动态高密度功能底物定位改善缺血性室性心动过速消融的疗效:感觉协议功能底物定位和其他功能定位技术。

IF 2.6 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Nikolaos Papageorgiou, Neil T Srinivasan
{"title":"动态高密度功能底物定位改善缺血性室性心动过速消融的疗效:感觉协议功能底物定位和其他功能定位技术。","authors":"Nikolaos Papageorgiou,&nbsp;Neil T Srinivasan","doi":"10.15420/aer.2020.28","DOIUrl":null,"url":null,"abstract":"<p><p>Post-infarct-related ventricular tachycardia (VT) occurs due to reentry over surviving fibres within ventricular scar tissue. The mapping and ablation of patients in VT remains a challenge when VT is poorly tolerated and in cases in which VT is non-sustained or not inducible. Conventional substrate mapping techniques are limited by the ambiguity of substrate characterisation methods and the variety of mapping tools, which may record signals differently based on their bipolar spacing and electrode size. Real world data suggest that outcomes from VT ablation remain poor in terms of freedom from recurrent therapy using conventional techniques. Functional substrate mapping techniques, such as single extrastimulus protocol mapping, identify regions of unmasked delayed potentials, which, by nature of their dynamic and functional components, may play a critical role in sustaining VT. These methods may improve substrate mapping of VT, potentially making ablation safer and more reproducible, and thereby improving the outcomes. Further large-scale studies are needed.</p>","PeriodicalId":8412,"journal":{"name":"Arrhythmia & Electrophysiology Review","volume":"10 1","pages":"38-44"},"PeriodicalIF":2.6000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/4b/37/aer-10-38.PMC8076974.pdf","citationCount":"2","resultStr":"{\"title\":\"Dynamic High-density Functional Substrate Mapping Improves Outcomes in Ischaemic Ventricular Tachycardia Ablation: Sense Protocol Functional Substrate Mapping and Other Functional Mapping Techniques.\",\"authors\":\"Nikolaos Papageorgiou,&nbsp;Neil T Srinivasan\",\"doi\":\"10.15420/aer.2020.28\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Post-infarct-related ventricular tachycardia (VT) occurs due to reentry over surviving fibres within ventricular scar tissue. The mapping and ablation of patients in VT remains a challenge when VT is poorly tolerated and in cases in which VT is non-sustained or not inducible. Conventional substrate mapping techniques are limited by the ambiguity of substrate characterisation methods and the variety of mapping tools, which may record signals differently based on their bipolar spacing and electrode size. Real world data suggest that outcomes from VT ablation remain poor in terms of freedom from recurrent therapy using conventional techniques. Functional substrate mapping techniques, such as single extrastimulus protocol mapping, identify regions of unmasked delayed potentials, which, by nature of their dynamic and functional components, may play a critical role in sustaining VT. These methods may improve substrate mapping of VT, potentially making ablation safer and more reproducible, and thereby improving the outcomes. Further large-scale studies are needed.</p>\",\"PeriodicalId\":8412,\"journal\":{\"name\":\"Arrhythmia & Electrophysiology Review\",\"volume\":\"10 1\",\"pages\":\"38-44\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2021-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/4b/37/aer-10-38.PMC8076974.pdf\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Arrhythmia & Electrophysiology Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15420/aer.2020.28\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arrhythmia & Electrophysiology Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15420/aer.2020.28","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 2

摘要

梗死后相关性室性心动过速(VT)的发生是由于心室瘢痕组织内残存的纤维重新进入所致。当室性心动过速耐受性差、室性心动过速非持续性或不可诱导时,对室性心动过速患者的定位和消融仍然是一个挑战。传统的衬底测绘技术受到衬底表征方法的模糊性和各种测绘工具的限制,这些工具可能根据其双极间距和电极尺寸记录不同的信号。现实世界的数据表明,就使用传统技术进行复发治疗而言,室性心动过速消融的结果仍然很差。功能底物映射技术,如单刺激外协议映射,识别未被掩盖的延迟电位区域,其动态和功能成分的性质可能在维持VT中发挥关键作用。这些方法可能改善VT的底物映射,可能使消融更安全、更可重复,从而改善结果。需要进一步的大规模研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Dynamic High-density Functional Substrate Mapping Improves Outcomes in Ischaemic Ventricular Tachycardia Ablation: Sense Protocol Functional Substrate Mapping and Other Functional Mapping Techniques.

Dynamic High-density Functional Substrate Mapping Improves Outcomes in Ischaemic Ventricular Tachycardia Ablation: Sense Protocol Functional Substrate Mapping and Other Functional Mapping Techniques.

Dynamic High-density Functional Substrate Mapping Improves Outcomes in Ischaemic Ventricular Tachycardia Ablation: Sense Protocol Functional Substrate Mapping and Other Functional Mapping Techniques.

Dynamic High-density Functional Substrate Mapping Improves Outcomes in Ischaemic Ventricular Tachycardia Ablation: Sense Protocol Functional Substrate Mapping and Other Functional Mapping Techniques.

Post-infarct-related ventricular tachycardia (VT) occurs due to reentry over surviving fibres within ventricular scar tissue. The mapping and ablation of patients in VT remains a challenge when VT is poorly tolerated and in cases in which VT is non-sustained or not inducible. Conventional substrate mapping techniques are limited by the ambiguity of substrate characterisation methods and the variety of mapping tools, which may record signals differently based on their bipolar spacing and electrode size. Real world data suggest that outcomes from VT ablation remain poor in terms of freedom from recurrent therapy using conventional techniques. Functional substrate mapping techniques, such as single extrastimulus protocol mapping, identify regions of unmasked delayed potentials, which, by nature of their dynamic and functional components, may play a critical role in sustaining VT. These methods may improve substrate mapping of VT, potentially making ablation safer and more reproducible, and thereby improving the outcomes. Further large-scale studies are needed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Arrhythmia & Electrophysiology Review
Arrhythmia & Electrophysiology Review CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
5.10
自引率
6.70%
发文量
22
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信