Marc-André d'Entremont, Gabriel Fortin, Thao Huynh, Étienne Croteau, Paul Farand, Samuel Lemaire-Paquette, Marie-Claude Brochu, Doan Hoa Do, Serge Lepage, Warner Mbuila Mampuya, Étienne L Couture, Michel Nguyen, Btissama Essadiqi
{"title":"二维斑点跟踪在跑步机负荷超声心动图后检测显著冠状动脉狭窄的可行性、可靠性和增量价值。","authors":"Marc-André d'Entremont, Gabriel Fortin, Thao Huynh, Étienne Croteau, Paul Farand, Samuel Lemaire-Paquette, Marie-Claude Brochu, Doan Hoa Do, Serge Lepage, Warner Mbuila Mampuya, Étienne L Couture, Michel Nguyen, Btissama Essadiqi","doi":"10.1186/s12947-021-00259-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Two-dimensional speckle-tracking echocardiography (STE) may help detect coronary artery disease (CAD) when combined with dobutamine stress echocardiography. However, few studies have explored STE with exercise stress echocardiography (ESE). We aimed to evaluate the feasibility, reliability, and incremental value of STE combined with treadmill ESE compared to treadmill ESE alone to detect CAD.</p><p><strong>Methods: </strong>We conducted a case-control study of all consecutive patients with abnormal ESE in 2018-2020 who subsequently underwent coronary angiography within a six-month interval. We 1:1 propensity score-matched these patients to those with a normal ESE. Two blinded operators generated a 17-segment bull's-eye map of longitudinal strain (LS). We utilized the mean differences between stress and baseline LS values in segments 13-17, segment 17, and segments 15-16 to create receiver operator curves for the overall examination, the left anterior descending artery (LAD), and the non-LAD territories, respectively.</p><p><strong>Results: </strong>We excluded 61 STEs from 201 (30.3%) eligible ESEs; 47 (23.4%) because of suboptimal image quality and 14 (7.0%) because of excessive heart rate variability precluding the calculation of a bull's-eye map. After matching, a total of 102 patients were included (51 patients in each group). In the group with abnormal ESE patients (mean age 66.4 years, 39.2% female), 64.7% had significant CAD (> 70% stenosis) at coronary angiogram. In the group with normal ESE patients (mean age 65.1 years, 35.3% female), 3.9% were diagnosed with a new significant coronary stenosis within one year. The intra-class correlation for global LS was 0.87 at rest and 0.92 at stress, and 0.84 at rest, and 0.89 at stress for the apical segments. The diagnostic accuracy of combining ESE and STE was superior to visual assessment alone for the overall examination (area under the curve (AUC) = 0.89 vs. 0.84, p = 0.025), the non-LAD territory (AUC = 0.83 vs. 0.70, p = 0.006), but not the LAD territory (AUC = 0.79 vs. 0.73, p = 0.11).</p><p><strong>Conclusions: </strong>Two-dimensional speckle-tracking combined with treadmill ESE is relatively feasible, reliable, and may provide incremental diagnostic value for the detection and localization of significant CAD.</p>","PeriodicalId":9613,"journal":{"name":"Cardiovascular Ultrasound","volume":"19 1","pages":"27"},"PeriodicalIF":1.9000,"publicationDate":"2021-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s12947-021-00259-w","citationCount":"2","resultStr":"{\"title\":\"The feasibility, reliability, and incremental value of two-dimensional speckle-tracking for the detection of significant coronary stenosis after treadmill stress echocardiography.\",\"authors\":\"Marc-André d'Entremont, Gabriel Fortin, Thao Huynh, Étienne Croteau, Paul Farand, Samuel Lemaire-Paquette, Marie-Claude Brochu, Doan Hoa Do, Serge Lepage, Warner Mbuila Mampuya, Étienne L Couture, Michel Nguyen, Btissama Essadiqi\",\"doi\":\"10.1186/s12947-021-00259-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Two-dimensional speckle-tracking echocardiography (STE) may help detect coronary artery disease (CAD) when combined with dobutamine stress echocardiography. However, few studies have explored STE with exercise stress echocardiography (ESE). We aimed to evaluate the feasibility, reliability, and incremental value of STE combined with treadmill ESE compared to treadmill ESE alone to detect CAD.</p><p><strong>Methods: </strong>We conducted a case-control study of all consecutive patients with abnormal ESE in 2018-2020 who subsequently underwent coronary angiography within a six-month interval. We 1:1 propensity score-matched these patients to those with a normal ESE. Two blinded operators generated a 17-segment bull's-eye map of longitudinal strain (LS). We utilized the mean differences between stress and baseline LS values in segments 13-17, segment 17, and segments 15-16 to create receiver operator curves for the overall examination, the left anterior descending artery (LAD), and the non-LAD territories, respectively.</p><p><strong>Results: </strong>We excluded 61 STEs from 201 (30.3%) eligible ESEs; 47 (23.4%) because of suboptimal image quality and 14 (7.0%) because of excessive heart rate variability precluding the calculation of a bull's-eye map. After matching, a total of 102 patients were included (51 patients in each group). In the group with abnormal ESE patients (mean age 66.4 years, 39.2% female), 64.7% had significant CAD (> 70% stenosis) at coronary angiogram. In the group with normal ESE patients (mean age 65.1 years, 35.3% female), 3.9% were diagnosed with a new significant coronary stenosis within one year. The intra-class correlation for global LS was 0.87 at rest and 0.92 at stress, and 0.84 at rest, and 0.89 at stress for the apical segments. The diagnostic accuracy of combining ESE and STE was superior to visual assessment alone for the overall examination (area under the curve (AUC) = 0.89 vs. 0.84, p = 0.025), the non-LAD territory (AUC = 0.83 vs. 0.70, p = 0.006), but not the LAD territory (AUC = 0.79 vs. 0.73, p = 0.11).</p><p><strong>Conclusions: </strong>Two-dimensional speckle-tracking combined with treadmill ESE is relatively feasible, reliable, and may provide incremental diagnostic value for the detection and localization of significant CAD.</p>\",\"PeriodicalId\":9613,\"journal\":{\"name\":\"Cardiovascular Ultrasound\",\"volume\":\"19 1\",\"pages\":\"27\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2021-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/s12947-021-00259-w\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Ultrasound\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12947-021-00259-w\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12947-021-00259-w","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 2
摘要
背景:二维斑点跟踪超声心动图(STE)联合多巴酚丁胺应激超声心动图可以帮助检测冠状动脉疾病(CAD)。然而,很少有研究探讨STE与运动应激超声心动图(ESE)。我们的目的是评估STE联合跑步机ESE检测CAD的可行性、可靠性和增量价值,与单独跑步机ESE相比。方法:我们对2018-2020年所有连续出现异常ESE的患者进行了病例对照研究,这些患者随后在6个月的间隔内接受了冠状动脉造影。我们将这些患者与正常ESE患者进行了1:1的倾向评分匹配。两名盲眼操作人员生成了17段纵向应变(LS)的靶心图。我们利用13-17节段、17节段和15-16节段的压力和基线LS值的平均差异,分别为整体检查、左前降支(LAD)和非前降支区域创建接受者算子曲线。结果:我们从201例符合条件的es中排除了61例(30.3%);47例(23.4%)是因为图像质量不理想,14例(7.0%)是因为过度的心率变异性妨碍了靶心图的计算。匹配后共纳入102例患者(每组51例)。在ESE异常组(平均年龄66.4岁,女性39.2%)中,64.7%的患者冠状动脉造影有明显的CAD(> 70%狭窄)。在正常ESE患者组(平均年龄65.1岁,女性35.3%),3.9%的患者在一年内被诊断为新的显著冠状动脉狭窄。在静息和应力下,总LS的类内相关系数分别为0.87和0.92;在静息和应力下,顶端段的类内相关系数分别为0.84和0.89。在全面检查中,ESE和STE联合诊断的准确性优于单独的视觉评估(曲线下面积(AUC) = 0.89 vs. 0.84, p = 0.025),非LAD区域(AUC = 0.83 vs. 0.70, p = 0.006),但LAD区域(AUC = 0.79 vs. 0.73, p = 0.11)。结论:二维散斑追踪联合跑步机ESE相对可行、可靠,可为重大CAD的发现和定位提供增量诊断价值。
The feasibility, reliability, and incremental value of two-dimensional speckle-tracking for the detection of significant coronary stenosis after treadmill stress echocardiography.
Background: Two-dimensional speckle-tracking echocardiography (STE) may help detect coronary artery disease (CAD) when combined with dobutamine stress echocardiography. However, few studies have explored STE with exercise stress echocardiography (ESE). We aimed to evaluate the feasibility, reliability, and incremental value of STE combined with treadmill ESE compared to treadmill ESE alone to detect CAD.
Methods: We conducted a case-control study of all consecutive patients with abnormal ESE in 2018-2020 who subsequently underwent coronary angiography within a six-month interval. We 1:1 propensity score-matched these patients to those with a normal ESE. Two blinded operators generated a 17-segment bull's-eye map of longitudinal strain (LS). We utilized the mean differences between stress and baseline LS values in segments 13-17, segment 17, and segments 15-16 to create receiver operator curves for the overall examination, the left anterior descending artery (LAD), and the non-LAD territories, respectively.
Results: We excluded 61 STEs from 201 (30.3%) eligible ESEs; 47 (23.4%) because of suboptimal image quality and 14 (7.0%) because of excessive heart rate variability precluding the calculation of a bull's-eye map. After matching, a total of 102 patients were included (51 patients in each group). In the group with abnormal ESE patients (mean age 66.4 years, 39.2% female), 64.7% had significant CAD (> 70% stenosis) at coronary angiogram. In the group with normal ESE patients (mean age 65.1 years, 35.3% female), 3.9% were diagnosed with a new significant coronary stenosis within one year. The intra-class correlation for global LS was 0.87 at rest and 0.92 at stress, and 0.84 at rest, and 0.89 at stress for the apical segments. The diagnostic accuracy of combining ESE and STE was superior to visual assessment alone for the overall examination (area under the curve (AUC) = 0.89 vs. 0.84, p = 0.025), the non-LAD territory (AUC = 0.83 vs. 0.70, p = 0.006), but not the LAD territory (AUC = 0.79 vs. 0.73, p = 0.11).
Conclusions: Two-dimensional speckle-tracking combined with treadmill ESE is relatively feasible, reliable, and may provide incremental diagnostic value for the detection and localization of significant CAD.
期刊介绍:
Cardiovascular Ultrasound is an online journal, publishing peer-reviewed: original research; authoritative reviews; case reports on challenging and/or unusual diagnostic aspects; and expert opinions on new techniques and technologies. We are particularly interested in articles that include relevant images or video files, which provide an additional dimension to published articles and enhance understanding.
As an open access journal, Cardiovascular Ultrasound ensures high visibility for authors in addition to providing an up-to-date and freely available resource for the community. The journal welcomes discussion, and provides a forum for publishing opinion and debate ranging from biology to engineering to clinical echocardiography, with both speed and versatility.