{"title":"[假体的磨损和松动]。","authors":"F Langlais,&nbsp;J C Lambotte,&nbsp;H Thomazeau,&nbsp;T Dreano","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In 1996, the outcome of any total joint replacement is loosening, occurring usually about 20 years after implantation. Loosening is not a mechanical failure of the bone-implant junction but the consequence of the osteolysis of the periprosthetic bone. It is due to an inflammatory pannus, a tissue constituted by macrophages, which are activated by wear particules originated by the articulating surfaces. The authors showed that this osteolysis is close from that observed with other inflammatory diseases and that it can be obtained with wear particules of many biomaterials, the polyethylene (PE) being the most common in clinical conditions. Several trends in order to reduce polyethylene wear or to replace PE by other materials are presented. Future improvements of the duration of joint prostheses depend on laboratories including surgeons involved in basic research: they are a mandatory link between the engineer and the biologist who study the mechanical and the biological aspects of the wear and of the fixation of biomaterials.</p>","PeriodicalId":10182,"journal":{"name":"Chirurgie; memoires de l'Academie de chirurgie","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1997-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Wear and loosening of prostheses].\",\"authors\":\"F Langlais,&nbsp;J C Lambotte,&nbsp;H Thomazeau,&nbsp;T Dreano\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In 1996, the outcome of any total joint replacement is loosening, occurring usually about 20 years after implantation. Loosening is not a mechanical failure of the bone-implant junction but the consequence of the osteolysis of the periprosthetic bone. It is due to an inflammatory pannus, a tissue constituted by macrophages, which are activated by wear particules originated by the articulating surfaces. The authors showed that this osteolysis is close from that observed with other inflammatory diseases and that it can be obtained with wear particules of many biomaterials, the polyethylene (PE) being the most common in clinical conditions. Several trends in order to reduce polyethylene wear or to replace PE by other materials are presented. Future improvements of the duration of joint prostheses depend on laboratories including surgeons involved in basic research: they are a mandatory link between the engineer and the biologist who study the mechanical and the biological aspects of the wear and of the fixation of biomaterials.</p>\",\"PeriodicalId\":10182,\"journal\":{\"name\":\"Chirurgie; memoires de l'Academie de chirurgie\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chirurgie; memoires de l'Academie de chirurgie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chirurgie; memoires de l'Academie de chirurgie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

1996年,任何全关节置换术的结果都是松动,通常发生在植入后20年左右。松动不是骨-种植体连接处的机械故障,而是假体周围骨溶解的结果。这是由于炎性膜,一种由巨噬细胞组成的组织,被关节表面产生的磨损颗粒激活。作者表明,这种骨溶解与其他炎症性疾病中观察到的骨溶解接近,并且可以通过许多生物材料的磨损颗粒获得,聚乙烯(PE)是临床上最常见的。提出了减少聚乙烯磨损或用其他材料代替聚乙烯的几种趋势。关节假体持续时间的未来改进取决于包括参与基础研究的外科医生在内的实验室:它们是工程师和研究磨损和生物材料固定的机械和生物方面的生物学家之间的强制性联系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Wear and loosening of prostheses].

In 1996, the outcome of any total joint replacement is loosening, occurring usually about 20 years after implantation. Loosening is not a mechanical failure of the bone-implant junction but the consequence of the osteolysis of the periprosthetic bone. It is due to an inflammatory pannus, a tissue constituted by macrophages, which are activated by wear particules originated by the articulating surfaces. The authors showed that this osteolysis is close from that observed with other inflammatory diseases and that it can be obtained with wear particules of many biomaterials, the polyethylene (PE) being the most common in clinical conditions. Several trends in order to reduce polyethylene wear or to replace PE by other materials are presented. Future improvements of the duration of joint prostheses depend on laboratories including surgeons involved in basic research: they are a mandatory link between the engineer and the biologist who study the mechanical and the biological aspects of the wear and of the fixation of biomaterials.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信