Ioannis Politikos , Eric Davis , Melissa Nhaissi , John E. Wagner , Claudio G. Brunstein , Sandra Cohen , Elizabeth J. Shpall , Filippo Milano , Andromachi Scaradavou , Juliet N. Barker , American Society for Transplantation and Cellular Therapy Cord Blood Special Interest Group
{"title":"脐带血单位选择指南","authors":"Ioannis Politikos , Eric Davis , Melissa Nhaissi , John E. Wagner , Claudio G. Brunstein , Sandra Cohen , Elizabeth J. Shpall , Filippo Milano , Andromachi Scaradavou , Juliet N. Barker , American Society for Transplantation and Cellular Therapy Cord Blood Special Interest Group","doi":"10.1016/j.bbmt.2020.07.030","DOIUrl":null,"url":null,"abstract":"<div><p>Optimal cord blood (CB) unit selection is critical to maximize the likelihood of successful engraftment and survival after CB transplantation (CBT). However, unit selection can be complex because multiple characteristics must be considered including unit cell dose, donor-recipient human leukocyte antigen (HLA) match, and unit quality. This review provides evidence-based and experience-based comprehensive guidelines for CB unit selection. Topics addressed include the use of both the TNC and the CD34<sup>+</sup> cell dose, as well as the CD34<sup>+</sup> cell to TNC content ratio to evaluate unit progenitor cell content and engraftment potential, the acceptable TNC and CD34<sup>+</sup> cell dose criteria that define an adequate single-unit graft, and the indication and acceptable cell dose criteria for double-unit grafts. The acceptable criteria for 6-loci (HLA-A, -B antigen, -DRB1 allele) and 8-allele (HLA-A, -B, -C, -DRB1) donor-recipient HLA match, the evaluation of patients with donor-specific HLA antibodies, and the multiple determinants of unit quality are also reviewed in detail. Finally, a practical step-by-step guide to CB searches and the principles that guide ultimate graft selection are outlined.</p></div>","PeriodicalId":9165,"journal":{"name":"Biology of Blood and Marrow Transplantation","volume":"26 12","pages":"Pages 2190-2196"},"PeriodicalIF":4.3000,"publicationDate":"2020-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.bbmt.2020.07.030","citationCount":"38","resultStr":"{\"title\":\"Guidelines for Cord Blood Unit Selection\",\"authors\":\"Ioannis Politikos , Eric Davis , Melissa Nhaissi , John E. Wagner , Claudio G. Brunstein , Sandra Cohen , Elizabeth J. Shpall , Filippo Milano , Andromachi Scaradavou , Juliet N. Barker , American Society for Transplantation and Cellular Therapy Cord Blood Special Interest Group\",\"doi\":\"10.1016/j.bbmt.2020.07.030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Optimal cord blood (CB) unit selection is critical to maximize the likelihood of successful engraftment and survival after CB transplantation (CBT). However, unit selection can be complex because multiple characteristics must be considered including unit cell dose, donor-recipient human leukocyte antigen (HLA) match, and unit quality. This review provides evidence-based and experience-based comprehensive guidelines for CB unit selection. Topics addressed include the use of both the TNC and the CD34<sup>+</sup> cell dose, as well as the CD34<sup>+</sup> cell to TNC content ratio to evaluate unit progenitor cell content and engraftment potential, the acceptable TNC and CD34<sup>+</sup> cell dose criteria that define an adequate single-unit graft, and the indication and acceptable cell dose criteria for double-unit grafts. The acceptable criteria for 6-loci (HLA-A, -B antigen, -DRB1 allele) and 8-allele (HLA-A, -B, -C, -DRB1) donor-recipient HLA match, the evaluation of patients with donor-specific HLA antibodies, and the multiple determinants of unit quality are also reviewed in detail. Finally, a practical step-by-step guide to CB searches and the principles that guide ultimate graft selection are outlined.</p></div>\",\"PeriodicalId\":9165,\"journal\":{\"name\":\"Biology of Blood and Marrow Transplantation\",\"volume\":\"26 12\",\"pages\":\"Pages 2190-2196\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2020-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.bbmt.2020.07.030\",\"citationCount\":\"38\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biology of Blood and Marrow Transplantation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1083879120304560\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biology of Blood and Marrow Transplantation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1083879120304560","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
Optimal cord blood (CB) unit selection is critical to maximize the likelihood of successful engraftment and survival after CB transplantation (CBT). However, unit selection can be complex because multiple characteristics must be considered including unit cell dose, donor-recipient human leukocyte antigen (HLA) match, and unit quality. This review provides evidence-based and experience-based comprehensive guidelines for CB unit selection. Topics addressed include the use of both the TNC and the CD34+ cell dose, as well as the CD34+ cell to TNC content ratio to evaluate unit progenitor cell content and engraftment potential, the acceptable TNC and CD34+ cell dose criteria that define an adequate single-unit graft, and the indication and acceptable cell dose criteria for double-unit grafts. The acceptable criteria for 6-loci (HLA-A, -B antigen, -DRB1 allele) and 8-allele (HLA-A, -B, -C, -DRB1) donor-recipient HLA match, the evaluation of patients with donor-specific HLA antibodies, and the multiple determinants of unit quality are also reviewed in detail. Finally, a practical step-by-step guide to CB searches and the principles that guide ultimate graft selection are outlined.
期刊介绍:
Biology of Blood and Marrow Transplantation publishes original research reports, reviews, editorials, commentaries, letters to the editor, and hypotheses and is the official publication of the American Society for Transplantation and Cellular Therapy.
The journal focuses on current technology and knowledge in the interdisciplinary field of hematopoetic stem cell transplantation.