M P Kalandarova, V V Poliakov, I B Goncharov, L Iu Tikhonova
{"title":"[宇航员在太空飞行中的血液学参数]。","authors":"M P Kalandarova, V V Poliakov, I B Goncharov, L Iu Tikhonova","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This paper present hematological data obtained during space flights of the third and the fourth prime crew flights (EO-3 and EO-4). In the EO-3 flight, RBCs, WBCs and blood formed elements were counted by the cosmonaut-researcher. In the EO-4 flight, blood was drawn by the cosmonaut-researcher and analyzed on the ground; also, blood smears treated in the Microview unit and videotaped were used. Blood parameters in EO-3 and EO-4 crewmembers were close or equal to the normal. However there were cases with changes in bends, myelocytes, neutrophils, lymphocytes; also anisocytosis, hypochromia, target-like erythrocytes, and single acanthocytes were seen. Comparison of blood smears on unstained and stained glass slides revealed significant differences in the amount of target-like erythrocytes in the same cosmonaut at the same time (on the prestained glass slide only 4 erythrocytes and no aggregates in single fields of vision were detected while on the unstained glass slide aggregates in single fields of vision were seen). Pre- and postflight examinations of bone marrow revealed polymorphocellular marrow and mature hemopoietic cells.</p>","PeriodicalId":76078,"journal":{"name":"Kosmicheskaia biologiia i aviakosmicheskaia meditsina","volume":"25 6","pages":"11-4"},"PeriodicalIF":0.0000,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Hematological parameters of cosmonauts during space flight].\",\"authors\":\"M P Kalandarova, V V Poliakov, I B Goncharov, L Iu Tikhonova\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This paper present hematological data obtained during space flights of the third and the fourth prime crew flights (EO-3 and EO-4). In the EO-3 flight, RBCs, WBCs and blood formed elements were counted by the cosmonaut-researcher. In the EO-4 flight, blood was drawn by the cosmonaut-researcher and analyzed on the ground; also, blood smears treated in the Microview unit and videotaped were used. Blood parameters in EO-3 and EO-4 crewmembers were close or equal to the normal. However there were cases with changes in bends, myelocytes, neutrophils, lymphocytes; also anisocytosis, hypochromia, target-like erythrocytes, and single acanthocytes were seen. Comparison of blood smears on unstained and stained glass slides revealed significant differences in the amount of target-like erythrocytes in the same cosmonaut at the same time (on the prestained glass slide only 4 erythrocytes and no aggregates in single fields of vision were detected while on the unstained glass slide aggregates in single fields of vision were seen). Pre- and postflight examinations of bone marrow revealed polymorphocellular marrow and mature hemopoietic cells.</p>\",\"PeriodicalId\":76078,\"journal\":{\"name\":\"Kosmicheskaia biologiia i aviakosmicheskaia meditsina\",\"volume\":\"25 6\",\"pages\":\"11-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kosmicheskaia biologiia i aviakosmicheskaia meditsina\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kosmicheskaia biologiia i aviakosmicheskaia meditsina","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Hematological parameters of cosmonauts during space flight].
This paper present hematological data obtained during space flights of the third and the fourth prime crew flights (EO-3 and EO-4). In the EO-3 flight, RBCs, WBCs and blood formed elements were counted by the cosmonaut-researcher. In the EO-4 flight, blood was drawn by the cosmonaut-researcher and analyzed on the ground; also, blood smears treated in the Microview unit and videotaped were used. Blood parameters in EO-3 and EO-4 crewmembers were close or equal to the normal. However there were cases with changes in bends, myelocytes, neutrophils, lymphocytes; also anisocytosis, hypochromia, target-like erythrocytes, and single acanthocytes were seen. Comparison of blood smears on unstained and stained glass slides revealed significant differences in the amount of target-like erythrocytes in the same cosmonaut at the same time (on the prestained glass slide only 4 erythrocytes and no aggregates in single fields of vision were detected while on the unstained glass slide aggregates in single fields of vision were seen). Pre- and postflight examinations of bone marrow revealed polymorphocellular marrow and mature hemopoietic cells.