尽管父母双方的SARS-CoV-2检测均为阴性,但分娩后确诊新生儿SARS-CoV-2阳性的报告。

IF 0.8 Q4 PEDIATRICS
AJP Reports Pub Date : 2021-04-01 Epub Date: 2021-06-16 DOI:10.1055/s-0041-1728783
Benjamin R Harding, Farha Vora
{"title":"尽管父母双方的SARS-CoV-2检测均为阴性,但分娩后确诊新生儿SARS-CoV-2阳性的报告。","authors":"Benjamin R Harding,&nbsp;Farha Vora","doi":"10.1055/s-0041-1728783","DOIUrl":null,"url":null,"abstract":"<p><p>We present a case of a term infant born to an asymptomatic mother at a community hospital who required transfer to a local neonatal intensive care unit (NICU) immediately after birth for respiratory distress. The infant was tested for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) at 24 hours of life by reverse transcription polymerase chain reaction (RT-PCR) testing due to the absence of prenatal maternal COVID-19 testing and was found to be positive for SARS-CoV-2 at that time. A second RT-PCR test was obtained on the infant on day of life (DOL) 4 and was also positive, confirming an accurate diagnosis of COVID-19 disease in the infant. Both the mother and father remained asymptomatic and concomitantly tested negative for SARS-CoV-2 on two separate occasions. The infant subsequently clinically improved and was discharged without any complications. This case raises the potential concern for two unreported newborn issues related to COVID-19. First, the potential unreliability of negative maternal COVID-19 testing surrounding the time of delivery as it relates to routine newborn testing and isolation needs, and second, if the negative material testing was accurate, this raises the concern for a potential case of nosocomial COVID-19 infection within the first 24 hours of life.</p>","PeriodicalId":7645,"journal":{"name":"AJP Reports","volume":"11 2","pages":"e80-e83"},"PeriodicalIF":0.8000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/s-0041-1728783","citationCount":"2","resultStr":"{\"title\":\"Report of a Confirmed SARS-CoV-2 Positive Newborn after Delivery Despite Negative SARS-CoV-2 Testing on Both Parents.\",\"authors\":\"Benjamin R Harding,&nbsp;Farha Vora\",\"doi\":\"10.1055/s-0041-1728783\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We present a case of a term infant born to an asymptomatic mother at a community hospital who required transfer to a local neonatal intensive care unit (NICU) immediately after birth for respiratory distress. The infant was tested for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) at 24 hours of life by reverse transcription polymerase chain reaction (RT-PCR) testing due to the absence of prenatal maternal COVID-19 testing and was found to be positive for SARS-CoV-2 at that time. A second RT-PCR test was obtained on the infant on day of life (DOL) 4 and was also positive, confirming an accurate diagnosis of COVID-19 disease in the infant. Both the mother and father remained asymptomatic and concomitantly tested negative for SARS-CoV-2 on two separate occasions. The infant subsequently clinically improved and was discharged without any complications. This case raises the potential concern for two unreported newborn issues related to COVID-19. First, the potential unreliability of negative maternal COVID-19 testing surrounding the time of delivery as it relates to routine newborn testing and isolation needs, and second, if the negative material testing was accurate, this raises the concern for a potential case of nosocomial COVID-19 infection within the first 24 hours of life.</p>\",\"PeriodicalId\":7645,\"journal\":{\"name\":\"AJP Reports\",\"volume\":\"11 2\",\"pages\":\"e80-e83\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2021-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1055/s-0041-1728783\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AJP Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0041-1728783\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/6/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"PEDIATRICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AJP Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0041-1728783","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/6/16 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 2

摘要

我们提出一个病例足月婴儿出生的母亲无症状在社区医院谁需要转移到当地新生儿重症监护病房(NICU)出生后立即呼吸窘迫。由于未进行产前母体COVID-19检测,该婴儿在出生后24小时通过逆转录聚合酶链反应(RT-PCR)检测进行了严重急性呼吸综合征冠状病毒2 (SARS-CoV-2)检测,当时发现该婴儿SARS-CoV-2阳性。在婴儿出生第4天(DOL)进行了第二次RT-PCR检测,结果也呈阳性,证实了婴儿COVID-19疾病的准确诊断。母亲和父亲都没有出现症状,并在两次不同的情况下对SARS-CoV-2进行了阴性检测。婴儿随后临床好转,出院时无任何并发症。该病例引发了对与COVID-19相关的两个未报告新生儿问题的潜在关注。首先,产妇在分娩前后进行的COVID-19阴性检测可能不可靠,因为这涉及到常规新生儿检测和隔离需求;其次,如果阴性物质检测是准确的,这就会引起人们对出生后24小时内可能发生院内感染病例的担忧。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Report of a Confirmed SARS-CoV-2 Positive Newborn after Delivery Despite Negative SARS-CoV-2 Testing on Both Parents.

Report of a Confirmed SARS-CoV-2 Positive Newborn after Delivery Despite Negative SARS-CoV-2 Testing on Both Parents.

We present a case of a term infant born to an asymptomatic mother at a community hospital who required transfer to a local neonatal intensive care unit (NICU) immediately after birth for respiratory distress. The infant was tested for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) at 24 hours of life by reverse transcription polymerase chain reaction (RT-PCR) testing due to the absence of prenatal maternal COVID-19 testing and was found to be positive for SARS-CoV-2 at that time. A second RT-PCR test was obtained on the infant on day of life (DOL) 4 and was also positive, confirming an accurate diagnosis of COVID-19 disease in the infant. Both the mother and father remained asymptomatic and concomitantly tested negative for SARS-CoV-2 on two separate occasions. The infant subsequently clinically improved and was discharged without any complications. This case raises the potential concern for two unreported newborn issues related to COVID-19. First, the potential unreliability of negative maternal COVID-19 testing surrounding the time of delivery as it relates to routine newborn testing and isolation needs, and second, if the negative material testing was accurate, this raises the concern for a potential case of nosocomial COVID-19 infection within the first 24 hours of life.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
AJP Reports
AJP Reports PEDIATRICS-
CiteScore
2.20
自引率
0.00%
发文量
30
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信