声场辅助水相聚合物体系的脱混。

N D Srinivas, N Nagaraj, K S Raghavarao
{"title":"声场辅助水相聚合物体系的脱混。","authors":"N D Srinivas,&nbsp;N Nagaraj,&nbsp;K S Raghavarao","doi":"10.1023/a:1016357604478","DOIUrl":null,"url":null,"abstract":"<p><p>Acoustic field assisted demixing was employed to decrease the demixing time in polymer-polymer (polyethylene glycol-maltodextrin) two-phase system. Application of acoustic field has decreased the demixing time in these systems up to 2-fold. Ultrasonication has induced mild circulation currents in the phase dispersion, which has enhanced the rate of droplet coalescence, eventually resulting in decreased demixing time. In polymer-polymer systems, phase demixing was found to depend greatly on which of the phases is continuous and viscosity of the continuous phase was observed to have a strong influence on the movement of the droplets and hence the phase demixing. Addition of NaCl increased the demixing time and presence of E. coli cells did not seem to have any influence on phase demixing.</p>","PeriodicalId":9179,"journal":{"name":"Bioseparation","volume":"10 4-5","pages":"203-10"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/a:1016357604478","citationCount":"2","resultStr":"{\"title\":\"Acoustic field assisted demixing of aqueous two-phase polymer systems.\",\"authors\":\"N D Srinivas,&nbsp;N Nagaraj,&nbsp;K S Raghavarao\",\"doi\":\"10.1023/a:1016357604478\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Acoustic field assisted demixing was employed to decrease the demixing time in polymer-polymer (polyethylene glycol-maltodextrin) two-phase system. Application of acoustic field has decreased the demixing time in these systems up to 2-fold. Ultrasonication has induced mild circulation currents in the phase dispersion, which has enhanced the rate of droplet coalescence, eventually resulting in decreased demixing time. In polymer-polymer systems, phase demixing was found to depend greatly on which of the phases is continuous and viscosity of the continuous phase was observed to have a strong influence on the movement of the droplets and hence the phase demixing. Addition of NaCl increased the demixing time and presence of E. coli cells did not seem to have any influence on phase demixing.</p>\",\"PeriodicalId\":9179,\"journal\":{\"name\":\"Bioseparation\",\"volume\":\"10 4-5\",\"pages\":\"203-10\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1023/a:1016357604478\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioseparation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1023/a:1016357604478\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioseparation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/a:1016357604478","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在聚合物-聚合物(聚乙二醇-麦芽糖糊精)两相体系中,采用声场辅助脱混来缩短脱混时间。声场的应用使系统的脱混时间缩短了1 / 2。超声作用在相分散中产生温和的环流,提高了液滴的聚并速度,最终缩短了脱混时间。在聚合物-聚合物体系中,相的分离很大程度上取决于哪一个相是连续的,连续相的粘度对液滴的运动和相的分离有很大的影响。NaCl的加入增加了脱混时间,大肠杆菌细胞的存在似乎对相的脱混没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Acoustic field assisted demixing of aqueous two-phase polymer systems.

Acoustic field assisted demixing was employed to decrease the demixing time in polymer-polymer (polyethylene glycol-maltodextrin) two-phase system. Application of acoustic field has decreased the demixing time in these systems up to 2-fold. Ultrasonication has induced mild circulation currents in the phase dispersion, which has enhanced the rate of droplet coalescence, eventually resulting in decreased demixing time. In polymer-polymer systems, phase demixing was found to depend greatly on which of the phases is continuous and viscosity of the continuous phase was observed to have a strong influence on the movement of the droplets and hence the phase demixing. Addition of NaCl increased the demixing time and presence of E. coli cells did not seem to have any influence on phase demixing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信