;M Martin,&nbsp;I Weets,&nbsp;A van Dalem","doi":"10.1080/17843286.2021.1992583","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>When using indirect ion-selective electrode (ISE) methods, hypertriglyceridemia leads to pseudohyponatremia due to water displacement artifacts. Multiple strategies exist to minimize this interference. Our objective was to create a patient-friendly one-tube-fits-all testing setup without compromising the method robustness.</p><p><strong>Methods: </strong>Four strategies were evaluated in a single patient with hypertriglyceridemia. Additionally, the interchangeability between the Cobas 8000 and ABL Flex was evaluated on samples (n = 2274) with different total protein (TP) concentrations. Finally, a proof-of-concept (n = 40) was performed by re-measuring the routine sample with the ABL90 Flex.</p><p><strong>Results: </strong>ABL90 flex results and calculated sodium did not suffer from the presence of high triglyceride levels. We did not observe any significant differences between the three groups (P > 0.05) of sample types (arterial vs. venous plasma vs. venous whole blood after mixing up) nor for the analysers (Roche vs. ABL90 Flex). Passing-Bablok and Bland-Altman tests revealed interchangeability.</p><p><strong>Conclusion: </strong>In future cases of hypertriglyceridemia, 1500 mg/dL will be used as a preliminary threshold for reliable sodium determination. Routine Li-heparin samples can be used for accurate sodium determination without any need for extra arterial or venous blood gas tubes, offering a patient-friendly test setup for similar cases.</p>","PeriodicalId":7086,"journal":{"name":"Acta Clinica Belgica","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Asparaginase-induced pseudohyponatremia, a case-driven working strategy in pediatric patients.\",\"authors\":\"A Evenepoel,&nbsp;P Herroelen,&nbsp;K Lanckmans,&nbsp;J van der Werff Ten Bosch,&nbsp;M Martin,&nbsp;I Weets,&nbsp;A van Dalem\",\"doi\":\"10.1080/17843286.2021.1992583\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>When using indirect ion-selective electrode (ISE) methods, hypertriglyceridemia leads to pseudohyponatremia due to water displacement artifacts. Multiple strategies exist to minimize this interference. Our objective was to create a patient-friendly one-tube-fits-all testing setup without compromising the method robustness.</p><p><strong>Methods: </strong>Four strategies were evaluated in a single patient with hypertriglyceridemia. Additionally, the interchangeability between the Cobas 8000 and ABL Flex was evaluated on samples (n = 2274) with different total protein (TP) concentrations. Finally, a proof-of-concept (n = 40) was performed by re-measuring the routine sample with the ABL90 Flex.</p><p><strong>Results: </strong>ABL90 flex results and calculated sodium did not suffer from the presence of high triglyceride levels. We did not observe any significant differences between the three groups (P > 0.05) of sample types (arterial vs. venous plasma vs. venous whole blood after mixing up) nor for the analysers (Roche vs. ABL90 Flex). Passing-Bablok and Bland-Altman tests revealed interchangeability.</p><p><strong>Conclusion: </strong>In future cases of hypertriglyceridemia, 1500 mg/dL will be used as a preliminary threshold for reliable sodium determination. Routine Li-heparin samples can be used for accurate sodium determination without any need for extra arterial or venous blood gas tubes, offering a patient-friendly test setup for similar cases.</p>\",\"PeriodicalId\":7086,\"journal\":{\"name\":\"Acta Clinica Belgica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2022-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Clinica Belgica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/17843286.2021.1992583\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/10/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Clinica Belgica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/17843286.2021.1992583","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/10/19 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:当使用间接离子选择电极(ISE)方法时,由于水置换伪像,高甘油三酯血症导致假性低钠血症。存在多种策略来最小化这种干扰。我们的目标是在不影响方法稳健性的情况下,创建一个对患者友好的一管通的测试设置。方法:对1例高甘油三酯血症患者的4种治疗策略进行评估。此外,在不同总蛋白(TP)浓度的样品(n = 2274)上,对Cobas 8000和ABL Flex的互换性进行了评估。最后,通过使用ABL90 Flex重新测量常规样本进行概念验证(n = 40)。结果:ABL90 flex结果和计算的钠没有受到高甘油三酯水平的影响。我们没有观察到三组样品类型(混合后动脉血浆、静脉血浆、静脉全血)和分析仪(罗氏与ABL90 Flex)之间有任何显著差异(P > 0.05)。passingbablok和Bland-Altman测试揭示了互换性。结论:在未来的高甘油三酯血症病例中,1500mg /dL将作为可靠的钠测定的初步阈值。常规li -肝素样品可用于准确的钠测定,而无需额外的动脉或静脉血气管,为类似病例提供了患者友好的测试设置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Asparaginase-induced pseudohyponatremia, a case-driven working strategy in pediatric patients.

Objectives: When using indirect ion-selective electrode (ISE) methods, hypertriglyceridemia leads to pseudohyponatremia due to water displacement artifacts. Multiple strategies exist to minimize this interference. Our objective was to create a patient-friendly one-tube-fits-all testing setup without compromising the method robustness.

Methods: Four strategies were evaluated in a single patient with hypertriglyceridemia. Additionally, the interchangeability between the Cobas 8000 and ABL Flex was evaluated on samples (n = 2274) with different total protein (TP) concentrations. Finally, a proof-of-concept (n = 40) was performed by re-measuring the routine sample with the ABL90 Flex.

Results: ABL90 flex results and calculated sodium did not suffer from the presence of high triglyceride levels. We did not observe any significant differences between the three groups (P > 0.05) of sample types (arterial vs. venous plasma vs. venous whole blood after mixing up) nor for the analysers (Roche vs. ABL90 Flex). Passing-Bablok and Bland-Altman tests revealed interchangeability.

Conclusion: In future cases of hypertriglyceridemia, 1500 mg/dL will be used as a preliminary threshold for reliable sodium determination. Routine Li-heparin samples can be used for accurate sodium determination without any need for extra arterial or venous blood gas tubes, offering a patient-friendly test setup for similar cases.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Clinica Belgica
Acta Clinica Belgica 医学-医学:内科
CiteScore
2.90
自引率
0.00%
发文量
44
审稿时长
6-12 weeks
期刊介绍: Acta Clinica Belgica: International Journal of Clinical and Laboratory Medicine primarily publishes papers on clinical medicine, clinical chemistry, pathology and molecular biology, provided they describe results which contribute to our understanding of clinical problems or describe new methods applicable to clinical investigation. Readership includes physicians, pathologists, pharmacists and physicians working in non-academic and academic hospitals, practicing internal medicine and its subspecialties.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信