{"title":"在沉默和暴露于有节奏的声刺激下自主身体摇摆时,惯性感觉测量的并发有效性:一项初步研究。","authors":"Analina Emmanouil,&nbsp;Elissavet Rousanoglou,&nbsp;Anastasia Georgaki,&nbsp;Konstantinos Boudolos","doi":"10.1159/000514325","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The effect of rhythmic acoustic stimuli on body sway is of increasing interest due to their positive contribution when training or restoring the control of movement. Inertial sensors show promise as a portable, easier, and more affordable method compared to the force plate \"gold standard\" concerning the evaluation of postural sway. This study examined the concurrent validity of inertially sensed measures of voluntary body sway against those obtained with a force plate, in silence and while exposed to a rhythmic acoustic stimulus.</p><p><strong>Methods: </strong>Temporal (sway duration and variability) and spatial (trajectory length, variability, range, velocity, and area) body sway variables were extracted using an inertial sensor (at L5) in synchronization with a force plate, during anteroposterior body sway in silence and while exposed to a rhythmic acoustic stimulus (<i>n</i> = 18 young women; two 70-s trials in each condition). Statistics included bivariate correlations between the inertially sensed and the force plate measures, separately, in silence and with a rhythmic acoustic stimulus, as well as for the effect of the rhythmic acoustic stimulus (percentage difference from silence) (<i>p</i> ≤ 0.05, SPSS v25.0).</p><p><strong>Results: </strong>The inertially sensed measures demonstrated good-to-excellent concurrent validity for all temporal and almost all spatial variables, both in silence and with rhythmic acoustic stimulus (<i>r</i> > 0.75, <i>p</i> = 0.000), as well as for the rhythmic acoustic-stimulus effect (<i>r</i> > 0.75, <i>p</i> ≤ 0.05).</p><p><strong>Conclusion: </strong>The inertially sensed measures of the voluntary anteroposterior body sway demonstrated an overall good-to-excellent concurrent validity against those obtained with the force plate \"gold standard,\" both in the silence and the rhythmic acoustic stimulus conditions, as well as for the rhythmic acoustic-stimulus effect. The findings of this pilot study allow the recommendation of inertial sensing for the evaluation of postural control alterations when exposed to rhythmic acoustic stimuli, a condition of increasing interest due to the positive contribution of such stimuli when training or restoring the control of movement.</p>","PeriodicalId":11242,"journal":{"name":"Digital Biomarkers","volume":"5 1","pages":"65-73"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000514325","citationCount":"1","resultStr":"{\"title\":\"Concurrent Validity of Inertially Sensed Measures during Voluntary Body Sway in Silence and while Exposed to a Rhythmic Acoustic Stimulus: A Pilot Study.\",\"authors\":\"Analina Emmanouil,&nbsp;Elissavet Rousanoglou,&nbsp;Anastasia Georgaki,&nbsp;Konstantinos Boudolos\",\"doi\":\"10.1159/000514325\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The effect of rhythmic acoustic stimuli on body sway is of increasing interest due to their positive contribution when training or restoring the control of movement. Inertial sensors show promise as a portable, easier, and more affordable method compared to the force plate \\\"gold standard\\\" concerning the evaluation of postural sway. This study examined the concurrent validity of inertially sensed measures of voluntary body sway against those obtained with a force plate, in silence and while exposed to a rhythmic acoustic stimulus.</p><p><strong>Methods: </strong>Temporal (sway duration and variability) and spatial (trajectory length, variability, range, velocity, and area) body sway variables were extracted using an inertial sensor (at L5) in synchronization with a force plate, during anteroposterior body sway in silence and while exposed to a rhythmic acoustic stimulus (<i>n</i> = 18 young women; two 70-s trials in each condition). Statistics included bivariate correlations between the inertially sensed and the force plate measures, separately, in silence and with a rhythmic acoustic stimulus, as well as for the effect of the rhythmic acoustic stimulus (percentage difference from silence) (<i>p</i> ≤ 0.05, SPSS v25.0).</p><p><strong>Results: </strong>The inertially sensed measures demonstrated good-to-excellent concurrent validity for all temporal and almost all spatial variables, both in silence and with rhythmic acoustic stimulus (<i>r</i> > 0.75, <i>p</i> = 0.000), as well as for the rhythmic acoustic-stimulus effect (<i>r</i> > 0.75, <i>p</i> ≤ 0.05).</p><p><strong>Conclusion: </strong>The inertially sensed measures of the voluntary anteroposterior body sway demonstrated an overall good-to-excellent concurrent validity against those obtained with the force plate \\\"gold standard,\\\" both in the silence and the rhythmic acoustic stimulus conditions, as well as for the rhythmic acoustic-stimulus effect. The findings of this pilot study allow the recommendation of inertial sensing for the evaluation of postural control alterations when exposed to rhythmic acoustic stimuli, a condition of increasing interest due to the positive contribution of such stimuli when training or restoring the control of movement.</p>\",\"PeriodicalId\":11242,\"journal\":{\"name\":\"Digital Biomarkers\",\"volume\":\"5 1\",\"pages\":\"65-73\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000514325\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digital Biomarkers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000514325\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"Computer Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digital Biomarkers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000514325","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"Computer Science","Score":null,"Total":0}
引用次数: 1

摘要

导读:有节奏的声刺激对身体摇摆的影响越来越引起人们的兴趣,因为它们在训练或恢复运动控制方面有积极的贡献。相对于测力板的“黄金标准”,惯性传感器作为一种便携式、更简单、更实惠的评估姿势摇摆的方法被看好。本研究考察了在沉默和暴露于有节奏的声音刺激下,自愿性身体摇摆的惯性感知测量与力板测量的同时有效性。方法:使用惯性传感器(L5)与测力板同步提取时间(摇摆持续时间和可变性)和空间(轨迹长度、可变性、范围、速度和面积)的身体摇摆变量,同时暴露于有节奏的声音刺激(n = 18名年轻女性;在每种情况下进行两次70-s试验)。统计包括静声和有节奏声刺激下的惯性感知和力板测量之间的双变量相关性,以及有节奏声刺激的效果(与静声的百分比差异)(p≤0.05,SPSS v25.0)。结果:惯性感知测量对所有时间变量和几乎所有空间变量的并发效度均为良好至极好,无论是沉默还是有节奏声刺激(r > 0.75, p = 0.000),以及节奏声刺激效应(r > 0.75, p≤0.05)。结论:与力板“金标准”相比,自主前后体摇摆的惯性感测量结果在沉默和节奏性声刺激条件下以及节奏性声刺激效应下均表现出良好到优秀的同时效度。这项初步研究的结果允许惯性传感在暴露于有节奏的声音刺激时评估姿势控制变化的推荐,由于这种刺激在训练或恢复运动控制时的积极贡献,这种情况越来越有趣。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Concurrent Validity of Inertially Sensed Measures during Voluntary Body Sway in Silence and while Exposed to a Rhythmic Acoustic Stimulus: A Pilot Study.

Introduction: The effect of rhythmic acoustic stimuli on body sway is of increasing interest due to their positive contribution when training or restoring the control of movement. Inertial sensors show promise as a portable, easier, and more affordable method compared to the force plate "gold standard" concerning the evaluation of postural sway. This study examined the concurrent validity of inertially sensed measures of voluntary body sway against those obtained with a force plate, in silence and while exposed to a rhythmic acoustic stimulus.

Methods: Temporal (sway duration and variability) and spatial (trajectory length, variability, range, velocity, and area) body sway variables were extracted using an inertial sensor (at L5) in synchronization with a force plate, during anteroposterior body sway in silence and while exposed to a rhythmic acoustic stimulus (n = 18 young women; two 70-s trials in each condition). Statistics included bivariate correlations between the inertially sensed and the force plate measures, separately, in silence and with a rhythmic acoustic stimulus, as well as for the effect of the rhythmic acoustic stimulus (percentage difference from silence) (p ≤ 0.05, SPSS v25.0).

Results: The inertially sensed measures demonstrated good-to-excellent concurrent validity for all temporal and almost all spatial variables, both in silence and with rhythmic acoustic stimulus (r > 0.75, p = 0.000), as well as for the rhythmic acoustic-stimulus effect (r > 0.75, p ≤ 0.05).

Conclusion: The inertially sensed measures of the voluntary anteroposterior body sway demonstrated an overall good-to-excellent concurrent validity against those obtained with the force plate "gold standard," both in the silence and the rhythmic acoustic stimulus conditions, as well as for the rhythmic acoustic-stimulus effect. The findings of this pilot study allow the recommendation of inertial sensing for the evaluation of postural control alterations when exposed to rhythmic acoustic stimuli, a condition of increasing interest due to the positive contribution of such stimuli when training or restoring the control of movement.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Digital Biomarkers
Digital Biomarkers Medicine-Medicine (miscellaneous)
CiteScore
10.60
自引率
0.00%
发文量
12
审稿时长
23 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信