{"title":"经皮房间隔缺损装置关闭对儿童心脏电重构的近期和短期影响","authors":"Alaa Mahmoud Roushdy, Hebatalla Attia, Heba Nossir","doi":"10.1016/j.ehj.2018.02.005","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>The beneficial effects of atrial septal defect (ASD) device closure on electrical cardiac remodeling are well established. The timing at which these effects starts to take place has yet to be determined.</p></div><div><h3>Objectives</h3><p>To determine the immediate and short term effects of ASD device closure on cardiac electric remodeling in children.</p></div><div><h3>Methods</h3><p>30 pediatric patients were subjected to 12 lead Electrocardiogram immediately before ASD device closure, 24 h post procedure, 1 and 6 months after. The maximum and minimum P wave and QT durations in any of the 12 leads were recorded and P wave and QT dispersions were calculated and compared using paired <em>T</em> test.</p></div><div><h3>Results</h3><p>The immediate 24 h follow up electrocardiogram showed significant decrease in P maximum (140.2 ± 6 versus 130.67 ± 5.4 ms), P dispersion (49.73 ± 9.01 versus 41.43 ± 7.65 ms), PR interval (188.7 ± 6.06 ms versus 182.73 ± 5.8 ms), QRS duration (134.4 ± 4.97 ms versus 127.87 ± 4.44), QT maximum (619.07 ± 15.73 ms versus 613.43 ± 11.87), and QT dispersion (67.6 ± 5.31 versus 62.6 ± 4.68 ms) (P = 0.001). After 1 month all the parameters measured showed further significant decrease with P dispersion reaching 32.13 ± 6 (P = 0.001) and QT dispersion reaching 55.0 ± 4.76 (P = 0.001). These effects were maintained 6 months post device closure.</p></div><div><h3>Conclusion</h3><p>Percutaneous ASD device closure can reverse electrical changes in atrial and ventricular myocardium as early as the first 24 h post device closure.</p></div>","PeriodicalId":44962,"journal":{"name":"Egyptian Heart Journal","volume":"70 4","pages":"Pages 243-247"},"PeriodicalIF":1.4000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.ehj.2018.02.005","citationCount":"5","resultStr":"{\"title\":\"Immediate and short term effects of percutaneous atrial septal defect device closure on cardiac electrical remodeling in children\",\"authors\":\"Alaa Mahmoud Roushdy, Hebatalla Attia, Heba Nossir\",\"doi\":\"10.1016/j.ehj.2018.02.005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>The beneficial effects of atrial septal defect (ASD) device closure on electrical cardiac remodeling are well established. The timing at which these effects starts to take place has yet to be determined.</p></div><div><h3>Objectives</h3><p>To determine the immediate and short term effects of ASD device closure on cardiac electric remodeling in children.</p></div><div><h3>Methods</h3><p>30 pediatric patients were subjected to 12 lead Electrocardiogram immediately before ASD device closure, 24 h post procedure, 1 and 6 months after. The maximum and minimum P wave and QT durations in any of the 12 leads were recorded and P wave and QT dispersions were calculated and compared using paired <em>T</em> test.</p></div><div><h3>Results</h3><p>The immediate 24 h follow up electrocardiogram showed significant decrease in P maximum (140.2 ± 6 versus 130.67 ± 5.4 ms), P dispersion (49.73 ± 9.01 versus 41.43 ± 7.65 ms), PR interval (188.7 ± 6.06 ms versus 182.73 ± 5.8 ms), QRS duration (134.4 ± 4.97 ms versus 127.87 ± 4.44), QT maximum (619.07 ± 15.73 ms versus 613.43 ± 11.87), and QT dispersion (67.6 ± 5.31 versus 62.6 ± 4.68 ms) (P = 0.001). After 1 month all the parameters measured showed further significant decrease with P dispersion reaching 32.13 ± 6 (P = 0.001) and QT dispersion reaching 55.0 ± 4.76 (P = 0.001). These effects were maintained 6 months post device closure.</p></div><div><h3>Conclusion</h3><p>Percutaneous ASD device closure can reverse electrical changes in atrial and ventricular myocardium as early as the first 24 h post device closure.</p></div>\",\"PeriodicalId\":44962,\"journal\":{\"name\":\"Egyptian Heart Journal\",\"volume\":\"70 4\",\"pages\":\"Pages 243-247\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.ehj.2018.02.005\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Egyptian Heart Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1110260817301849\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Heart Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1110260817301849","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Immediate and short term effects of percutaneous atrial septal defect device closure on cardiac electrical remodeling in children
Background
The beneficial effects of atrial septal defect (ASD) device closure on electrical cardiac remodeling are well established. The timing at which these effects starts to take place has yet to be determined.
Objectives
To determine the immediate and short term effects of ASD device closure on cardiac electric remodeling in children.
Methods
30 pediatric patients were subjected to 12 lead Electrocardiogram immediately before ASD device closure, 24 h post procedure, 1 and 6 months after. The maximum and minimum P wave and QT durations in any of the 12 leads were recorded and P wave and QT dispersions were calculated and compared using paired T test.
Results
The immediate 24 h follow up electrocardiogram showed significant decrease in P maximum (140.2 ± 6 versus 130.67 ± 5.4 ms), P dispersion (49.73 ± 9.01 versus 41.43 ± 7.65 ms), PR interval (188.7 ± 6.06 ms versus 182.73 ± 5.8 ms), QRS duration (134.4 ± 4.97 ms versus 127.87 ± 4.44), QT maximum (619.07 ± 15.73 ms versus 613.43 ± 11.87), and QT dispersion (67.6 ± 5.31 versus 62.6 ± 4.68 ms) (P = 0.001). After 1 month all the parameters measured showed further significant decrease with P dispersion reaching 32.13 ± 6 (P = 0.001) and QT dispersion reaching 55.0 ± 4.76 (P = 0.001). These effects were maintained 6 months post device closure.
Conclusion
Percutaneous ASD device closure can reverse electrical changes in atrial and ventricular myocardium as early as the first 24 h post device closure.
期刊介绍:
The Egyptian Heart Journal is the official journal of the Egyptian Society of Cardiology. It is an international journal that publishes peer-reviewed articles on all aspects of cardiovascular disease, including original clinical studies and translational investigations. The journal publishes research, review articles, case reports and commentary articles, as well as editorials interpreting and commenting on the research presented. In addition, it provides a forum for the exchange of information on all aspects of cardiovascular medicine, including educational issues.