{"title":"心房起搏治疗预防植入式除颤器患者心房颤动。","authors":"Anne M Gillis","doi":"10.1023/B:CEPR.0000023135.19859.6d","DOIUrl":null,"url":null,"abstract":"<p><p>Atrial fibrillation (AF), atrial flutter and atrial tachycardia (AT) occur frequently in patients following implantation of an implantable cardioverter defibrillator (ICD) for the treatment of ventricular tachyarrhythmias. Some new generation ICDs have incorporated atrial antitachycardia pacing therapy (ATP) and atrial pacing algorithms designed specifically for the prevention of AF. In the GEM III AT clinical evaluation, atrial ATP efficacy for termination of AF and AT was assessed. Overall ATP efficacy for AF/AT, based on device classification, was 40% when adjusted using the Generalized Estimating Equations to account for correlated data that arises from utilizing multiple episodes in some patients. However, many episodes of AF/AT were noted to terminate within 10 minutes of onset. Applying a more conservative definition of efficacy, termination within 20 sec of delivery of the last atrial ATP, efficacy for termination of AF/AT was 26%. 50 Hz burst pacing was shown to have minimal efficacy for termination of AF and modest incremental benefit following ramp or burst pacing therapies for AT. These observations provide a more realistic expectation of the value of atrial ATP in the ICD population with AF. Atrial ATP terminates some episodes of AT but previously reported efficacy rates of 40-50% are exaggerated and in part reflect spontaneous terminations of some AF/AT episodes.</p>","PeriodicalId":80888,"journal":{"name":"Cardiac electrophysiology review","volume":"7 4","pages":"345-7"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/B:CEPR.0000023135.19859.6d","citationCount":"1","resultStr":"{\"title\":\"Atrial pacing therapies for prevention of atrial fibrillation in patients with implantable defibrillators.\",\"authors\":\"Anne M Gillis\",\"doi\":\"10.1023/B:CEPR.0000023135.19859.6d\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Atrial fibrillation (AF), atrial flutter and atrial tachycardia (AT) occur frequently in patients following implantation of an implantable cardioverter defibrillator (ICD) for the treatment of ventricular tachyarrhythmias. Some new generation ICDs have incorporated atrial antitachycardia pacing therapy (ATP) and atrial pacing algorithms designed specifically for the prevention of AF. In the GEM III AT clinical evaluation, atrial ATP efficacy for termination of AF and AT was assessed. Overall ATP efficacy for AF/AT, based on device classification, was 40% when adjusted using the Generalized Estimating Equations to account for correlated data that arises from utilizing multiple episodes in some patients. However, many episodes of AF/AT were noted to terminate within 10 minutes of onset. Applying a more conservative definition of efficacy, termination within 20 sec of delivery of the last atrial ATP, efficacy for termination of AF/AT was 26%. 50 Hz burst pacing was shown to have minimal efficacy for termination of AF and modest incremental benefit following ramp or burst pacing therapies for AT. These observations provide a more realistic expectation of the value of atrial ATP in the ICD population with AF. Atrial ATP terminates some episodes of AT but previously reported efficacy rates of 40-50% are exaggerated and in part reflect spontaneous terminations of some AF/AT episodes.</p>\",\"PeriodicalId\":80888,\"journal\":{\"name\":\"Cardiac electrophysiology review\",\"volume\":\"7 4\",\"pages\":\"345-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1023/B:CEPR.0000023135.19859.6d\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiac electrophysiology review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1023/B:CEPR.0000023135.19859.6d\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiac electrophysiology review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/B:CEPR.0000023135.19859.6d","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
心房颤动(AF)、心房扑动和心房心动过速(AT)在植入式心律转复除颤器(ICD)治疗室性心动过速后经常发生。一些新一代icd纳入了心房抗心动过速起搏治疗(ATP)和专门为预防房颤而设计的心房起搏算法。在GEM III AT临床评估中,评估了心房ATP对房颤和房颤终止的疗效。当使用广义估计方程(Generalized estimation Equations)来考虑某些患者多次发作所产生的相关数据时,基于器械分类的AF/AT的总ATP疗效为40%。然而,许多AF/AT发作在发病10分钟内结束。如果采用更为保守的疗效定义,即在最后一次心房ATP递送20秒内终止,则AF/AT终止的有效率为26%。50hz猝发起搏对房颤终止的疗效最小,而对AT的斜坡或猝发起搏治疗的益处增加不大。这些观察结果为心房ATP在患有房颤的ICD人群中的价值提供了更现实的预期。心房ATP终止一些房颤发作,但先前报道的40-50%的有效率被夸大了,部分反映了一些房颤/房颤发作的自发终止。
Atrial pacing therapies for prevention of atrial fibrillation in patients with implantable defibrillators.
Atrial fibrillation (AF), atrial flutter and atrial tachycardia (AT) occur frequently in patients following implantation of an implantable cardioverter defibrillator (ICD) for the treatment of ventricular tachyarrhythmias. Some new generation ICDs have incorporated atrial antitachycardia pacing therapy (ATP) and atrial pacing algorithms designed specifically for the prevention of AF. In the GEM III AT clinical evaluation, atrial ATP efficacy for termination of AF and AT was assessed. Overall ATP efficacy for AF/AT, based on device classification, was 40% when adjusted using the Generalized Estimating Equations to account for correlated data that arises from utilizing multiple episodes in some patients. However, many episodes of AF/AT were noted to terminate within 10 minutes of onset. Applying a more conservative definition of efficacy, termination within 20 sec of delivery of the last atrial ATP, efficacy for termination of AF/AT was 26%. 50 Hz burst pacing was shown to have minimal efficacy for termination of AF and modest incremental benefit following ramp or burst pacing therapies for AT. These observations provide a more realistic expectation of the value of atrial ATP in the ICD population with AF. Atrial ATP terminates some episodes of AT but previously reported efficacy rates of 40-50% are exaggerated and in part reflect spontaneous terminations of some AF/AT episodes.