{"title":"amplure HBV定量试剂盒与Qiagen Artus HBV QS-RGQ法测定监测病例血浆中病毒DNA的比较","authors":"Ganesan Praveenkumar, Chaitali Nikam, Ragoori Venkata Ramana, Sengupta Caesar, Velumani Amruta, Ahmad Riyaj","doi":"10.1159/000515905","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Monitoring of hepatitis B virus (HBV) viral load has become an essential phase in the treatment of HBV. There are many commercial assays available for HBV viral load quantification. In this study, we have evaluated the performance characteristics of Amplisure® HBV Kit in comparison with the Qiagen artus HBV QS-RGQ kit for HBV DNA quantitation.</p><p><strong>Methods: </strong>Comparison of 2 methods was carried out on 200 clinical samples, 150 HBV DNA positive and 50 HBV DNA negative, by a reference method. Results obtained with Amplisure® HBV Kit (Amplisure HBV) were compared using the Qiagen artus HBV QS-RGQ assay results as the comparator method.</p><p><strong>Result: </strong>The overall performance of the Amplisure HBV compared with the comparator method shows positive and negative clinical agreement of 100 and 76%, respectively. Among the 12 qualitative discrepant samples, all positive with Amplisure HBV were sequenced and 10 were below comparator method's LOD. For 5 weak positives (-0.22 to 0.98 log IU/mL), the sequencing failed. The 7 other positives (0.48 to 1.89 log IU/mL) were confirmed positive by sequencing. Quantitative comparison gave an r2 of 0.967 with a mean log difference of 0.09 log10 IU/mL.</p><p><strong>Conclusion: </strong>This study shows that Amplisure® HBV Quantitative Kit shows comparable performance with artus HBV QS-RGQ assays and can be useful in management and therapeutic monitoring of HBV in a clinical practice.</p>","PeriodicalId":14547,"journal":{"name":"Intervirology","volume":"64 4","pages":"178-184"},"PeriodicalIF":3.2000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000515905","citationCount":"1","resultStr":"{\"title\":\"Comparison of the Amplisure HBV Quantitative Kit with the Qiagen Artus HBV QS-RGQ Assay for Quantifying Viral DNA in Plasma Samples of Monitoring Cases.\",\"authors\":\"Ganesan Praveenkumar, Chaitali Nikam, Ragoori Venkata Ramana, Sengupta Caesar, Velumani Amruta, Ahmad Riyaj\",\"doi\":\"10.1159/000515905\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Monitoring of hepatitis B virus (HBV) viral load has become an essential phase in the treatment of HBV. There are many commercial assays available for HBV viral load quantification. In this study, we have evaluated the performance characteristics of Amplisure® HBV Kit in comparison with the Qiagen artus HBV QS-RGQ kit for HBV DNA quantitation.</p><p><strong>Methods: </strong>Comparison of 2 methods was carried out on 200 clinical samples, 150 HBV DNA positive and 50 HBV DNA negative, by a reference method. Results obtained with Amplisure® HBV Kit (Amplisure HBV) were compared using the Qiagen artus HBV QS-RGQ assay results as the comparator method.</p><p><strong>Result: </strong>The overall performance of the Amplisure HBV compared with the comparator method shows positive and negative clinical agreement of 100 and 76%, respectively. Among the 12 qualitative discrepant samples, all positive with Amplisure HBV were sequenced and 10 were below comparator method's LOD. For 5 weak positives (-0.22 to 0.98 log IU/mL), the sequencing failed. The 7 other positives (0.48 to 1.89 log IU/mL) were confirmed positive by sequencing. Quantitative comparison gave an r2 of 0.967 with a mean log difference of 0.09 log10 IU/mL.</p><p><strong>Conclusion: </strong>This study shows that Amplisure® HBV Quantitative Kit shows comparable performance with artus HBV QS-RGQ assays and can be useful in management and therapeutic monitoring of HBV in a clinical practice.</p>\",\"PeriodicalId\":14547,\"journal\":{\"name\":\"Intervirology\",\"volume\":\"64 4\",\"pages\":\"178-184\"},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000515905\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Intervirology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000515905\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/5/21 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"VIROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Intervirology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000515905","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/5/21 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"VIROLOGY","Score":null,"Total":0}
Comparison of the Amplisure HBV Quantitative Kit with the Qiagen Artus HBV QS-RGQ Assay for Quantifying Viral DNA in Plasma Samples of Monitoring Cases.
Background: Monitoring of hepatitis B virus (HBV) viral load has become an essential phase in the treatment of HBV. There are many commercial assays available for HBV viral load quantification. In this study, we have evaluated the performance characteristics of Amplisure® HBV Kit in comparison with the Qiagen artus HBV QS-RGQ kit for HBV DNA quantitation.
Methods: Comparison of 2 methods was carried out on 200 clinical samples, 150 HBV DNA positive and 50 HBV DNA negative, by a reference method. Results obtained with Amplisure® HBV Kit (Amplisure HBV) were compared using the Qiagen artus HBV QS-RGQ assay results as the comparator method.
Result: The overall performance of the Amplisure HBV compared with the comparator method shows positive and negative clinical agreement of 100 and 76%, respectively. Among the 12 qualitative discrepant samples, all positive with Amplisure HBV were sequenced and 10 were below comparator method's LOD. For 5 weak positives (-0.22 to 0.98 log IU/mL), the sequencing failed. The 7 other positives (0.48 to 1.89 log IU/mL) were confirmed positive by sequencing. Quantitative comparison gave an r2 of 0.967 with a mean log difference of 0.09 log10 IU/mL.
Conclusion: This study shows that Amplisure® HBV Quantitative Kit shows comparable performance with artus HBV QS-RGQ assays and can be useful in management and therapeutic monitoring of HBV in a clinical practice.
期刊介绍:
''Intervirology'' covers progress in both basic and clinical virus research, and aims to provide a forum for the various disciplines within virology. Issues publishing original papers alternate with thematic issues, focusing on clearly defined topics. This thematic concentration serves to make timely reviews, research reports and controversy easily accessible to both specialists in the field and those who want to keep track of the latest developments outside their own area of interest. In addition to original papers, regular issues publish short communications and letters to the editor to provide readers with a forum for the exchange of ideas and comments. The scope encompasses work on the molecular biology of human and animal viruses, including genome organization and regulation, and the structure and function of viral proteins. The pathogenesis, immunology, diagnosis, epidemiology, prophylaxis and therapy of viral diseases are considered.