生物摩擦学的基本原理及其在脊柱关节置换术中的应用

Megan L. Harper MASc , Andrew Dooris PhD , Philippe E. Paré MASc
{"title":"生物摩擦学的基本原理及其在脊柱关节置换术中的应用","authors":"Megan L. Harper MASc ,&nbsp;Andrew Dooris PhD ,&nbsp;Philippe E. Paré MASc","doi":"10.1016/j.esas.2009.11.004","DOIUrl":null,"url":null,"abstract":"<div><p>The biological effect of wear of articulating surfaces is a continued concern with large joint replacements and, likewise, of interest for total disc replacements. There are a number of important biotribological testing parameters that can greatly affect the outcome of a wear study in addition to the implant design and material selection. The current ASTM and ISO wear testing standards/guides for spine arthroplasty leave many choices as testing parameters. These factors include but are not limited to the sequence of kinematics and load, phasing, type of lubricant, and specimen preparation (sterilization and artificial aging). The spinal community should critically assess wear studies and be cognizant of the influence of the selected parameters on the test results.</p></div>","PeriodicalId":88695,"journal":{"name":"SAS journal","volume":"3 4","pages":"Pages 125-132"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.esas.2009.11.004","citationCount":"23","resultStr":"{\"title\":\"The fundamentals of biotribology and its application to spine arthroplasty\",\"authors\":\"Megan L. Harper MASc ,&nbsp;Andrew Dooris PhD ,&nbsp;Philippe E. Paré MASc\",\"doi\":\"10.1016/j.esas.2009.11.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The biological effect of wear of articulating surfaces is a continued concern with large joint replacements and, likewise, of interest for total disc replacements. There are a number of important biotribological testing parameters that can greatly affect the outcome of a wear study in addition to the implant design and material selection. The current ASTM and ISO wear testing standards/guides for spine arthroplasty leave many choices as testing parameters. These factors include but are not limited to the sequence of kinematics and load, phasing, type of lubricant, and specimen preparation (sterilization and artificial aging). The spinal community should critically assess wear studies and be cognizant of the influence of the selected parameters on the test results.</p></div>\",\"PeriodicalId\":88695,\"journal\":{\"name\":\"SAS journal\",\"volume\":\"3 4\",\"pages\":\"Pages 125-132\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.esas.2009.11.004\",\"citationCount\":\"23\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SAS journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1935981009000358\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SAS journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1935981009000358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

摘要

关节面磨损的生物学效应在大关节置换术中一直受到关注,同样,对全椎间盘置换术也很感兴趣。除了植入物的设计和材料的选择外,还有许多重要的生物摩擦学测试参数可以极大地影响磨损研究的结果。目前的ASTM和ISO脊柱关节置换术磨损测试标准/指南留下了许多选择作为测试参数。这些因素包括但不限于运动学和载荷顺序、相位、润滑剂类型和试样制备(灭菌和人工老化)。脊柱界应该严格评估磨损研究,并认识到所选参数对测试结果的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The fundamentals of biotribology and its application to spine arthroplasty

The fundamentals of biotribology and its application to spine arthroplasty

The fundamentals of biotribology and its application to spine arthroplasty

The biological effect of wear of articulating surfaces is a continued concern with large joint replacements and, likewise, of interest for total disc replacements. There are a number of important biotribological testing parameters that can greatly affect the outcome of a wear study in addition to the implant design and material selection. The current ASTM and ISO wear testing standards/guides for spine arthroplasty leave many choices as testing parameters. These factors include but are not limited to the sequence of kinematics and load, phasing, type of lubricant, and specimen preparation (sterilization and artificial aging). The spinal community should critically assess wear studies and be cognizant of the influence of the selected parameters on the test results.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信