唾液中SARS-CoV-2的鉴定和IgA抗体:一样两检诊断方法

Ada Aita, Daniela Basso, Anna Maria Cattelan, Paola Fioretto, Filippo Navaglia, Francesco Barbaro, Alice Stoppa, Enrico Coccorullo, Assunta Farella, Aurora Socal, Roberto Vettor, Mario Plebani
{"title":"唾液中SARS-CoV-2的鉴定和IgA抗体:一样两检诊断方法","authors":"Ada Aita,&nbsp;Daniela Basso,&nbsp;Anna Maria Cattelan,&nbsp;Paola Fioretto,&nbsp;Filippo Navaglia,&nbsp;Francesco Barbaro,&nbsp;Alice Stoppa,&nbsp;Enrico Coccorullo,&nbsp;Assunta Farella,&nbsp;Aurora Socal,&nbsp;Roberto Vettor,&nbsp;Mario Plebani","doi":"10.1016/j.cca.2020.09.018","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This study aims to verify whether standardized saliva collection is suitable for SARS-CoV-2 molecular detection and IgA measurement.</p><p><strong>Methods: </strong>43 COVID-19 inpatients and 326 screening subjects underwent naso-pharyngeal (NP)-swab and saliva collection (Salivette). Inpatients also underwent repeated blood collections to evaluate inflammation and organs involvement. In all patients and subjects, SARS-CoV-2 (gene E) rRT-PCR was undertaken in saliva and NP-swabs. Salivary IgA and serum IgA, IgG, IgM were measured on inpatients' samples.</p><p><strong>Results: </strong>NP-swabs and saliva were both SARS-CoV-2 positive in 7 (16%) or both negative in 35 (82%) out of 43 patients successfully included in the study. NP-swabs and saliva results did not perfectly match in one patient (saliva positive, NP-swab negative). Positive molecular results were significantly associated with disease duration (p = 0.0049). 326/326 screening subjects were SARS-CoV-2 negative on both NP-swabs and saliva. Among the 27 saliva samples tested for IgA, 18 were IgA positive. Salivary IgA positivity was associated with pneumonia (p = 0.002) and CRP values (p = 0.0183), not with other clinical and molecular data, or with serum immunoglubulins.</p><p><strong>Conclusions: </strong>A standardized saliva collection can be adopted to detect SARS-CoV-2 infection in alternative to NP-swabs. Preliminary data on salivary IgA support the use of saliva also for patient monitoring.</p>","PeriodicalId":504940,"journal":{"name":"Clinica chimica acta; international journal of clinical chemistry","volume":" ","pages":"717-722"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.cca.2020.09.018","citationCount":"56","resultStr":"{\"title\":\"SARS-CoV-2 identification and IgA antibodies in saliva: One sample two tests approach for diagnosis.\",\"authors\":\"Ada Aita,&nbsp;Daniela Basso,&nbsp;Anna Maria Cattelan,&nbsp;Paola Fioretto,&nbsp;Filippo Navaglia,&nbsp;Francesco Barbaro,&nbsp;Alice Stoppa,&nbsp;Enrico Coccorullo,&nbsp;Assunta Farella,&nbsp;Aurora Socal,&nbsp;Roberto Vettor,&nbsp;Mario Plebani\",\"doi\":\"10.1016/j.cca.2020.09.018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>This study aims to verify whether standardized saliva collection is suitable for SARS-CoV-2 molecular detection and IgA measurement.</p><p><strong>Methods: </strong>43 COVID-19 inpatients and 326 screening subjects underwent naso-pharyngeal (NP)-swab and saliva collection (Salivette). Inpatients also underwent repeated blood collections to evaluate inflammation and organs involvement. In all patients and subjects, SARS-CoV-2 (gene E) rRT-PCR was undertaken in saliva and NP-swabs. Salivary IgA and serum IgA, IgG, IgM were measured on inpatients' samples.</p><p><strong>Results: </strong>NP-swabs and saliva were both SARS-CoV-2 positive in 7 (16%) or both negative in 35 (82%) out of 43 patients successfully included in the study. NP-swabs and saliva results did not perfectly match in one patient (saliva positive, NP-swab negative). Positive molecular results were significantly associated with disease duration (p = 0.0049). 326/326 screening subjects were SARS-CoV-2 negative on both NP-swabs and saliva. Among the 27 saliva samples tested for IgA, 18 were IgA positive. Salivary IgA positivity was associated with pneumonia (p = 0.002) and CRP values (p = 0.0183), not with other clinical and molecular data, or with serum immunoglubulins.</p><p><strong>Conclusions: </strong>A standardized saliva collection can be adopted to detect SARS-CoV-2 infection in alternative to NP-swabs. Preliminary data on salivary IgA support the use of saliva also for patient monitoring.</p>\",\"PeriodicalId\":504940,\"journal\":{\"name\":\"Clinica chimica acta; international journal of clinical chemistry\",\"volume\":\" \",\"pages\":\"717-722\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.cca.2020.09.018\",\"citationCount\":\"56\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinica chimica acta; international journal of clinical chemistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.cca.2020.09.018\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/9/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinica chimica acta; international journal of clinical chemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.cca.2020.09.018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/9/16 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 56

摘要

目的:验证标准化唾液采集是否适用于SARS-CoV-2分子检测和IgA测定。方法:对43例新冠肺炎住院患者和326例筛查对象进行鼻咽拭子(NP)和唾液采集(Salivette)。住院患者还接受了反复采血,以评估炎症和器官受累情况。在所有患者和受试者中,对唾液和np拭子进行SARS-CoV-2(基因E) rRT-PCR检测。检测住院患者唾液IgA及血清IgA、IgG、IgM水平。结果:在43例成功纳入研究的患者中,np -拭子和唾液均为SARS-CoV-2阳性的有7例(16%),阴性的有35例(82%)。一名患者的np -拭子和唾液结果不完全吻合(唾液阳性,np -拭子阴性)。阳性分子结果与病程显著相关(p = 0.0049)。326/326筛查对象np拭子和唾液均为SARS-CoV-2阴性。在27份唾液样本中,IgA阳性18份。唾液IgA阳性与肺炎(p = 0.002)和CRP值(p = 0.0183)相关,与其他临床和分子数据或血清免疫球蛋白无关。结论:标准化唾液采集可替代np拭子检测SARS-CoV-2感染。唾液IgA的初步数据也支持将唾液用于患者监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

SARS-CoV-2 identification and IgA antibodies in saliva: One sample two tests approach for diagnosis.

SARS-CoV-2 identification and IgA antibodies in saliva: One sample two tests approach for diagnosis.

SARS-CoV-2 identification and IgA antibodies in saliva: One sample two tests approach for diagnosis.

Aim: This study aims to verify whether standardized saliva collection is suitable for SARS-CoV-2 molecular detection and IgA measurement.

Methods: 43 COVID-19 inpatients and 326 screening subjects underwent naso-pharyngeal (NP)-swab and saliva collection (Salivette). Inpatients also underwent repeated blood collections to evaluate inflammation and organs involvement. In all patients and subjects, SARS-CoV-2 (gene E) rRT-PCR was undertaken in saliva and NP-swabs. Salivary IgA and serum IgA, IgG, IgM were measured on inpatients' samples.

Results: NP-swabs and saliva were both SARS-CoV-2 positive in 7 (16%) or both negative in 35 (82%) out of 43 patients successfully included in the study. NP-swabs and saliva results did not perfectly match in one patient (saliva positive, NP-swab negative). Positive molecular results were significantly associated with disease duration (p = 0.0049). 326/326 screening subjects were SARS-CoV-2 negative on both NP-swabs and saliva. Among the 27 saliva samples tested for IgA, 18 were IgA positive. Salivary IgA positivity was associated with pneumonia (p = 0.002) and CRP values (p = 0.0183), not with other clinical and molecular data, or with serum immunoglubulins.

Conclusions: A standardized saliva collection can be adopted to detect SARS-CoV-2 infection in alternative to NP-swabs. Preliminary data on salivary IgA support the use of saliva also for patient monitoring.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信