{"title":"核箍设计对铸造桩核修复牙抗断裂性能的影响。","authors":"Loubna Shamseddine, Farid Chaaban","doi":"10.1155/2016/5073459","DOIUrl":null,"url":null,"abstract":"<p><p>Objectives. To investigate the influence of a contra bevel on the fracture resistance of teeth restored with cast post and core. Materials and Methods. Sixty plastic analogues of an upper incisor were endodontically treated and prepared with 6° internal taper and 2 mm of ferrule in order to receive a cast post and core. The prepared samples were divided into two groups (n = 30); the first group serves as control while the second group was prepared with an external 30° bevel on the buccal and lingual walls. All samples crowned were exposed to a compressive load at 130° to their long axis until fractures occurred. Fracture resistance loads were recorded and failure modes were also observed. Mann-Whitney test was carried out to compare the two groups. Results. Mean failure loads for the groups were, respectively, 1038.69 N (SD ±243.52 N) and 1078.89 N (SD ±352.21 N). Statistically, there was no significant difference between the two groups (P = 0.7675 > 0.05). Conclusion. In the presence of a ferrule and a crown in the anterior teeth, adding a secondary ferrule to the cast post and core will not increase the resistance to fracture. </p>","PeriodicalId":53309,"journal":{"name":"Advances in Medicine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2016/5073459","citationCount":"6","resultStr":"{\"title\":\"Impact of a Core Ferrule Design on Fracture Resistance of Teeth Restored with Cast Post and Core.\",\"authors\":\"Loubna Shamseddine, Farid Chaaban\",\"doi\":\"10.1155/2016/5073459\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Objectives. To investigate the influence of a contra bevel on the fracture resistance of teeth restored with cast post and core. Materials and Methods. Sixty plastic analogues of an upper incisor were endodontically treated and prepared with 6° internal taper and 2 mm of ferrule in order to receive a cast post and core. The prepared samples were divided into two groups (n = 30); the first group serves as control while the second group was prepared with an external 30° bevel on the buccal and lingual walls. All samples crowned were exposed to a compressive load at 130° to their long axis until fractures occurred. Fracture resistance loads were recorded and failure modes were also observed. Mann-Whitney test was carried out to compare the two groups. Results. Mean failure loads for the groups were, respectively, 1038.69 N (SD ±243.52 N) and 1078.89 N (SD ±352.21 N). Statistically, there was no significant difference between the two groups (P = 0.7675 > 0.05). Conclusion. In the presence of a ferrule and a crown in the anterior teeth, adding a secondary ferrule to the cast post and core will not increase the resistance to fracture. </p>\",\"PeriodicalId\":53309,\"journal\":{\"name\":\"Advances in Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2016/5073459\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2016/5073459\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2016/6/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2016/5073459","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/6/22 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
摘要
目标。目的:探讨反斜角对铸造桩核修复牙抗折性的影响。材料与方法。采用6°内锥度和2mm卡箍对60个塑料模拟上切牙进行根管处理,以获得铸造桩和核。将制备好的样品分为两组(n = 30);第一组作为对照,第二组在颊和舌壁上准备一个30°的外斜面。所有被加冕的样品都暴露在与长轴130°的压缩载荷下,直到发生断裂。记录了断裂阻力载荷,并观察了破坏模式。采用曼-惠特尼检验对两组进行比较。结果。各组的平均失效载荷分别为1038.69 N (SD±243.52 N)和1078.89 N (SD±352.21 N)。两组间差异无统计学意义(P = 0.7675 > 0.05)。结论。在前牙有卡箍和牙冠的情况下,在铸造桩核上增加二次卡箍不会增加抗折断的能力。
Impact of a Core Ferrule Design on Fracture Resistance of Teeth Restored with Cast Post and Core.
Objectives. To investigate the influence of a contra bevel on the fracture resistance of teeth restored with cast post and core. Materials and Methods. Sixty plastic analogues of an upper incisor were endodontically treated and prepared with 6° internal taper and 2 mm of ferrule in order to receive a cast post and core. The prepared samples were divided into two groups (n = 30); the first group serves as control while the second group was prepared with an external 30° bevel on the buccal and lingual walls. All samples crowned were exposed to a compressive load at 130° to their long axis until fractures occurred. Fracture resistance loads were recorded and failure modes were also observed. Mann-Whitney test was carried out to compare the two groups. Results. Mean failure loads for the groups were, respectively, 1038.69 N (SD ±243.52 N) and 1078.89 N (SD ±352.21 N). Statistically, there was no significant difference between the two groups (P = 0.7675 > 0.05). Conclusion. In the presence of a ferrule and a crown in the anterior teeth, adding a secondary ferrule to the cast post and core will not increase the resistance to fracture.