非接触纳米细胞成像。

David Klenerman, Yuri Korchev, Pavel Novak, Andrew Shevchuk
{"title":"非接触纳米细胞成像。","authors":"David Klenerman,&nbsp;Yuri Korchev,&nbsp;Pavel Novak,&nbsp;Andrew Shevchuk","doi":"10.1146/annurev-anchem-091420-120101","DOIUrl":null,"url":null,"abstract":"<p><p>The reduction in ion current as a fine pipette approaches a cell surface allows the cell surface topography to be imaged, with nanoscale resolution, without contact with the delicate cell surface. A variety of different methods have been developed and refined to scan the topography of the dynamic cell surface at high resolution and speed. Measurement of cell topography can be complemented by performing local probing or mapping of the cell surface using the same pipette. This can be done by performing single-channel recording, applying force, delivering agonists, using pipettes fabricated to contain an electrochemical probe, or combining with fluorescence imaging. These methods in combination have great potential to image and map the surface of live cells at the nanoscale.</p>","PeriodicalId":72239,"journal":{"name":"Annual review of analytical chemistry (Palo Alto, Calif.)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Noncontact Nanoscale Imaging of Cells.\",\"authors\":\"David Klenerman,&nbsp;Yuri Korchev,&nbsp;Pavel Novak,&nbsp;Andrew Shevchuk\",\"doi\":\"10.1146/annurev-anchem-091420-120101\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The reduction in ion current as a fine pipette approaches a cell surface allows the cell surface topography to be imaged, with nanoscale resolution, without contact with the delicate cell surface. A variety of different methods have been developed and refined to scan the topography of the dynamic cell surface at high resolution and speed. Measurement of cell topography can be complemented by performing local probing or mapping of the cell surface using the same pipette. This can be done by performing single-channel recording, applying force, delivering agonists, using pipettes fabricated to contain an electrochemical probe, or combining with fluorescence imaging. These methods in combination have great potential to image and map the surface of live cells at the nanoscale.</p>\",\"PeriodicalId\":72239,\"journal\":{\"name\":\"Annual review of analytical chemistry (Palo Alto, Calif.)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annual review of analytical chemistry (Palo Alto, Calif.)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1146/annurev-anchem-091420-120101\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual review of analytical chemistry (Palo Alto, Calif.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1146/annurev-anchem-091420-120101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

当细移液管接近细胞表面时,离子电流的减少使细胞表面形貌成像具有纳米级分辨率,而不与微妙的细胞表面接触。各种不同的方法已经被开发和改进,以高分辨率和高速度扫描动态细胞表面的地形。细胞地形的测量可以通过使用相同的移液管进行局部探测或绘制细胞表面来补充。这可以通过执行单通道记录,施加力,输送激动剂,使用制造的含有电化学探针的移液器,或与荧光成像相结合来完成。这些方法的结合在纳米尺度上对活细胞表面进行成像和绘制具有很大的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Noncontact Nanoscale Imaging of Cells.

The reduction in ion current as a fine pipette approaches a cell surface allows the cell surface topography to be imaged, with nanoscale resolution, without contact with the delicate cell surface. A variety of different methods have been developed and refined to scan the topography of the dynamic cell surface at high resolution and speed. Measurement of cell topography can be complemented by performing local probing or mapping of the cell surface using the same pipette. This can be done by performing single-channel recording, applying force, delivering agonists, using pipettes fabricated to contain an electrochemical probe, or combining with fluorescence imaging. These methods in combination have great potential to image and map the surface of live cells at the nanoscale.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信