{"title":"用MPC算法设计双激素血糖治疗方案并与单激素比较","authors":"Cifha Crecil Dias, Surekha Kamath, Sudha Vidyasagar","doi":"10.1049/iet-syb.2020.0053","DOIUrl":null,"url":null,"abstract":"<div>\n <p>The complete automated control and delivery of insulin and glucagon in type 1 diabetes is the developing technology for artificial pancreas. This improves the quality of life of a diabetic patient with the precise infusion. The amount of infusion of these hormones is controlled using a control algorithm, which has the prediction property. The control algorithm model predictive control (MPC) predicts one step ahead and infuses the hormones continuously according to the necessity for the regulation of blood glucose. In this research, the authors propose a MPC control algorithm, which is novel for a dual hormone infusion, for a mathematical model such as Sorenson model, and compare it with the insulin alone or single hormone infusion developed with MPC. Since they aim for complete automatic control and regulation, unmeasured disturbances at a random time are integrated and the performance evaluation is projected through statistical analysis. The blood glucose risk index (BGRI) and control variability grid analysis (CVGA) plot gives the additional evaluation for the comparative results of the two controllers claiming 88% performance by dual hormone evaluated through CVGA plot and 2.05 mg/dl average tracking error, 2.20 BGRI. The MPC developed for dual hormone significantly performs better and the time spent in normal glycaemia is longer while eliminating the risk of hyperglycaemia and hypoglycaemia.</p>\n </div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2020-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8687303/pdf/SYB2-14-241.pdf","citationCount":"1","resultStr":"{\"title\":\"Design of dual hormone blood glucose therapy and comparison with single hormone using MPC algorithm\",\"authors\":\"Cifha Crecil Dias, Surekha Kamath, Sudha Vidyasagar\",\"doi\":\"10.1049/iet-syb.2020.0053\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n <p>The complete automated control and delivery of insulin and glucagon in type 1 diabetes is the developing technology for artificial pancreas. This improves the quality of life of a diabetic patient with the precise infusion. The amount of infusion of these hormones is controlled using a control algorithm, which has the prediction property. The control algorithm model predictive control (MPC) predicts one step ahead and infuses the hormones continuously according to the necessity for the regulation of blood glucose. In this research, the authors propose a MPC control algorithm, which is novel for a dual hormone infusion, for a mathematical model such as Sorenson model, and compare it with the insulin alone or single hormone infusion developed with MPC. Since they aim for complete automatic control and regulation, unmeasured disturbances at a random time are integrated and the performance evaluation is projected through statistical analysis. The blood glucose risk index (BGRI) and control variability grid analysis (CVGA) plot gives the additional evaluation for the comparative results of the two controllers claiming 88% performance by dual hormone evaluated through CVGA plot and 2.05 mg/dl average tracking error, 2.20 BGRI. The MPC developed for dual hormone significantly performs better and the time spent in normal glycaemia is longer while eliminating the risk of hyperglycaemia and hypoglycaemia.</p>\\n </div>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2020-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8687303/pdf/SYB2-14-241.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/iet-syb.2020.0053\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"99","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/iet-syb.2020.0053","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Design of dual hormone blood glucose therapy and comparison with single hormone using MPC algorithm
The complete automated control and delivery of insulin and glucagon in type 1 diabetes is the developing technology for artificial pancreas. This improves the quality of life of a diabetic patient with the precise infusion. The amount of infusion of these hormones is controlled using a control algorithm, which has the prediction property. The control algorithm model predictive control (MPC) predicts one step ahead and infuses the hormones continuously according to the necessity for the regulation of blood glucose. In this research, the authors propose a MPC control algorithm, which is novel for a dual hormone infusion, for a mathematical model such as Sorenson model, and compare it with the insulin alone or single hormone infusion developed with MPC. Since they aim for complete automatic control and regulation, unmeasured disturbances at a random time are integrated and the performance evaluation is projected through statistical analysis. The blood glucose risk index (BGRI) and control variability grid analysis (CVGA) plot gives the additional evaluation for the comparative results of the two controllers claiming 88% performance by dual hormone evaluated through CVGA plot and 2.05 mg/dl average tracking error, 2.20 BGRI. The MPC developed for dual hormone significantly performs better and the time spent in normal glycaemia is longer while eliminating the risk of hyperglycaemia and hypoglycaemia.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.