{"title":"基于免疫亲和分离循环肿瘤细胞的微流控装置的设计","authors":"Begum Sen-Dogan , Ender Yildirim , Sebnem Sahin , Ebru Ozgur , Ozge Zorlu , Haluk Kulah","doi":"10.1016/j.snr.2023.100169","DOIUrl":null,"url":null,"abstract":"<div><p>Combining bioaffinity-based techniques with microfluidics is an effective strategy for the selective isolation of rare circulating tumor cells (CTCs) among peripheral blood cells. In this scope, designing a microfluidic channel with high cell-surface interaction is crucial, which can be realized by increasing surface area <em>via</em> micropillars. In such microfluidic channels, the interpillar distance represents a critical design parameter, and the value is decided considering the trade-off between the possibility of clogging and CTC capture efficiency. In this study, a curvilinear microfluidic channel with a wide (150 µm) interpillar distance was developed to prevent clogging while maintaining high CTC capture efficiency. Computational fluid dynamics was used to compare the residence time of particles in the designed channels. For the proof-of-concept study, microfabricated channels were biofunctionalized for immunoaffinity-based isolation of CTCs, using anti-EpCAM antibodies. Enhanced CTC capture was enabled through the micropillars inside the channels helping the increased encounters between the cells and the antibody-functionalized surface. The curvilinear channel effectively isolated cells from MCF-7 breast cancer cell line among white blood cells, with more than 85% capture efficiency. The rate of non-specific binding of white blood cells remained below 20%. This study demonstrated the ability to increase the interactions between particles and surfaces without requiring a dense layout of the micropillars inside the microchannel, therefore minimizing the clogging possibility of the channel without sacrificing performance.</p></div>","PeriodicalId":426,"journal":{"name":"Sensors and Actuators Reports","volume":"6 ","pages":"Article 100169"},"PeriodicalIF":6.5000,"publicationDate":"2023-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of a microfluidic device for immunoaffinity-based isolation of circulating tumor cells with minimal clogging\",\"authors\":\"Begum Sen-Dogan , Ender Yildirim , Sebnem Sahin , Ebru Ozgur , Ozge Zorlu , Haluk Kulah\",\"doi\":\"10.1016/j.snr.2023.100169\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Combining bioaffinity-based techniques with microfluidics is an effective strategy for the selective isolation of rare circulating tumor cells (CTCs) among peripheral blood cells. In this scope, designing a microfluidic channel with high cell-surface interaction is crucial, which can be realized by increasing surface area <em>via</em> micropillars. In such microfluidic channels, the interpillar distance represents a critical design parameter, and the value is decided considering the trade-off between the possibility of clogging and CTC capture efficiency. In this study, a curvilinear microfluidic channel with a wide (150 µm) interpillar distance was developed to prevent clogging while maintaining high CTC capture efficiency. Computational fluid dynamics was used to compare the residence time of particles in the designed channels. For the proof-of-concept study, microfabricated channels were biofunctionalized for immunoaffinity-based isolation of CTCs, using anti-EpCAM antibodies. Enhanced CTC capture was enabled through the micropillars inside the channels helping the increased encounters between the cells and the antibody-functionalized surface. The curvilinear channel effectively isolated cells from MCF-7 breast cancer cell line among white blood cells, with more than 85% capture efficiency. The rate of non-specific binding of white blood cells remained below 20%. This study demonstrated the ability to increase the interactions between particles and surfaces without requiring a dense layout of the micropillars inside the microchannel, therefore minimizing the clogging possibility of the channel without sacrificing performance.</p></div>\",\"PeriodicalId\":426,\"journal\":{\"name\":\"Sensors and Actuators Reports\",\"volume\":\"6 \",\"pages\":\"Article 100169\"},\"PeriodicalIF\":6.5000,\"publicationDate\":\"2023-07-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensors and Actuators Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666053923000322\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensors and Actuators Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666053923000322","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
Design of a microfluidic device for immunoaffinity-based isolation of circulating tumor cells with minimal clogging
Combining bioaffinity-based techniques with microfluidics is an effective strategy for the selective isolation of rare circulating tumor cells (CTCs) among peripheral blood cells. In this scope, designing a microfluidic channel with high cell-surface interaction is crucial, which can be realized by increasing surface area via micropillars. In such microfluidic channels, the interpillar distance represents a critical design parameter, and the value is decided considering the trade-off between the possibility of clogging and CTC capture efficiency. In this study, a curvilinear microfluidic channel with a wide (150 µm) interpillar distance was developed to prevent clogging while maintaining high CTC capture efficiency. Computational fluid dynamics was used to compare the residence time of particles in the designed channels. For the proof-of-concept study, microfabricated channels were biofunctionalized for immunoaffinity-based isolation of CTCs, using anti-EpCAM antibodies. Enhanced CTC capture was enabled through the micropillars inside the channels helping the increased encounters between the cells and the antibody-functionalized surface. The curvilinear channel effectively isolated cells from MCF-7 breast cancer cell line among white blood cells, with more than 85% capture efficiency. The rate of non-specific binding of white blood cells remained below 20%. This study demonstrated the ability to increase the interactions between particles and surfaces without requiring a dense layout of the micropillars inside the microchannel, therefore minimizing the clogging possibility of the channel without sacrificing performance.
期刊介绍:
Sensors and Actuators Reports is a peer-reviewed open access journal launched out from the Sensors and Actuators journal family. Sensors and Actuators Reports is dedicated to publishing new and original works in the field of all type of sensors and actuators, including bio-, chemical-, physical-, and nano- sensors and actuators, which demonstrates significant progress beyond the current state of the art. The journal regularly publishes original research papers, reviews, and short communications.
For research papers and short communications, the journal aims to publish the new and original work supported by experimental results and as such purely theoretical works are not accepted.