{"title":"两种新的长距离立体测试:关于驾驶许可的立体视觉检查。","authors":"R Fleck, G H Kolling","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Two differently constructed stereotests for a distance of 4 m are presented (tests A and B), which are based on the three-rod method of Helmholtz. In both tests, eight test objects are offered simultaneously, one of them being displaced toward the subject to a certain extent (100-10 s of arc). In test A the subject sees the eight test objects through eight holes, whereas in test B the test objects are seen directly. Each disparity is offered eight times. The threshold is defined as five of eight answers being correct. A total of 51 subjects without strabismus and with normal stereopsis in conventional tests achieved a mean stereo-acuity of 30 s of arc in test A and 10 s of arc in test B. The same subjects with one eye occluded and 49 patients with severe binocular defects reached chance scores only in test A, whereas in test B the success rate was improved slightly by monocular clues (P = 1/5). In examining stereopsis with regard to driving licenses, only tests for long distance should be used. Both new stereotests differentiate between normal and pathological candidates with high specificity and sensitivity.</p>","PeriodicalId":77146,"journal":{"name":"German journal of ophthalmology","volume":"5 1","pages":"53-9"},"PeriodicalIF":0.0000,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Two new stereotests for long distance: examination of stereopsis with regard to the permission of driving.\",\"authors\":\"R Fleck, G H Kolling\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Two differently constructed stereotests for a distance of 4 m are presented (tests A and B), which are based on the three-rod method of Helmholtz. In both tests, eight test objects are offered simultaneously, one of them being displaced toward the subject to a certain extent (100-10 s of arc). In test A the subject sees the eight test objects through eight holes, whereas in test B the test objects are seen directly. Each disparity is offered eight times. The threshold is defined as five of eight answers being correct. A total of 51 subjects without strabismus and with normal stereopsis in conventional tests achieved a mean stereo-acuity of 30 s of arc in test A and 10 s of arc in test B. The same subjects with one eye occluded and 49 patients with severe binocular defects reached chance scores only in test A, whereas in test B the success rate was improved slightly by monocular clues (P = 1/5). In examining stereopsis with regard to driving licenses, only tests for long distance should be used. Both new stereotests differentiate between normal and pathological candidates with high specificity and sensitivity.</p>\",\"PeriodicalId\":77146,\"journal\":{\"name\":\"German journal of ophthalmology\",\"volume\":\"5 1\",\"pages\":\"53-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"German journal of ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"German journal of ophthalmology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Two new stereotests for long distance: examination of stereopsis with regard to the permission of driving.
Two differently constructed stereotests for a distance of 4 m are presented (tests A and B), which are based on the three-rod method of Helmholtz. In both tests, eight test objects are offered simultaneously, one of them being displaced toward the subject to a certain extent (100-10 s of arc). In test A the subject sees the eight test objects through eight holes, whereas in test B the test objects are seen directly. Each disparity is offered eight times. The threshold is defined as five of eight answers being correct. A total of 51 subjects without strabismus and with normal stereopsis in conventional tests achieved a mean stereo-acuity of 30 s of arc in test A and 10 s of arc in test B. The same subjects with one eye occluded and 49 patients with severe binocular defects reached chance scores only in test A, whereas in test B the success rate was improved slightly by monocular clues (P = 1/5). In examining stereopsis with regard to driving licenses, only tests for long distance should be used. Both new stereotests differentiate between normal and pathological candidates with high specificity and sensitivity.