玻璃离子基修复材料聚合过程中乳牙牙髓腔温度升高。

IF 0.9 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Cigdem Buyukkok, Arife Kaptan
{"title":"玻璃离子基修复材料聚合过程中乳牙牙髓腔温度升高。","authors":"Cigdem Buyukkok,&nbsp;Arife Kaptan","doi":"10.26650/eor.20210024","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the temperature changes in primary teeth pulp chambers of different dentin thicknesses during polymerization of four glass ionomer-based restorative materials.</p><p><strong>Materials and methods: </strong>Eighty extracted, caries‑free, primary molars were prepared as standardized Class I occlusal cavities with dentin thicknesses of 1 mm and 2 mm. Four glass ionomerbased restorative materials, Dyract XP, Photac Fil Quick Aplicap, Fuji II LC, and GCP Glass Fill, were placed in the cavities and cured with two light-curing units. Temperature increases (initial temperature, 37°C) in the pulp chamber during polymerization were recorded by a J-type thermocouple in a pulpal microcirculation set-up. The data were analyzed with Variance analyses and Tukey tests.</p><p><strong>Results: </strong>The temperatures recorded in samples with dentin thicknesses of 1 mm and 2 mm exhibited statistically significant differences (p<0.05). The GCP Glass Fill group exhibited the highest temperature increases for both dentin thicknesses (p<0.05). The other groups were not statistically different but the Dyract XP group exhibited the least temperature change.</p><p><strong>Conclusion: </strong>The highest temperature changes were observed for 1 mm dentin thickness. All temperature increases during polymerizations and setting reactions were lower than the corresponding critical values 5.5°C.</p>","PeriodicalId":41993,"journal":{"name":"European Oral Research","volume":"55 1","pages":"28-33"},"PeriodicalIF":0.9000,"publicationDate":"2021-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/15/59/eor-055-028.PMC8055261.pdf","citationCount":"2","resultStr":"{\"title\":\"Temperature increases in primary teeth pulp chamber during polymerization of glass ionomer-based restorative materials.\",\"authors\":\"Cigdem Buyukkok,&nbsp;Arife Kaptan\",\"doi\":\"10.26650/eor.20210024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the temperature changes in primary teeth pulp chambers of different dentin thicknesses during polymerization of four glass ionomer-based restorative materials.</p><p><strong>Materials and methods: </strong>Eighty extracted, caries‑free, primary molars were prepared as standardized Class I occlusal cavities with dentin thicknesses of 1 mm and 2 mm. Four glass ionomerbased restorative materials, Dyract XP, Photac Fil Quick Aplicap, Fuji II LC, and GCP Glass Fill, were placed in the cavities and cured with two light-curing units. Temperature increases (initial temperature, 37°C) in the pulp chamber during polymerization were recorded by a J-type thermocouple in a pulpal microcirculation set-up. The data were analyzed with Variance analyses and Tukey tests.</p><p><strong>Results: </strong>The temperatures recorded in samples with dentin thicknesses of 1 mm and 2 mm exhibited statistically significant differences (p<0.05). The GCP Glass Fill group exhibited the highest temperature increases for both dentin thicknesses (p<0.05). The other groups were not statistically different but the Dyract XP group exhibited the least temperature change.</p><p><strong>Conclusion: </strong>The highest temperature changes were observed for 1 mm dentin thickness. All temperature increases during polymerizations and setting reactions were lower than the corresponding critical values 5.5°C.</p>\",\"PeriodicalId\":41993,\"journal\":{\"name\":\"European Oral Research\",\"volume\":\"55 1\",\"pages\":\"28-33\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2021-01-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/15/59/eor-055-028.PMC8055261.pdf\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Oral Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26650/eor.20210024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Oral Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26650/eor.20210024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 2

摘要

目的:评价四种玻璃离子基修复材料聚合过程中不同牙本质厚度乳牙牙髓腔内温度的变化。材料与方法:拔牙无龋的初生磨牙80颗,牙本质厚度分别为1mm和2mm,作为标准化的I类牙合腔。四种基于玻璃离子的修复材料,Dyract XP, Photac Fil Quick apply, Fuji II LC和GCP glass Fill,放置在空腔中并用两个光固化单元进行固化。通过j型热电偶在牙髓微循环装置中记录聚合过程中牙髓腔内的温度升高(初始温度,37℃)。采用方差分析和Tukey检验对数据进行分析。结果:牙本质厚度为1 mm和2 mm的样品所记录的温度差异有统计学意义(p)结论:牙本质厚度为1 mm时温度变化最大。在聚合和固化反应过程中,所有的温度升高都低于相应的临界值5.5℃。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Temperature increases in primary teeth pulp chamber during polymerization of glass ionomer-based restorative materials.

Temperature increases in primary teeth pulp chamber during polymerization of glass ionomer-based restorative materials.

Purpose: To evaluate the temperature changes in primary teeth pulp chambers of different dentin thicknesses during polymerization of four glass ionomer-based restorative materials.

Materials and methods: Eighty extracted, caries‑free, primary molars were prepared as standardized Class I occlusal cavities with dentin thicknesses of 1 mm and 2 mm. Four glass ionomerbased restorative materials, Dyract XP, Photac Fil Quick Aplicap, Fuji II LC, and GCP Glass Fill, were placed in the cavities and cured with two light-curing units. Temperature increases (initial temperature, 37°C) in the pulp chamber during polymerization were recorded by a J-type thermocouple in a pulpal microcirculation set-up. The data were analyzed with Variance analyses and Tukey tests.

Results: The temperatures recorded in samples with dentin thicknesses of 1 mm and 2 mm exhibited statistically significant differences (p<0.05). The GCP Glass Fill group exhibited the highest temperature increases for both dentin thicknesses (p<0.05). The other groups were not statistically different but the Dyract XP group exhibited the least temperature change.

Conclusion: The highest temperature changes were observed for 1 mm dentin thickness. All temperature increases during polymerizations and setting reactions were lower than the corresponding critical values 5.5°C.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Oral Research
European Oral Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.60
自引率
0.00%
发文量
23
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信