{"title":"一种在不发达国家潜在应用的乙型肝炎抗体测定方法。","authors":"Sarah N Schumacher, Tim R Randolph","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The objective of this study was to develop a simple, cost-effective method of HbF determination potentially useable in underdeveloped countries to determine sickle cell patient response to hydroxyurea treatment. Normal adult blood (HbA), cord blood (HbF), and a 50:50 mixture (HbA+F) were the three sample types used in procedure development. Normal blood samples were collected from the research team, and de-identified cord blood samples were provided by Cardinal Glennon Pediatric Research Institute, St. Louis, MO. The hematocrit of all blood samples was standardized to 35%. The method, based on the Kleihauer-Betke (K-B) test principle, used a citrate solution to selectively elute HbA from RBCs while HbF remained intracellular, and spectrophotometric absorbance of the eluate was the primary outcome measure. A procedure was developed and optimized utilizing a 395 nm wavelength, 30 sec centrifugation time, 6 min incubation time, 20 microL blood volume, and 0.07 M sodium citrate in a 0.06 M sodium phosphate buffer solution. Reproducibility was demonstrated (N = 39) with a mean HbA absorbance of 1.285 (SD 0.069), mean HbA+F absorbance of 0.690 (SD 0.050), and mean HbF absorbance of 0.035 (SD 0.005), also exhibiting linearity (r2 = 0.99). This simple, cost-effective method of HbF determination shows potential as a basis for determining sickle cell patient response to hydroxyurea treatment in underdeveloped countries.</p>","PeriodicalId":72611,"journal":{"name":"Clinical laboratory science : journal of the American Society for Medical Technology","volume":"25 4","pages":"212-8"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A method of HbF determination for potential use in underdeveloped countries.\",\"authors\":\"Sarah N Schumacher, Tim R Randolph\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The objective of this study was to develop a simple, cost-effective method of HbF determination potentially useable in underdeveloped countries to determine sickle cell patient response to hydroxyurea treatment. Normal adult blood (HbA), cord blood (HbF), and a 50:50 mixture (HbA+F) were the three sample types used in procedure development. Normal blood samples were collected from the research team, and de-identified cord blood samples were provided by Cardinal Glennon Pediatric Research Institute, St. Louis, MO. The hematocrit of all blood samples was standardized to 35%. The method, based on the Kleihauer-Betke (K-B) test principle, used a citrate solution to selectively elute HbA from RBCs while HbF remained intracellular, and spectrophotometric absorbance of the eluate was the primary outcome measure. A procedure was developed and optimized utilizing a 395 nm wavelength, 30 sec centrifugation time, 6 min incubation time, 20 microL blood volume, and 0.07 M sodium citrate in a 0.06 M sodium phosphate buffer solution. Reproducibility was demonstrated (N = 39) with a mean HbA absorbance of 1.285 (SD 0.069), mean HbA+F absorbance of 0.690 (SD 0.050), and mean HbF absorbance of 0.035 (SD 0.005), also exhibiting linearity (r2 = 0.99). This simple, cost-effective method of HbF determination shows potential as a basis for determining sickle cell patient response to hydroxyurea treatment in underdeveloped countries.</p>\",\"PeriodicalId\":72611,\"journal\":{\"name\":\"Clinical laboratory science : journal of the American Society for Medical Technology\",\"volume\":\"25 4\",\"pages\":\"212-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical laboratory science : journal of the American Society for Medical Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical laboratory science : journal of the American Society for Medical Technology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A method of HbF determination for potential use in underdeveloped countries.
The objective of this study was to develop a simple, cost-effective method of HbF determination potentially useable in underdeveloped countries to determine sickle cell patient response to hydroxyurea treatment. Normal adult blood (HbA), cord blood (HbF), and a 50:50 mixture (HbA+F) were the three sample types used in procedure development. Normal blood samples were collected from the research team, and de-identified cord blood samples were provided by Cardinal Glennon Pediatric Research Institute, St. Louis, MO. The hematocrit of all blood samples was standardized to 35%. The method, based on the Kleihauer-Betke (K-B) test principle, used a citrate solution to selectively elute HbA from RBCs while HbF remained intracellular, and spectrophotometric absorbance of the eluate was the primary outcome measure. A procedure was developed and optimized utilizing a 395 nm wavelength, 30 sec centrifugation time, 6 min incubation time, 20 microL blood volume, and 0.07 M sodium citrate in a 0.06 M sodium phosphate buffer solution. Reproducibility was demonstrated (N = 39) with a mean HbA absorbance of 1.285 (SD 0.069), mean HbA+F absorbance of 0.690 (SD 0.050), and mean HbF absorbance of 0.035 (SD 0.005), also exhibiting linearity (r2 = 0.99). This simple, cost-effective method of HbF determination shows potential as a basis for determining sickle cell patient response to hydroxyurea treatment in underdeveloped countries.