两种新的长距离立体测试:关于驾驶许可的立体视觉检查。

German journal of ophthalmology Pub Date : 1996-01-01
R Fleck, G H Kolling
{"title":"两种新的长距离立体测试:关于驾驶许可的立体视觉检查。","authors":"R Fleck,&nbsp;G H Kolling","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Two differently constructed stereotests for a distance of 4 m are presented (tests A and B), which are based on the three-rod method of Helmholtz. In both tests, eight test objects are offered simultaneously, one of them being displaced toward the subject to a certain extent (100-10 s of arc). In test A the subject sees the eight test objects through eight holes, whereas in test B the test objects are seen directly. Each disparity is offered eight times. The threshold is defined as five of eight answers being correct. A total of 51 subjects without strabismus and with normal stereopsis in conventional tests achieved a mean stereo-acuity of 30 s of arc in test A and 10 s of arc in test B. The same subjects with one eye occluded and 49 patients with severe binocular defects reached chance scores only in test A, whereas in test B the success rate was improved slightly by monocular clues (P = 1/5). In examining stereopsis with regard to driving licenses, only tests for long distance should be used. Both new stereotests differentiate between normal and pathological candidates with high specificity and sensitivity.</p>","PeriodicalId":77146,"journal":{"name":"German journal of ophthalmology","volume":"5 1","pages":"53-9"},"PeriodicalIF":0.0000,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Two new stereotests for long distance: examination of stereopsis with regard to the permission of driving.\",\"authors\":\"R Fleck,&nbsp;G H Kolling\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Two differently constructed stereotests for a distance of 4 m are presented (tests A and B), which are based on the three-rod method of Helmholtz. In both tests, eight test objects are offered simultaneously, one of them being displaced toward the subject to a certain extent (100-10 s of arc). In test A the subject sees the eight test objects through eight holes, whereas in test B the test objects are seen directly. Each disparity is offered eight times. The threshold is defined as five of eight answers being correct. A total of 51 subjects without strabismus and with normal stereopsis in conventional tests achieved a mean stereo-acuity of 30 s of arc in test A and 10 s of arc in test B. The same subjects with one eye occluded and 49 patients with severe binocular defects reached chance scores only in test A, whereas in test B the success rate was improved slightly by monocular clues (P = 1/5). In examining stereopsis with regard to driving licenses, only tests for long distance should be used. Both new stereotests differentiate between normal and pathological candidates with high specificity and sensitivity.</p>\",\"PeriodicalId\":77146,\"journal\":{\"name\":\"German journal of ophthalmology\",\"volume\":\"5 1\",\"pages\":\"53-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"German journal of ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"German journal of ophthalmology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

提出了两种不同构造的距离为4 m的立体试验(试验a和试验B),它们都是基于亥姆霍兹三杆法。在两个测试中,同时提供8个测试对象,其中一个向受试者移位一定程度(100-10秒弧)。在测试A中,受试者通过8个孔看到8个测试对象,而在测试B中,测试对象是直接看到的。每个差距提供8次。临界值定义为8个答案中有5个是正确的。在常规测试中,51名无斜视且立体视觉正常的受试者在测试A和测试B中平均立体视力分别达到30秒弧度和10秒弧度,而在测试A和测试B中,49名双眼严重缺陷的受试者仅在测试A中获得机会得分,而在测试B中,单眼线索的成功率略有提高(P = 1/5)。在检查与驾驶执照有关的立体视觉时,只应使用长距离测试。这两种新的立体试验区分正常和病理候选人具有高特异性和敏感性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Two new stereotests for long distance: examination of stereopsis with regard to the permission of driving.

Two differently constructed stereotests for a distance of 4 m are presented (tests A and B), which are based on the three-rod method of Helmholtz. In both tests, eight test objects are offered simultaneously, one of them being displaced toward the subject to a certain extent (100-10 s of arc). In test A the subject sees the eight test objects through eight holes, whereas in test B the test objects are seen directly. Each disparity is offered eight times. The threshold is defined as five of eight answers being correct. A total of 51 subjects without strabismus and with normal stereopsis in conventional tests achieved a mean stereo-acuity of 30 s of arc in test A and 10 s of arc in test B. The same subjects with one eye occluded and 49 patients with severe binocular defects reached chance scores only in test A, whereas in test B the success rate was improved slightly by monocular clues (P = 1/5). In examining stereopsis with regard to driving licenses, only tests for long distance should be used. Both new stereotests differentiate between normal and pathological candidates with high specificity and sensitivity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信