前下颌舌孔:体内研究。

Anatomy research international Pub Date : 2014-01-01 Epub Date: 2014-08-25 DOI:10.1155/2014/906348
Sara Bernardi, Claudio Rastelli, Cinzia Leuter, Roberto Gatto, Maria Adelaide Continenza
{"title":"前下颌舌孔:体内研究。","authors":"Sara Bernardi,&nbsp;Claudio Rastelli,&nbsp;Cinzia Leuter,&nbsp;Roberto Gatto,&nbsp;Maria Adelaide Continenza","doi":"10.1155/2014/906348","DOIUrl":null,"url":null,"abstract":"<p><p>In descriptions of surgical procedures in mandible, often there is no mention of an anatomical variance, the genial spinal foramina, where nerves and vessels go through. Aim of this study is to investigate frequency, shape, and dimensions of these foramina. 56 computed tomography dentascans were analyzed with an implant planning software. The considered parameters were frequency, number, position, diameters, and length of canals; the collected data were inserted in a spreadsheet and statistically analyzed; therefore, they were compared with those found in the literature. The measurements agree with the ones found in earlier studies, except for the length of the inferior spinal canals, which resulted lesser than that found in the literature. The frequency of the inferior spinal foramina, the data related to the inferior spinal foramina diameter (cross scan), and the measurements related to the superior spinal foramina diameter (axial scan) resulted to be major compared to those reported in literature. These obtained results are clinically interesting because an implant planning software has been employed, daily used by operators, and that permits in vivo investigations. Furthermore, due to the possibility of hemorrhagic accidents in this mandibular region, these data are particularly interesting for all of the operators who make interventions in this area. </p>","PeriodicalId":89526,"journal":{"name":"Anatomy research international","volume":"2014 ","pages":"906348"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2014/906348","citationCount":"18","resultStr":"{\"title\":\"Anterior mandibular lingual foramina: an in vivo investigation.\",\"authors\":\"Sara Bernardi,&nbsp;Claudio Rastelli,&nbsp;Cinzia Leuter,&nbsp;Roberto Gatto,&nbsp;Maria Adelaide Continenza\",\"doi\":\"10.1155/2014/906348\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In descriptions of surgical procedures in mandible, often there is no mention of an anatomical variance, the genial spinal foramina, where nerves and vessels go through. Aim of this study is to investigate frequency, shape, and dimensions of these foramina. 56 computed tomography dentascans were analyzed with an implant planning software. The considered parameters were frequency, number, position, diameters, and length of canals; the collected data were inserted in a spreadsheet and statistically analyzed; therefore, they were compared with those found in the literature. The measurements agree with the ones found in earlier studies, except for the length of the inferior spinal canals, which resulted lesser than that found in the literature. The frequency of the inferior spinal foramina, the data related to the inferior spinal foramina diameter (cross scan), and the measurements related to the superior spinal foramina diameter (axial scan) resulted to be major compared to those reported in literature. These obtained results are clinically interesting because an implant planning software has been employed, daily used by operators, and that permits in vivo investigations. Furthermore, due to the possibility of hemorrhagic accidents in this mandibular region, these data are particularly interesting for all of the operators who make interventions in this area. </p>\",\"PeriodicalId\":89526,\"journal\":{\"name\":\"Anatomy research international\",\"volume\":\"2014 \",\"pages\":\"906348\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2014/906348\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Anatomy research international\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2014/906348\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2014/8/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anatomy research international","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2014/906348","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2014/8/25 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

在对下颌骨手术的描述中,通常没有提到解剖变异,即神经和血管经过的脊柱孔。本研究的目的是研究这些孔的频率、形状和尺寸。用种植计划软件对56张牙体ct扫描结果进行分析。考虑的参数有:根管的频率、数量、位置、直径和长度;将收集到的数据放入电子表格并进行统计分析;因此,将它们与文献中发现的结果进行比较。测量结果与早期研究中发现的结果一致,除了下椎管的长度,这比文献中发现的结果要小。与文献报道相比,下椎间孔的频率、与下椎间孔直径相关的数据(交叉扫描)和与上椎间孔直径相关的测量结果(轴向扫描)是主要的。这些获得的结果在临床上很有趣,因为植入计划软件已经被使用,操作者每天使用,并且允许体内研究。此外,由于下颌骨区域出血事故的可能性,这些数据对所有在该区域进行干预的手术者来说都特别有趣。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Anterior mandibular lingual foramina: an in vivo investigation.

Anterior mandibular lingual foramina: an in vivo investigation.

Anterior mandibular lingual foramina: an in vivo investigation.

Anterior mandibular lingual foramina: an in vivo investigation.

In descriptions of surgical procedures in mandible, often there is no mention of an anatomical variance, the genial spinal foramina, where nerves and vessels go through. Aim of this study is to investigate frequency, shape, and dimensions of these foramina. 56 computed tomography dentascans were analyzed with an implant planning software. The considered parameters were frequency, number, position, diameters, and length of canals; the collected data were inserted in a spreadsheet and statistically analyzed; therefore, they were compared with those found in the literature. The measurements agree with the ones found in earlier studies, except for the length of the inferior spinal canals, which resulted lesser than that found in the literature. The frequency of the inferior spinal foramina, the data related to the inferior spinal foramina diameter (cross scan), and the measurements related to the superior spinal foramina diameter (axial scan) resulted to be major compared to those reported in literature. These obtained results are clinically interesting because an implant planning software has been employed, daily used by operators, and that permits in vivo investigations. Furthermore, due to the possibility of hemorrhagic accidents in this mandibular region, these data are particularly interesting for all of the operators who make interventions in this area.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信