{"title":"样品储存温度和时间延迟对人体动脉血样品血气、碳酸氢盐和pH值的影响。","authors":"Elham Mohammadhoseini, Enayat Safavi, Sepideh Seifi, Soroush Seifirad, Shahram Firoozbakhsh, Soheil Peiman","doi":"10.5812/ircmj.13577","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type.</p><p><strong>Objectives: </strong>To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples.</p><p><strong>Patients and methods: </strong>2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling.</p><p><strong>Results: </strong>PaO2 of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO2 of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P < 0.001). In samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes.</p><p><strong>Conclusions: </strong>In samples stored in plastic syringes, overestimation of PaO2 levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour.</p>","PeriodicalId":14628,"journal":{"name":"Iranian Red Crescent Medical Journal","volume":" ","pages":"e13577"},"PeriodicalIF":0.4000,"publicationDate":"2015-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5812/ircmj.13577","citationCount":"20","resultStr":"{\"title\":\"Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples.\",\"authors\":\"Elham Mohammadhoseini, Enayat Safavi, Sepideh Seifi, Soroush Seifirad, Shahram Firoozbakhsh, Soheil Peiman\",\"doi\":\"10.5812/ircmj.13577\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type.</p><p><strong>Objectives: </strong>To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples.</p><p><strong>Patients and methods: </strong>2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling.</p><p><strong>Results: </strong>PaO2 of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO2 of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P < 0.001). In samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes.</p><p><strong>Conclusions: </strong>In samples stored in plastic syringes, overestimation of PaO2 levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour.</p>\",\"PeriodicalId\":14628,\"journal\":{\"name\":\"Iranian Red Crescent Medical Journal\",\"volume\":\" \",\"pages\":\"e13577\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2015-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.5812/ircmj.13577\",\"citationCount\":\"20\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Red Crescent Medical Journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5812/ircmj.13577\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2015/3/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Red Crescent Medical Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5812/ircmj.13577","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2015/3/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20
摘要
背景:动脉血气分析结果可能受到分析前因素的影响,如分析前的时间间隔、储存温度和注射器类型。目的:探讨样品保存温度和时间延迟对人动脉血样品血气、碳酸氢盐和PH值的影响。患者和方法:45例患者经动脉内留置导管取动脉血样2.5 mL。每个样本分成5个等量样本,保存在多用途结核菌素塑料注射器中。尽快对五个样本中的一个进行血气分析。另外4份样品分为两组,分别保存在22°C和0°C。在采样后30和60分钟重复血气分析。结果:0℃保存60 min后,样品PaO2明显升高(P = 0.007)。在22℃下保存30min和60min的PaCO2显著高于初步结果(P = 0.04, P < 0.001)。在22°C保存的样品中,pH在30和60分钟后显著下降(P = 0.017, P = 0.001)。样品在0°C或22°C保存30或60分钟后的其他结果无显著差异。结论:在塑料注射器中保存的样品中,如果样品在分析前冷却,应注意PaO2水平的高估。在储存在塑料注射器中的样品中,当分析延迟长达一小时时,不需要将样品储存在冰水中。
Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples.
Background: Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type.
Objectives: To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples.
Patients and methods: 2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling.
Results: PaO2 of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO2 of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P < 0.001). In samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes.
Conclusions: In samples stored in plastic syringes, overestimation of PaO2 levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour.
期刊介绍:
The IRANIAN RED CRESCENT MEDICAL JOURNAL is an international, English language, peer-reviewed journal dealing with general Medicine and Surgery, Disaster Medicine and Health Policy. It is an official Journal of the Iranian Hospital Dubai and is published monthly. The Iranian Red Crescent Medical Journal aims at publishing the high quality materials, both clinical and scientific, on all aspects of Medicine and Surgery