{"title":"眼周皮肤升温促进体热损失和睡眠:一项随机安慰剂对照研究。","authors":"Tomohisa Ichiba, Masahiro Suzuki, Sayaka Aritake-Okada, Makoto Uchiyama","doi":"10.1038/s41598-020-77192-x","DOIUrl":null,"url":null,"abstract":"<p><p>Periocular skin warming was reported to have favorable effects on subjective and objective sleep quality. We hypothesized that enhancing body heat loss by periocular skin warming would reduce sleep onset and improve sleep quality. Eighteen healthy volunteers were asked to maintain wakefulness with their eyes closed for 60 min after applying either a warming or sham eye mask, followed by a 60-min sleep period. Compared to the sham, periocular warming increased the distal skin temperature and distal-proximal skin temperature gradient only during the 30-min thermal manipulation period. In the subsequent sleep period, periocular warming facilitated sleep onset, increased stage 2 sleep and electroencephalographic delta activity during the first half of the sleep period relative to the sham. These results suggest that periocular skin warming may accelerate and deepen sleep by enhancing physiological heat loss via the distal skin, mimicking physiological conditions preceding habitual sleep.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":" ","pages":"20325"},"PeriodicalIF":4.3000,"publicationDate":"2020-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1038/s41598-020-77192-x","citationCount":"5","resultStr":"{\"title\":\"Periocular skin warming promotes body heat loss and sleep onset: a randomized placebo-controlled study.\",\"authors\":\"Tomohisa Ichiba, Masahiro Suzuki, Sayaka Aritake-Okada, Makoto Uchiyama\",\"doi\":\"10.1038/s41598-020-77192-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Periocular skin warming was reported to have favorable effects on subjective and objective sleep quality. We hypothesized that enhancing body heat loss by periocular skin warming would reduce sleep onset and improve sleep quality. Eighteen healthy volunteers were asked to maintain wakefulness with their eyes closed for 60 min after applying either a warming or sham eye mask, followed by a 60-min sleep period. Compared to the sham, periocular warming increased the distal skin temperature and distal-proximal skin temperature gradient only during the 30-min thermal manipulation period. In the subsequent sleep period, periocular warming facilitated sleep onset, increased stage 2 sleep and electroencephalographic delta activity during the first half of the sleep period relative to the sham. These results suggest that periocular skin warming may accelerate and deepen sleep by enhancing physiological heat loss via the distal skin, mimicking physiological conditions preceding habitual sleep.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":\" \",\"pages\":\"20325\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2020-11-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1038/s41598-020-77192-x\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"103\",\"ListUrlMain\":\"https://doi.org/10.1038/s41598-020-77192-x\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.1038/s41598-020-77192-x","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Periocular skin warming promotes body heat loss and sleep onset: a randomized placebo-controlled study.
Periocular skin warming was reported to have favorable effects on subjective and objective sleep quality. We hypothesized that enhancing body heat loss by periocular skin warming would reduce sleep onset and improve sleep quality. Eighteen healthy volunteers were asked to maintain wakefulness with their eyes closed for 60 min after applying either a warming or sham eye mask, followed by a 60-min sleep period. Compared to the sham, periocular warming increased the distal skin temperature and distal-proximal skin temperature gradient only during the 30-min thermal manipulation period. In the subsequent sleep period, periocular warming facilitated sleep onset, increased stage 2 sleep and electroencephalographic delta activity during the first half of the sleep period relative to the sham. These results suggest that periocular skin warming may accelerate and deepen sleep by enhancing physiological heat loss via the distal skin, mimicking physiological conditions preceding habitual sleep.
期刊介绍:
ACS Applied Electronic Materials is an interdisciplinary journal publishing original research covering all aspects of electronic materials. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials science, engineering, optics, physics, and chemistry into important applications of electronic materials. Sample research topics that span the journal's scope are inorganic, organic, ionic and polymeric materials with properties that include conducting, semiconducting, superconducting, insulating, dielectric, magnetic, optoelectronic, piezoelectric, ferroelectric and thermoelectric.
Indexed/Abstracted:
Web of Science SCIE
Scopus
CAS
INSPEC
Portico