独立振荡式中央血压监测仪的实际适用性:对Microlife WatchBP办公室中心的回顾。

IF 3.8 Q1 PERIPHERAL VASCULAR DISEASE
Pulse Pub Date : 2016-04-01 Epub Date: 2016-02-12 DOI:10.1159/000443771
Willem J Verberk, Hao-Min Cheng, Li-Chih Huang, Chia-Ming Lin, Yao-Pin Teng, Chen-Huan Chen
{"title":"独立振荡式中央血压监测仪的实际适用性:对Microlife WatchBP办公室中心的回顾。","authors":"Willem J Verberk,&nbsp;Hao-Min Cheng,&nbsp;Li-Chih Huang,&nbsp;Chia-Ming Lin,&nbsp;Yao-Pin Teng,&nbsp;Chen-Huan Chen","doi":"10.1159/000443771","DOIUrl":null,"url":null,"abstract":"<p><p>Accumulating evidence indicates that central blood pressure (CBP) is a better cardiovascular risk predictor than brachial blood pressure (BP). Although more additional benefits of CBP-based treatment above usual hypertension treatment are to be demonstrated, the demand for implementing CBP assessment in general clinical practice is increasing. For this, the measurement procedure must be noninvasive, easy to perform, and cost- and time-efficient. Therefore, oscillometric devices with the possibility to assess CBP seem the best option. Recently, such an oscillometric BP monitor, the Microlife WatchBP Office Central, was developed, which demonstrated its high accuracy in a validation study against invasive BP measurement. Calibration errors of this device are limited because the procedure is automated, standardized, and performed at the same place of and within 30 s from pulse wave assessment. The transformation from the peripheral pulse wave to CBP is done by means of an individual-based pulse wave analysis according to a theory of arterial compliance and wave reflections. In addition, the device has demonstrated to enable a more reliable diagnosis of hypertension by CBP than by peripheral BP, with a lower frequency of over- and underdiagnosis. Altogether, the available clinical evidence suggests that the Microlife WatchBP Office Central fulfills the criteria for general clinical use. </p>","PeriodicalId":29774,"journal":{"name":"Pulse","volume":"3 3-4","pages":"205-16"},"PeriodicalIF":3.8000,"publicationDate":"2016-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000443771","citationCount":"7","resultStr":"{\"title\":\"Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central.\",\"authors\":\"Willem J Verberk,&nbsp;Hao-Min Cheng,&nbsp;Li-Chih Huang,&nbsp;Chia-Ming Lin,&nbsp;Yao-Pin Teng,&nbsp;Chen-Huan Chen\",\"doi\":\"10.1159/000443771\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Accumulating evidence indicates that central blood pressure (CBP) is a better cardiovascular risk predictor than brachial blood pressure (BP). Although more additional benefits of CBP-based treatment above usual hypertension treatment are to be demonstrated, the demand for implementing CBP assessment in general clinical practice is increasing. For this, the measurement procedure must be noninvasive, easy to perform, and cost- and time-efficient. Therefore, oscillometric devices with the possibility to assess CBP seem the best option. Recently, such an oscillometric BP monitor, the Microlife WatchBP Office Central, was developed, which demonstrated its high accuracy in a validation study against invasive BP measurement. Calibration errors of this device are limited because the procedure is automated, standardized, and performed at the same place of and within 30 s from pulse wave assessment. The transformation from the peripheral pulse wave to CBP is done by means of an individual-based pulse wave analysis according to a theory of arterial compliance and wave reflections. In addition, the device has demonstrated to enable a more reliable diagnosis of hypertension by CBP than by peripheral BP, with a lower frequency of over- and underdiagnosis. Altogether, the available clinical evidence suggests that the Microlife WatchBP Office Central fulfills the criteria for general clinical use. </p>\",\"PeriodicalId\":29774,\"journal\":{\"name\":\"Pulse\",\"volume\":\"3 3-4\",\"pages\":\"205-16\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2016-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000443771\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pulse\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000443771\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2016/2/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pulse","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000443771","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/2/12 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 7

摘要

越来越多的证据表明,中枢血压(CBP)是比肱血压(BP)更好的心血管风险预测指标。尽管基于CBP的治疗比常规高血压治疗有更多的额外益处,但在一般临床实践中实施CBP评估的需求正在增加。为此,测量过程必须是非侵入性的,易于执行,成本和时间效率高。因此,有可能评估CBP的振荡装置似乎是最好的选择。最近,一种名为Microlife WatchBP Office Central的振荡式血压监测仪被开发出来,并在一项针对侵入性血压测量的验证研究中证明了它的高准确性。该设备的校准误差是有限的,因为该过程是自动化的,标准化的,并且在脉冲波评估的同一地点和30秒内进行。根据动脉顺应性和波反射理论,通过基于个体的脉搏波分析来完成从外周脉搏波到CBP的转换。此外,该设备已被证明能够通过CBP比外周BP更可靠地诊断高血压,并且诊断过度和诊断不足的频率更低。总之,现有的临床证据表明,Microlife WatchBP Office Central符合一般临床使用的标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central.

Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central.

Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central.

Accumulating evidence indicates that central blood pressure (CBP) is a better cardiovascular risk predictor than brachial blood pressure (BP). Although more additional benefits of CBP-based treatment above usual hypertension treatment are to be demonstrated, the demand for implementing CBP assessment in general clinical practice is increasing. For this, the measurement procedure must be noninvasive, easy to perform, and cost- and time-efficient. Therefore, oscillometric devices with the possibility to assess CBP seem the best option. Recently, such an oscillometric BP monitor, the Microlife WatchBP Office Central, was developed, which demonstrated its high accuracy in a validation study against invasive BP measurement. Calibration errors of this device are limited because the procedure is automated, standardized, and performed at the same place of and within 30 s from pulse wave assessment. The transformation from the peripheral pulse wave to CBP is done by means of an individual-based pulse wave analysis according to a theory of arterial compliance and wave reflections. In addition, the device has demonstrated to enable a more reliable diagnosis of hypertension by CBP than by peripheral BP, with a lower frequency of over- and underdiagnosis. Altogether, the available clinical evidence suggests that the Microlife WatchBP Office Central fulfills the criteria for general clinical use.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
4.50%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信