Nan Wang, Liqin Zhu, Xuequn Zhao, Wenjie Yang, He Sun
{"title":"改进HPLC法测定莫西沙星在传染病患者药代动力学研究中的应用。","authors":"Nan Wang, Liqin Zhu, Xuequn Zhao, Wenjie Yang, He Sun","doi":"10.1155/2013/462918","DOIUrl":null,"url":null,"abstract":"<p><p>Objective. To develop a simple and rapid high-performance liquid chromatography (HPLC) method for measuring moxifloxacin concentration in human plasma. Methods. Following a single step liquid-liquid extraction, analytes along with an internal standard (IS) were separated using an isocratic mobile phase of 0.1% triethylamine (adjusted pH to 4.8 with phosphoric acid)/acetonitrile (80/20, v/v) at flow rate of 1 mL/min on reverse phase Kromasil C18 column (250 mm × 4.6 mm, 5 μ m) at room temperature. Results. Total analytical run time for selecting moxifloxacin was 15 min. The assays exhibited good linearity (r (2) = 0.9998) over the studied range of 25 to 5000 ng/mL. The absolute recovery rate of low, medium, and high concentrations were 69.88%, 78.86%, and 78.51%, respectively. The relative recovery rates were 98.50%, 96.61%, and 101.79%, respectively. Coefficient of variation and error at both of the intraday and interday assessments were less than 4.7%. Conclusions. The results indicated that this method is a simple, rapid, precise and accurate assay for the determination of moxifloxacin concentrations in human plasma. This validated method is sensitive and reproducible enough to be used in pharmacokinetic studies.</p>","PeriodicalId":14662,"journal":{"name":"ISRN Pharmacology","volume":"2013 ","pages":"462918"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2013/462918","citationCount":"12","resultStr":"{\"title\":\"Improved HPLC method for the determination of moxifloxacin in application to a pharmacokinetics study in patients with infectious diseases.\",\"authors\":\"Nan Wang, Liqin Zhu, Xuequn Zhao, Wenjie Yang, He Sun\",\"doi\":\"10.1155/2013/462918\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Objective. To develop a simple and rapid high-performance liquid chromatography (HPLC) method for measuring moxifloxacin concentration in human plasma. Methods. Following a single step liquid-liquid extraction, analytes along with an internal standard (IS) were separated using an isocratic mobile phase of 0.1% triethylamine (adjusted pH to 4.8 with phosphoric acid)/acetonitrile (80/20, v/v) at flow rate of 1 mL/min on reverse phase Kromasil C18 column (250 mm × 4.6 mm, 5 μ m) at room temperature. Results. Total analytical run time for selecting moxifloxacin was 15 min. The assays exhibited good linearity (r (2) = 0.9998) over the studied range of 25 to 5000 ng/mL. The absolute recovery rate of low, medium, and high concentrations were 69.88%, 78.86%, and 78.51%, respectively. The relative recovery rates were 98.50%, 96.61%, and 101.79%, respectively. Coefficient of variation and error at both of the intraday and interday assessments were less than 4.7%. Conclusions. The results indicated that this method is a simple, rapid, precise and accurate assay for the determination of moxifloxacin concentrations in human plasma. This validated method is sensitive and reproducible enough to be used in pharmacokinetic studies.</p>\",\"PeriodicalId\":14662,\"journal\":{\"name\":\"ISRN Pharmacology\",\"volume\":\"2013 \",\"pages\":\"462918\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-05-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2013/462918\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISRN Pharmacology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2013/462918\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2013/1/1 0:00:00\",\"PubModel\":\"Print\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN Pharmacology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2013/462918","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/1/1 0:00:00","PubModel":"Print","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12
摘要
目标。建立一种简便、快速的高效液相色谱法测定人血浆中莫西沙星浓度。方法。采用单步液-液萃取,内标物(IS)以0.1%三乙胺(用磷酸调节pH至4.8)/乙腈(80/20,v/v)为等温流动相,在反相Kromasil C18柱(250 mm × 4.6 mm, 5 μ m)上,流速为1 mL/min,室温下分离。结果。选择莫西沙星的总分析运行时间为15 min。在25 ~ 5000 ng/mL范围内线性良好(r(2) = 0.9998)。低、中、高浓度的绝对回收率分别为69.88%、78.86%、78.51%。相对回收率分别为98.50%、96.61%和101.79%。日内和日间评估的变异系数和误差均小于4.7%。结论。结果表明,该方法简便、快速、精密度高、准确度高,可用于人血浆中莫西沙星浓度的测定。该方法灵敏度高,重复性好,可用于药代动力学研究。
Improved HPLC method for the determination of moxifloxacin in application to a pharmacokinetics study in patients with infectious diseases.
Objective. To develop a simple and rapid high-performance liquid chromatography (HPLC) method for measuring moxifloxacin concentration in human plasma. Methods. Following a single step liquid-liquid extraction, analytes along with an internal standard (IS) were separated using an isocratic mobile phase of 0.1% triethylamine (adjusted pH to 4.8 with phosphoric acid)/acetonitrile (80/20, v/v) at flow rate of 1 mL/min on reverse phase Kromasil C18 column (250 mm × 4.6 mm, 5 μ m) at room temperature. Results. Total analytical run time for selecting moxifloxacin was 15 min. The assays exhibited good linearity (r (2) = 0.9998) over the studied range of 25 to 5000 ng/mL. The absolute recovery rate of low, medium, and high concentrations were 69.88%, 78.86%, and 78.51%, respectively. The relative recovery rates were 98.50%, 96.61%, and 101.79%, respectively. Coefficient of variation and error at both of the intraday and interday assessments were less than 4.7%. Conclusions. The results indicated that this method is a simple, rapid, precise and accurate assay for the determination of moxifloxacin concentrations in human plasma. This validated method is sensitive and reproducible enough to be used in pharmacokinetic studies.