使用加湿器消毒剂对室内空气中5-氯-2-甲基异噻唑-3(2H)- 1 / 2-甲基异噻唑-3(2H)- 1 (CMIT/MIT)浓度的测定

Environmental analysis, health and toxicology Pub Date : 2020-06-01 Epub Date: 2020-06-30 DOI:10.5620/eaht.e2020008
Seon-Kyung Park, Hwi-Soo Seol, Hee-Jin Park, Yoon-Seob Kim, Seung-Hun Ryu, Jaehoon Kim, Suejin Kim, Jong-Hyeon Lee, Jung-Hwan Kwon
{"title":"使用加湿器消毒剂对室内空气中5-氯-2-甲基异噻唑-3(2H)- 1 / 2-甲基异噻唑-3(2H)- 1 (CMIT/MIT)浓度的测定","authors":"Seon-Kyung Park,&nbsp;Hwi-Soo Seol,&nbsp;Hee-Jin Park,&nbsp;Yoon-Seob Kim,&nbsp;Seung-Hun Ryu,&nbsp;Jaehoon Kim,&nbsp;Suejin Kim,&nbsp;Jong-Hyeon Lee,&nbsp;Jung-Hwan Kwon","doi":"10.5620/eaht.e2020008","DOIUrl":null,"url":null,"abstract":"<p><p>A mixture of 5-chloro-2-methylisothiazol-3(2H)-one/2-methylisothiazol-3(2H)-one (CMIT/MIT) had been used as an active ingredient in humidifier disinfectants (HDs). Owing to its high reactivity, the atmospheric concentration of CMIT/MIT, following its use in HD, would be lower than expected assuming that it is removed by ventilation only. In order to evaluate the exposure concentration of CMIT/MIT used as an HD, room-scale chamber studies were conducted under plausible use of three different HD doses at air change rates (ACR) of 0.3, 0.5, and 1.0 h-1. Atmospheric CMIT/MIT was sampled using two serial impingers containing deionized water after the attainment of steady state. Water samples in which CMIT/MIT was dissolved were concentrated using a cosolvent evaporation method with efficiencies of 35.5 and 77.9% for CMIT and MIT, respectively. The estimated air concentration, assuming that all the CMIT/MIT is absorbed in deionized water, increased linearly with increasing emission rate, but was independent of the ACR. This indicates that the removal rate of CMIT/MIT via chemical reactions is more than the removal rate by ventilation. Further investigations on homogeneous and heterogeneous chemical reactions of CMIT/MIT under ambient conditions are necessary to understand the actual exposure concentration of the mixture in HD.</p>","PeriodicalId":11867,"journal":{"name":"Environmental analysis, health and toxicology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/1d/e2/eaht-35-2-e2020008.PMC7374189.pdf","citationCount":"11","resultStr":"{\"title\":\"Experimental determination of indoor air concentration of 5-chloro-2-methylisothiazol-3(2H)-one/ 2-methylisothiazol-3(2H)-one (CMIT/MIT) emitted by the use of humidifier disinfectant.\",\"authors\":\"Seon-Kyung Park,&nbsp;Hwi-Soo Seol,&nbsp;Hee-Jin Park,&nbsp;Yoon-Seob Kim,&nbsp;Seung-Hun Ryu,&nbsp;Jaehoon Kim,&nbsp;Suejin Kim,&nbsp;Jong-Hyeon Lee,&nbsp;Jung-Hwan Kwon\",\"doi\":\"10.5620/eaht.e2020008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A mixture of 5-chloro-2-methylisothiazol-3(2H)-one/2-methylisothiazol-3(2H)-one (CMIT/MIT) had been used as an active ingredient in humidifier disinfectants (HDs). Owing to its high reactivity, the atmospheric concentration of CMIT/MIT, following its use in HD, would be lower than expected assuming that it is removed by ventilation only. In order to evaluate the exposure concentration of CMIT/MIT used as an HD, room-scale chamber studies were conducted under plausible use of three different HD doses at air change rates (ACR) of 0.3, 0.5, and 1.0 h-1. Atmospheric CMIT/MIT was sampled using two serial impingers containing deionized water after the attainment of steady state. Water samples in which CMIT/MIT was dissolved were concentrated using a cosolvent evaporation method with efficiencies of 35.5 and 77.9% for CMIT and MIT, respectively. The estimated air concentration, assuming that all the CMIT/MIT is absorbed in deionized water, increased linearly with increasing emission rate, but was independent of the ACR. This indicates that the removal rate of CMIT/MIT via chemical reactions is more than the removal rate by ventilation. Further investigations on homogeneous and heterogeneous chemical reactions of CMIT/MIT under ambient conditions are necessary to understand the actual exposure concentration of the mixture in HD.</p>\",\"PeriodicalId\":11867,\"journal\":{\"name\":\"Environmental analysis, health and toxicology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/1d/e2/eaht-35-2-e2020008.PMC7374189.pdf\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental analysis, health and toxicology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5620/eaht.e2020008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/6/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental analysis, health and toxicology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5620/eaht.e2020008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/6/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

用5-氯-2-甲基异噻唑-3(2H)- 1 /2-甲基异噻唑-3(2H)- 1 (CMIT/MIT)混合物作为加湿器消毒剂(hd)的有效成分。由于其高反应性,CMIT/MIT在HD中使用后,假设仅通过通风去除,其大气浓度将低于预期。为了评估CMIT/MIT作为HD的暴露浓度,在空气变化速率(ACR)为0.3、0.5和1.0 h-1的情况下,进行了三种不同HD剂量的室内研究。在达到稳态后,使用两个含去离子水的连续撞击器对大气CMIT/MIT进行采样。采用共溶剂蒸发法对溶解CMIT/MIT的水样进行浓缩,CMIT和MIT的效率分别为35.5%和77.9%。假设所有的CMIT/MIT都被去离子水吸收,估计的空气浓度随排放率的增加而线性增加,但与ACR无关。这说明化学反应对CMIT/MIT的去除率大于通风的去除率。进一步研究环境条件下CMIT/MIT的均相和非均相化学反应是了解混合物在HD中的实际暴露浓度的必要条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Experimental determination of indoor air concentration of 5-chloro-2-methylisothiazol-3(2H)-one/ 2-methylisothiazol-3(2H)-one (CMIT/MIT) emitted by the use of humidifier disinfectant.

Experimental determination of indoor air concentration of 5-chloro-2-methylisothiazol-3(2H)-one/ 2-methylisothiazol-3(2H)-one (CMIT/MIT) emitted by the use of humidifier disinfectant.

A mixture of 5-chloro-2-methylisothiazol-3(2H)-one/2-methylisothiazol-3(2H)-one (CMIT/MIT) had been used as an active ingredient in humidifier disinfectants (HDs). Owing to its high reactivity, the atmospheric concentration of CMIT/MIT, following its use in HD, would be lower than expected assuming that it is removed by ventilation only. In order to evaluate the exposure concentration of CMIT/MIT used as an HD, room-scale chamber studies were conducted under plausible use of three different HD doses at air change rates (ACR) of 0.3, 0.5, and 1.0 h-1. Atmospheric CMIT/MIT was sampled using two serial impingers containing deionized water after the attainment of steady state. Water samples in which CMIT/MIT was dissolved were concentrated using a cosolvent evaporation method with efficiencies of 35.5 and 77.9% for CMIT and MIT, respectively. The estimated air concentration, assuming that all the CMIT/MIT is absorbed in deionized water, increased linearly with increasing emission rate, but was independent of the ACR. This indicates that the removal rate of CMIT/MIT via chemical reactions is more than the removal rate by ventilation. Further investigations on homogeneous and heterogeneous chemical reactions of CMIT/MIT under ambient conditions are necessary to understand the actual exposure concentration of the mixture in HD.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信