经皮从肺动脉取出栓塞的孕酮避孕植入物。

IF 1.8 Q3 OBSTETRICS & GYNECOLOGY
Open access journal of contraception Pub Date : 2018-07-17 eCollection Date: 2018-01-01 DOI:10.2147/OAJC.S165827
Mohammed Majid Akhtar, Amit Bhan, Zhan Yun Lim, Mohammed Abid Akhtar, Neha Sekhri, Preeti Bharadwaj, Michael Mullen
{"title":"经皮从肺动脉取出栓塞的孕酮避孕植入物。","authors":"Mohammed Majid Akhtar,&nbsp;Amit Bhan,&nbsp;Zhan Yun Lim,&nbsp;Mohammed Abid Akhtar,&nbsp;Neha Sekhri,&nbsp;Preeti Bharadwaj,&nbsp;Michael Mullen","doi":"10.2147/OAJC.S165827","DOIUrl":null,"url":null,"abstract":"<p><p>The Nexplanon<sup>®</sup> implant is a commonly used radiopaque contraceptive device that contains progestogen associated with an ethylene vinyl-acetate copolymer resulting in a slow release of the active hormonal ingredient. It is inserted into the subdermal connective tissue and provides contraceptive efficacy for up to 3 years. Device removal for clinical, personal or device \"end-of-life span\" reasons is straightforward. In rare cases, implant migration can occur locally within centimeters of the insertion site. Distant device embolization is extremely rare and can result in complications including chest pain, dyspnoea, pneumothorax and thrombosis or prevent conception until the active ingredient is depleted. We present one such case, where a Nexplanon<sup>®</sup> implant embolized into the pulmonary artery of a young female patient. We describe the initial \"missed\" diagnosis of embolized device on a chest radiograph and subsequent successful percutaneous removal once distant embolization was diagnosed.</p>","PeriodicalId":74348,"journal":{"name":"Open access journal of contraception","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2018-07-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2147/OAJC.S165827","citationCount":"6","resultStr":"{\"title\":\"Percutaneous extraction of an embolized progesterone contraceptive implant from the pulmonary artery.\",\"authors\":\"Mohammed Majid Akhtar,&nbsp;Amit Bhan,&nbsp;Zhan Yun Lim,&nbsp;Mohammed Abid Akhtar,&nbsp;Neha Sekhri,&nbsp;Preeti Bharadwaj,&nbsp;Michael Mullen\",\"doi\":\"10.2147/OAJC.S165827\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The Nexplanon<sup>®</sup> implant is a commonly used radiopaque contraceptive device that contains progestogen associated with an ethylene vinyl-acetate copolymer resulting in a slow release of the active hormonal ingredient. It is inserted into the subdermal connective tissue and provides contraceptive efficacy for up to 3 years. Device removal for clinical, personal or device \\\"end-of-life span\\\" reasons is straightforward. In rare cases, implant migration can occur locally within centimeters of the insertion site. Distant device embolization is extremely rare and can result in complications including chest pain, dyspnoea, pneumothorax and thrombosis or prevent conception until the active ingredient is depleted. We present one such case, where a Nexplanon<sup>®</sup> implant embolized into the pulmonary artery of a young female patient. We describe the initial \\\"missed\\\" diagnosis of embolized device on a chest radiograph and subsequent successful percutaneous removal once distant embolization was diagnosed.</p>\",\"PeriodicalId\":74348,\"journal\":{\"name\":\"Open access journal of contraception\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2018-07-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.2147/OAJC.S165827\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open access journal of contraception\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/OAJC.S165827\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open access journal of contraception","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OAJC.S165827","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 6

摘要

Nexplanon®植入物是一种常用的不透射线避孕装置,含有孕激素与乙烯乙烯-醋酸酯共聚物,导致活性激素成分缓慢释放。它被插入皮下结缔组织,提供长达3年的避孕效果。出于临床、个人或设备“寿命结束”的原因而移除设备是直截了当的。在极少数情况下,植入物迁移可发生在植入部位几厘米内的局部。远端器械栓塞极为罕见,可能导致并发症,包括胸痛、呼吸困难、气胸和血栓形成,或阻止受孕,直到有效成分耗尽。我们提出一个这样的案例,其中一个Nexplanon®植入物栓塞到肺动脉的年轻女性患者。我们描述了最初的“错过”诊断的栓塞装置胸片和随后的成功经皮切除一旦远处栓塞的诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Percutaneous extraction of an embolized progesterone contraceptive implant from the pulmonary artery.

Percutaneous extraction of an embolized progesterone contraceptive implant from the pulmonary artery.

The Nexplanon® implant is a commonly used radiopaque contraceptive device that contains progestogen associated with an ethylene vinyl-acetate copolymer resulting in a slow release of the active hormonal ingredient. It is inserted into the subdermal connective tissue and provides contraceptive efficacy for up to 3 years. Device removal for clinical, personal or device "end-of-life span" reasons is straightforward. In rare cases, implant migration can occur locally within centimeters of the insertion site. Distant device embolization is extremely rare and can result in complications including chest pain, dyspnoea, pneumothorax and thrombosis or prevent conception until the active ingredient is depleted. We present one such case, where a Nexplanon® implant embolized into the pulmonary artery of a young female patient. We describe the initial "missed" diagnosis of embolized device on a chest radiograph and subsequent successful percutaneous removal once distant embolization was diagnosed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信