{"title":"在卟啉症诊断和监测中使用的分析技术的区域差异:一个协调的案例?","authors":"Christiaan W Sies,&nbsp;Virginia Cronin,&nbsp;Christopher M Florkowski,&nbsp;Jan Gill,&nbsp;Janine Grant,&nbsp;Victor Poulos,&nbsp;John Zoanetti","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Royal College of Pathologists of Australasia (RCPA) Porphyrin Quality Assurance Program assesses the measurement of urine, faecal, plasma and whole blood porphyrins and their components plus urinary porphobilinogen and delta aminolaevulinic acid and has laboratories enrolled from around the world. It was observed that there was a wide scatter in results submitted to some subsections of the program.</p><p><strong>Methods: </strong>A detailed questionnaire covering the analytical techniques used in the diagnosis of porphyria was sent to all laboratories enrolled in the RCPA Porphyrin Quality Assurance Program. Additionally, self-enrolment data over a five year period was examined for trends/changes in standardisation, reagent sources and analytical technique.</p><p><strong>Results: </strong>Twenty of the 45 laboratories enrolled in the Porphyrin Quality Assurance Program completed the survey, providing a snapshot of the analytical techniques used world-wide. Post survey self enrolment data indicated only little or no noticeable changes to analytical standardisation of techniques despite the continual lack of agreement of results in subsections of the External Quality Assurance program.</p><p><strong>Conclusions: </strong>While some aspects of porphyria testing are relatively consistent between laboratories, other diagnostic techniques vary widely. A wide variety of individualised reference intervals and reporting techniques is currently in use world-wide. While most of the participants in the survey are regional reference centres specialising in the diagnosis of porphyria and, as such, their diagnostic capability is not in question, international guidelines or global harmonisation of analytical techniques should allow better inter-laboratory comparisons to be made, ultimately improving diagnostic accuracy.</p>","PeriodicalId":34924,"journal":{"name":"Clinical Biochemist Reviews","volume":"36 2","pages":"63-74"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4504156/pdf/cbr-36-63.pdf","citationCount":"0","resultStr":"{\"title\":\"Regional Variation in Analytical Techniques used in the Diagnosis and Monitoring of Porphyria: a Case for Harmonisation?\",\"authors\":\"Christiaan W Sies,&nbsp;Virginia Cronin,&nbsp;Christopher M Florkowski,&nbsp;Jan Gill,&nbsp;Janine Grant,&nbsp;Victor Poulos,&nbsp;John Zoanetti\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The Royal College of Pathologists of Australasia (RCPA) Porphyrin Quality Assurance Program assesses the measurement of urine, faecal, plasma and whole blood porphyrins and their components plus urinary porphobilinogen and delta aminolaevulinic acid and has laboratories enrolled from around the world. It was observed that there was a wide scatter in results submitted to some subsections of the program.</p><p><strong>Methods: </strong>A detailed questionnaire covering the analytical techniques used in the diagnosis of porphyria was sent to all laboratories enrolled in the RCPA Porphyrin Quality Assurance Program. Additionally, self-enrolment data over a five year period was examined for trends/changes in standardisation, reagent sources and analytical technique.</p><p><strong>Results: </strong>Twenty of the 45 laboratories enrolled in the Porphyrin Quality Assurance Program completed the survey, providing a snapshot of the analytical techniques used world-wide. Post survey self enrolment data indicated only little or no noticeable changes to analytical standardisation of techniques despite the continual lack of agreement of results in subsections of the External Quality Assurance program.</p><p><strong>Conclusions: </strong>While some aspects of porphyria testing are relatively consistent between laboratories, other diagnostic techniques vary widely. A wide variety of individualised reference intervals and reporting techniques is currently in use world-wide. While most of the participants in the survey are regional reference centres specialising in the diagnosis of porphyria and, as such, their diagnostic capability is not in question, international guidelines or global harmonisation of analytical techniques should allow better inter-laboratory comparisons to be made, ultimately improving diagnostic accuracy.</p>\",\"PeriodicalId\":34924,\"journal\":{\"name\":\"Clinical Biochemist Reviews\",\"volume\":\"36 2\",\"pages\":\"63-74\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4504156/pdf/cbr-36-63.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Biochemist Reviews\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Biochemistry, Genetics and Molecular Biology\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Biochemist Reviews","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

摘要

背景:澳大利亚皇家病理学院(RCPA)卟啉质量保证计划评估尿液、粪便、血浆和全血卟啉及其成分以及尿卟胆色素原和氨基乙酰丙酸的测量,并有来自世界各地的实验室注册。据观察,在提交给该计划的某些子部分的结果中存在广泛的分散。方法:向参加RCPA卟啉质量保证计划的所有实验室发送一份详细的调查问卷,其中包括卟啉症诊断中使用的分析技术。此外,还审查了五年期间的自我登记数据,以了解标准化、试剂来源和分析技术的趋势/变化。结果:参加卟啉质量保证计划的45个实验室中有20个完成了调查,提供了世界范围内使用的分析技术的快照。调查后的自我登记数据表明,尽管在外部质量保证计划的子部分中持续缺乏一致的结果,但分析技术的标准化只有很少或没有明显的变化。结论:虽然卟啉症检测的某些方面在实验室之间相对一致,但其他诊断技术差异很大。各种各样的个性化参考间隔和报告技术目前在世界范围内使用。虽然调查的大多数参与者都是专门从事卟啉症诊断的区域参考中心,因此,他们的诊断能力不存在问题,但国际指南或全球分析技术的统一应该允许更好的实验室间比较,最终提高诊断准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Regional Variation in Analytical Techniques used in the Diagnosis and Monitoring of Porphyria: a Case for Harmonisation?

Regional Variation in Analytical Techniques used in the Diagnosis and Monitoring of Porphyria: a Case for Harmonisation?

Background: The Royal College of Pathologists of Australasia (RCPA) Porphyrin Quality Assurance Program assesses the measurement of urine, faecal, plasma and whole blood porphyrins and their components plus urinary porphobilinogen and delta aminolaevulinic acid and has laboratories enrolled from around the world. It was observed that there was a wide scatter in results submitted to some subsections of the program.

Methods: A detailed questionnaire covering the analytical techniques used in the diagnosis of porphyria was sent to all laboratories enrolled in the RCPA Porphyrin Quality Assurance Program. Additionally, self-enrolment data over a five year period was examined for trends/changes in standardisation, reagent sources and analytical technique.

Results: Twenty of the 45 laboratories enrolled in the Porphyrin Quality Assurance Program completed the survey, providing a snapshot of the analytical techniques used world-wide. Post survey self enrolment data indicated only little or no noticeable changes to analytical standardisation of techniques despite the continual lack of agreement of results in subsections of the External Quality Assurance program.

Conclusions: While some aspects of porphyria testing are relatively consistent between laboratories, other diagnostic techniques vary widely. A wide variety of individualised reference intervals and reporting techniques is currently in use world-wide. While most of the participants in the survey are regional reference centres specialising in the diagnosis of porphyria and, as such, their diagnostic capability is not in question, international guidelines or global harmonisation of analytical techniques should allow better inter-laboratory comparisons to be made, ultimately improving diagnostic accuracy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Biochemist Reviews
Clinical Biochemist Reviews Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信