无骨水泥人工髋关节植入后的放射学改变。无骨水泥人工髋关节5年随访及临床经验[j]。

Aktuelle Radiologie Pub Date : 1998-09-01
K Wilhelm, R Conrad, H Reich, H Zieger, H Schild
{"title":"无骨水泥人工髋关节植入后的放射学改变。无骨水泥人工髋关节5年随访及临床经验[j]。","authors":"K Wilhelm,&nbsp;R Conrad,&nbsp;H Reich,&nbsp;H Zieger,&nbsp;H Schild","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate early reliable radiographic signs of loosening in cementless total hip arthroplasty compared to clinical follow-up.</p><p><strong>Methods: </strong>Within a time interval of 5 years 89 patients with 101 hips underwent total hip arthroplasty using the Autophor 900 S-prosthesis. Clinical and radiographic follow-up were first performed retrospectively followed by a prospective investigation.</p><p><strong>Results: </strong>Radiographic evaluation showed prosthesis fixation in 93%. Loosening of the prosthesis was identified in 4 cases of the acetabular component and in 4 cases of the femoral stem. Pain was associated with radiographically detectable loosening of the cementless arthroplastic components in only two cases.</p><p><strong>Conclusion: </strong>Within a follow-up period of up to five years, loosening of cementless total hip arthroplasty occurs in about 7%. The most reliable radiographic signs of loosening are complete radiolucent zones wider than 2 mm at the bone-component interface, progressive subsidence, migration, or tilt of the component. Pain and movement disorders are not specific symptoms and do not necessarily indicate a loosening of the prosthesis.</p>","PeriodicalId":76986,"journal":{"name":"Aktuelle Radiologie","volume":"8 5","pages":"225-31"},"PeriodicalIF":0.0000,"publicationDate":"1998-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Radiologic changes following cement-free implantation of hip prostheses. 5-year follow-up and clinical experience with the cement-free hip prosthesis Autophor-900-S].\",\"authors\":\"K Wilhelm,&nbsp;R Conrad,&nbsp;H Reich,&nbsp;H Zieger,&nbsp;H Schild\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate early reliable radiographic signs of loosening in cementless total hip arthroplasty compared to clinical follow-up.</p><p><strong>Methods: </strong>Within a time interval of 5 years 89 patients with 101 hips underwent total hip arthroplasty using the Autophor 900 S-prosthesis. Clinical and radiographic follow-up were first performed retrospectively followed by a prospective investigation.</p><p><strong>Results: </strong>Radiographic evaluation showed prosthesis fixation in 93%. Loosening of the prosthesis was identified in 4 cases of the acetabular component and in 4 cases of the femoral stem. Pain was associated with radiographically detectable loosening of the cementless arthroplastic components in only two cases.</p><p><strong>Conclusion: </strong>Within a follow-up period of up to five years, loosening of cementless total hip arthroplasty occurs in about 7%. The most reliable radiographic signs of loosening are complete radiolucent zones wider than 2 mm at the bone-component interface, progressive subsidence, migration, or tilt of the component. Pain and movement disorders are not specific symptoms and do not necessarily indicate a loosening of the prosthesis.</p>\",\"PeriodicalId\":76986,\"journal\":{\"name\":\"Aktuelle Radiologie\",\"volume\":\"8 5\",\"pages\":\"225-31\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Aktuelle Radiologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aktuelle Radiologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价无骨水泥全髋关节置换术中早期可靠的松动影像学征象,并与临床随访进行比较。方法:在5年的时间间隔内,89例101髋采用Autophor 900 s假体进行全髋关节置换术。首先进行回顾性临床和影像学随访,然后进行前瞻性调查。结果:x线检查显示假体固定率为93%。4例髋臼假体松动,4例股骨干假体松动。只有两个病例的疼痛与无骨水泥关节成形术部件的放射学检测到的松动有关。结论:在长达5年的随访期内,无骨水泥全髋关节置换术松动发生率约为7%。松动最可靠的x线征象是骨-构件界面处宽度大于2mm的完全透光区,构件逐渐下沉、迁移或倾斜。疼痛和运动障碍不是特异性症状,也不一定表明假体松动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Radiologic changes following cement-free implantation of hip prostheses. 5-year follow-up and clinical experience with the cement-free hip prosthesis Autophor-900-S].

Purpose: To evaluate early reliable radiographic signs of loosening in cementless total hip arthroplasty compared to clinical follow-up.

Methods: Within a time interval of 5 years 89 patients with 101 hips underwent total hip arthroplasty using the Autophor 900 S-prosthesis. Clinical and radiographic follow-up were first performed retrospectively followed by a prospective investigation.

Results: Radiographic evaluation showed prosthesis fixation in 93%. Loosening of the prosthesis was identified in 4 cases of the acetabular component and in 4 cases of the femoral stem. Pain was associated with radiographically detectable loosening of the cementless arthroplastic components in only two cases.

Conclusion: Within a follow-up period of up to five years, loosening of cementless total hip arthroplasty occurs in about 7%. The most reliable radiographic signs of loosening are complete radiolucent zones wider than 2 mm at the bone-component interface, progressive subsidence, migration, or tilt of the component. Pain and movement disorders are not specific symptoms and do not necessarily indicate a loosening of the prosthesis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信