右旋糖酐的分析凝胶过滤研究肾小球屏障功能。

L Hagel, A Hartmann, K Lund
{"title":"右旋糖酐的分析凝胶过滤研究肾小球屏障功能。","authors":"L Hagel,&nbsp;A Hartmann,&nbsp;K Lund","doi":"10.1016/0021-9673(93)83459-6","DOIUrl":null,"url":null,"abstract":"<p><p>Analytical gel filtration was used for the study of molecular size distribution of clinical dextran in serum and urine for the purpose of evaluations of changes in the human glomerular barrier function. The column was calibrated in terms of solute size using a simple and accurate technique recently described. Only one sample of a dextran possessing a broad molecular mass distribution was necessary for the calibration procedure and the calculations were performed using an ordinary spreadsheet. The accuracy of the calibration, as evaluated by protein samples, is better than 95%. The simplicity makes the method suitable for use in laboratories not normally specializing in analytical gel filtration. Calibration in terms of size is preferably done with respect to viscosity radius to obtain relevant information about the permeability of dextran into porous membranes.</p>","PeriodicalId":15508,"journal":{"name":"Journal of chromatography","volume":"641 1","pages":"63-70"},"PeriodicalIF":0.0000,"publicationDate":"1993-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0021-9673(93)83459-6","citationCount":"10","resultStr":"{\"title\":\"Analytical gel filtration of dextran for the study of the glomerular barrier function.\",\"authors\":\"L Hagel,&nbsp;A Hartmann,&nbsp;K Lund\",\"doi\":\"10.1016/0021-9673(93)83459-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Analytical gel filtration was used for the study of molecular size distribution of clinical dextran in serum and urine for the purpose of evaluations of changes in the human glomerular barrier function. The column was calibrated in terms of solute size using a simple and accurate technique recently described. Only one sample of a dextran possessing a broad molecular mass distribution was necessary for the calibration procedure and the calculations were performed using an ordinary spreadsheet. The accuracy of the calibration, as evaluated by protein samples, is better than 95%. The simplicity makes the method suitable for use in laboratories not normally specializing in analytical gel filtration. Calibration in terms of size is preferably done with respect to viscosity radius to obtain relevant information about the permeability of dextran into porous membranes.</p>\",\"PeriodicalId\":15508,\"journal\":{\"name\":\"Journal of chromatography\",\"volume\":\"641 1\",\"pages\":\"63-70\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-07-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0021-9673(93)83459-6\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of chromatography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1016/0021-9673(93)83459-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/0021-9673(93)83459-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

采用分析凝胶过滤法研究临床右旋糖酐在血清和尿液中的分子大小分布,以评价人肾小球屏障功能的变化。用一种简单而准确的技术对溶质大小进行校准。校准过程只需要一个具有广泛分子质量分布的葡聚糖样品,并且使用普通电子表格进行计算。经蛋白质样品评估,校准的准确度优于95%。简单性使该方法适用于通常不专门从事分析凝胶过滤的实验室。最好根据粘度半径进行尺寸校准,以获得有关葡聚糖进入多孔膜的渗透性的相关信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analytical gel filtration of dextran for the study of the glomerular barrier function.

Analytical gel filtration was used for the study of molecular size distribution of clinical dextran in serum and urine for the purpose of evaluations of changes in the human glomerular barrier function. The column was calibrated in terms of solute size using a simple and accurate technique recently described. Only one sample of a dextran possessing a broad molecular mass distribution was necessary for the calibration procedure and the calculations were performed using an ordinary spreadsheet. The accuracy of the calibration, as evaluated by protein samples, is better than 95%. The simplicity makes the method suitable for use in laboratories not normally specializing in analytical gel filtration. Calibration in terms of size is preferably done with respect to viscosity radius to obtain relevant information about the permeability of dextran into porous membranes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信