Daniel Kümin, Monika Gsell Albert, Benjamin Weber, Kathrin Summermatter
{"title":"过氧化氢熏蒸搭便车指南,第 2 部分:核实和验证过氧化氢熏蒸循环。","authors":"Daniel Kümin, Monika Gsell Albert, Benjamin Weber, Kathrin Summermatter","doi":"10.1089/apb.21.921099","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Part 1 of this two-part series describes the use of hydrogen peroxide as a fumigant and compares it with other fumigants on the market. Technical requirements are outlined while considering physical and biological limitations of the system. This second part focuses primarily on the use of process controls to verify and validate hydrogen peroxide fumigations. Finally, a model encompassing the entire fumigation process is presented. <b>Methods:</b> Part 2 of the series focuses on the authors' long-time personal experiences in room and filter fumigation using various fumigation systems and is supplemented with relevant literature searches. <b>Results:</b> The reader is introduced to the planning and implementation of fumigation process validations. Biological indicators help users develop safe and efficient processes. Chemical indicators can be used as process controls, while measuring physical parameters will help avoid condensation of hydrogen peroxide. How many biological and chemical indicators and what type should be applied for cycle development are additionally explained. <b>Discussion:</b> It is important to consider numerous technical requirements when planning to implement hydrogen peroxide fumigation at an institution. Also, considerable thought needs to go into the verification and validation of the fumigation process. <b>Conclusions:</b> Part 1 of this series presents an overview of different fumigation systems based on hydrogen peroxide on the market and their technical requirements. Part 2 focuses on validation and verification of hydrogen peroxide fumigation while considering the entire fumigation process. The two parts together will serve users as a guide to establishing hydrogen peroxide fumigations at their facilities.</p>","PeriodicalId":7962,"journal":{"name":"Applied Biosafety","volume":"26 1","pages":"42-51"},"PeriodicalIF":0.5000,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8869643/pdf/apb.21.921099.pdf","citationCount":"0","resultStr":"{\"title\":\"The Hitchhiker's Guide to Hydrogen Peroxide Fumigation, Part 2: Verifying and Validating Hydrogen Peroxide Fumigation Cycles.\",\"authors\":\"Daniel Kümin, Monika Gsell Albert, Benjamin Weber, Kathrin Summermatter\",\"doi\":\"10.1089/apb.21.921099\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Introduction:</b> Part 1 of this two-part series describes the use of hydrogen peroxide as a fumigant and compares it with other fumigants on the market. Technical requirements are outlined while considering physical and biological limitations of the system. This second part focuses primarily on the use of process controls to verify and validate hydrogen peroxide fumigations. Finally, a model encompassing the entire fumigation process is presented. <b>Methods:</b> Part 2 of the series focuses on the authors' long-time personal experiences in room and filter fumigation using various fumigation systems and is supplemented with relevant literature searches. <b>Results:</b> The reader is introduced to the planning and implementation of fumigation process validations. Biological indicators help users develop safe and efficient processes. Chemical indicators can be used as process controls, while measuring physical parameters will help avoid condensation of hydrogen peroxide. How many biological and chemical indicators and what type should be applied for cycle development are additionally explained. <b>Discussion:</b> It is important to consider numerous technical requirements when planning to implement hydrogen peroxide fumigation at an institution. Also, considerable thought needs to go into the verification and validation of the fumigation process. <b>Conclusions:</b> Part 1 of this series presents an overview of different fumigation systems based on hydrogen peroxide on the market and their technical requirements. Part 2 focuses on validation and verification of hydrogen peroxide fumigation while considering the entire fumigation process. The two parts together will serve users as a guide to establishing hydrogen peroxide fumigations at their facilities.</p>\",\"PeriodicalId\":7962,\"journal\":{\"name\":\"Applied Biosafety\",\"volume\":\"26 1\",\"pages\":\"42-51\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2021-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8869643/pdf/apb.21.921099.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Biosafety\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1089/apb.21.921099\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/3/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Biosafety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/apb.21.921099","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/3/19 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
The Hitchhiker's Guide to Hydrogen Peroxide Fumigation, Part 2: Verifying and Validating Hydrogen Peroxide Fumigation Cycles.
Introduction: Part 1 of this two-part series describes the use of hydrogen peroxide as a fumigant and compares it with other fumigants on the market. Technical requirements are outlined while considering physical and biological limitations of the system. This second part focuses primarily on the use of process controls to verify and validate hydrogen peroxide fumigations. Finally, a model encompassing the entire fumigation process is presented. Methods: Part 2 of the series focuses on the authors' long-time personal experiences in room and filter fumigation using various fumigation systems and is supplemented with relevant literature searches. Results: The reader is introduced to the planning and implementation of fumigation process validations. Biological indicators help users develop safe and efficient processes. Chemical indicators can be used as process controls, while measuring physical parameters will help avoid condensation of hydrogen peroxide. How many biological and chemical indicators and what type should be applied for cycle development are additionally explained. Discussion: It is important to consider numerous technical requirements when planning to implement hydrogen peroxide fumigation at an institution. Also, considerable thought needs to go into the verification and validation of the fumigation process. Conclusions: Part 1 of this series presents an overview of different fumigation systems based on hydrogen peroxide on the market and their technical requirements. Part 2 focuses on validation and verification of hydrogen peroxide fumigation while considering the entire fumigation process. The two parts together will serve users as a guide to establishing hydrogen peroxide fumigations at their facilities.
Applied BiosafetyEnvironmental Science-Management, Monitoring, Policy and Law
CiteScore
2.50
自引率
13.30%
发文量
27
期刊介绍:
Applied Biosafety (APB), sponsored by ABSA International, is a peer-reviewed, scientific journal committed to promoting global biosafety awareness and best practices to prevent occupational exposures and adverse environmental impacts related to biohazardous releases. APB provides a forum for exchanging sound biosafety and biosecurity initiatives by publishing original articles, review articles, letters to the editors, commentaries, and brief reviews. APB informs scientists, safety professionals, policymakers, engineers, architects, and governmental organizations. The journal is committed to publishing on topics significant in well-resourced countries as well as information relevant to underserved regions, engaging and cultivating the development of biosafety professionals globally.