Megan L. Harper MASc , Andrew Dooris PhD , Philippe E. Paré MASc
{"title":"生物摩擦学的基本原理及其在脊柱关节置换术中的应用","authors":"Megan L. Harper MASc , Andrew Dooris PhD , Philippe E. Paré MASc","doi":"10.1016/j.esas.2009.11.004","DOIUrl":null,"url":null,"abstract":"<div><p>The biological effect of wear of articulating surfaces is a continued concern with large joint replacements and, likewise, of interest for total disc replacements. There are a number of important biotribological testing parameters that can greatly affect the outcome of a wear study in addition to the implant design and material selection. The current ASTM and ISO wear testing standards/guides for spine arthroplasty leave many choices as testing parameters. These factors include but are not limited to the sequence of kinematics and load, phasing, type of lubricant, and specimen preparation (sterilization and artificial aging). The spinal community should critically assess wear studies and be cognizant of the influence of the selected parameters on the test results.</p></div>","PeriodicalId":88695,"journal":{"name":"SAS journal","volume":"3 4","pages":"Pages 125-132"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.esas.2009.11.004","citationCount":"23","resultStr":"{\"title\":\"The fundamentals of biotribology and its application to spine arthroplasty\",\"authors\":\"Megan L. Harper MASc , Andrew Dooris PhD , Philippe E. Paré MASc\",\"doi\":\"10.1016/j.esas.2009.11.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The biological effect of wear of articulating surfaces is a continued concern with large joint replacements and, likewise, of interest for total disc replacements. There are a number of important biotribological testing parameters that can greatly affect the outcome of a wear study in addition to the implant design and material selection. The current ASTM and ISO wear testing standards/guides for spine arthroplasty leave many choices as testing parameters. These factors include but are not limited to the sequence of kinematics and load, phasing, type of lubricant, and specimen preparation (sterilization and artificial aging). The spinal community should critically assess wear studies and be cognizant of the influence of the selected parameters on the test results.</p></div>\",\"PeriodicalId\":88695,\"journal\":{\"name\":\"SAS journal\",\"volume\":\"3 4\",\"pages\":\"Pages 125-132\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.esas.2009.11.004\",\"citationCount\":\"23\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SAS journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1935981009000358\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SAS journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1935981009000358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The fundamentals of biotribology and its application to spine arthroplasty
The biological effect of wear of articulating surfaces is a continued concern with large joint replacements and, likewise, of interest for total disc replacements. There are a number of important biotribological testing parameters that can greatly affect the outcome of a wear study in addition to the implant design and material selection. The current ASTM and ISO wear testing standards/guides for spine arthroplasty leave many choices as testing parameters. These factors include but are not limited to the sequence of kinematics and load, phasing, type of lubricant, and specimen preparation (sterilization and artificial aging). The spinal community should critically assess wear studies and be cognizant of the influence of the selected parameters on the test results.